• Title/Summary/Keyword: 고층

Search Result 1,322, Processing Time 0.03 seconds

A Study on Occurrence Frequency of Cloud for Altitude in the Central Region of the Korean Peninsula using Upper-Air Observation Data (고층기상관측자료를 이용한 한반도 중부지방의 고도별 구름 발생빈도 연구)

  • Kim, In Yong;Park, Hyeryeong;Kim, Min Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.716-723
    • /
    • 2019
  • It is crucial to understand the characteristics of cloud occurrence frequency for development of high precision guided missile using infrared imaging sensor. In this paper, we investigated the vertical structure of cloud for altitude using upper-air observation data. We find that cloud occurrence frequency is high at altitudes of 1.3 km and 9.5 km. Theses features have seasonal and temporal dependency. In the summer, cloud often occur more than average regardless of altitude. In the winter, low clouds occur frequently, and high clouds do not occur well. In temporal characteristics, clouds occur more frequently in daytime than in nighttime regardless of altitude. Many of clouds exist in single layer or double layers in the air. We also find that the 40 % of cloud occurrence frequency at high altitude when low clouds under altitude of 2 km cover entire sky.

A Study on The Radar QPE Improvement Technique Using Rapid RHI Volume Scan (RHI 볼륨자료를 이용한 레이더 QPE 정확도 향상 기법 연구)

  • Hwang, Seok Hwan;Oh, Byung Hwa;Cho, Hyo Seob;Lee, Dong Ryul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.18-18
    • /
    • 2016
  • 최근 지구온난화의 영향으로 수 십분 만에 위험상황에 도달하는 돌발성 도시 집중호우가 빈발하고 이로 인한 피해가 급증하면서 기존 지상우량계 및 대형레이더 기반 도시홍수 관측체계에 대한 보완이 필요하게 되었다. 빠르고 정확한 도시홍수의 예측 및 예보를 위해서는 대형레이더 관측범위 이하의 빠른 저고도 관측이 필수이다. 이의 일환으로 우리나라에서도 소형 이중편파 X밴드 레이더를 도입하기 시작하였고 활용에 대한 연구가 시작단계에 있다. 일반적으로 소형레이더의 경우 빠른 운용이 가능하고 집중호우 관측과 같은 특정 목적에서 운영하기 때문에 도시 돌발홍수 예보를 위한 충분한 시간해상도의 자료 생산이 가능하다. 그러나 소형레이더를 이용하여 관측하더라도 고층 아파트나 빌딩이 밀집되어 있는 우리나라 도심 환경에서 관측반경내 전반에 대한 1km 이하 저고도 관측은 물리적으로 매우 어려운 현실이다. 따라서 본 연구에서는 한국건설기술연구원의 X밴드 이중편파 레이더로 관측된 다수의 연직 관측자료를 활용하여 호우의 연직 분포를 3차원으로 재생성한 후 이의 평균 단면 추세를 이용하여 관측고도 이하의 관측치를 추정하는 기법을 개발하였다. 기법의 적합성 평가를 위해 2013년, 2014년 주요 호우 사상에 대해 적용하였고, 검토결과 본 방법을 적용한 경우의 QPE가 기존 관측고도각을 이용한 QPE에 비해 정확도가 향상되는 것으로 나타났다.

  • PDF

Voice Recognition Sensor Driven Elevator for High-rise Vertical Shift (동굴관광용 고층수직이동 승강기의 긴급 음성구동 제어)

  • Choi, Byong-Seob;Kang, Tae-Hyun;Yun, Yeo-Hoon;Jang, Hoon-Gyou;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.88
    • /
    • pp.1-7
    • /
    • 2008
  • Recently, it is one of very interest technology of Human Computer Interaction(HCI). Nowadays, it is easy to find out that, for example, inside SF movies people has talking to computer. However, there are difference between CPU language and ours. So, we focus on connecting to CPU. For 30 years many scientists experienced in that technology. But it is really difficult. Our project goal is making that CPU could understand human voice. First of all the signal through a voice sensor will move to BCD (binary code). That elevator helps out people who wants to move up and down. This product's point is related with people's safety. Using a PWM for motor control by ATmega16, we choose a DC motor to drive it because of making a regular speed elevator. Furthermore, using a voice identification module the elevator driven by voice sensor could operate well up and down perfectly from 1st to 10th floor by PWM control with ATmega16. And, it will be clearly useful for high-rise vertical shift with voice recognition sensor driven.

Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method (T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석)

  • 문종선;강석윤;이승철;유호선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.

Distribution of vascular plant in Mt. Cheonsung, Yangsan (양산 천성산지역 관속식물의 분포)

  • Shin, Hyun-Tak;Lee, Jae-Yoon
    • Korean Journal of Plant Resources
    • /
    • v.22 no.2
    • /
    • pp.180-194
    • /
    • 2009
  • 588 taxa of vascular plants including 121 families, 399 genera, 510 species, 67 varieties, 2 subspecies, 7 forma, and 2 hybrid species were investigated in Mt. Cheonsung. Among them, 116 species were newly added in this research. The area for Gyeongbu High-speed Railway passes Mujechi 3, 4, 5, and 6 and Daeseongsa around the wetlands were investigated 6 species of rare and endangered plants, 9 species of endemic plants and 37 species of special flora plants in Mt. Cheonsung. Appear due to the construction of the Gyeongbu High-speed Railway vegetation changes, especially about the impact of wetland plants for long-term monitoring is expected to need. Moreover, plant preservation plan about water source change in upper wetland should be established.

Analysis of the Upper-Air Temperature Condition for Weapon System Operating in the Korean Peninsula (한반도 지역의 고층대기에서 운용되는 무기체계를 위한 기온 조건 분석)

  • Kim, Hyun-myung;Kang, Dong-sik;Yang, Won-seok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.141-149
    • /
    • 2019
  • This study analyzed upper-air temperatures in order to make temperature conditions for weapon system operating in Korean Peninsula. One of important tasks of environmental analysis is to set-up suitable temperature conditions for successful development of weapon system. Many weapon system developers are setting air temperature conditions based on the MIL-STD-810G. However, for weapons systems that are used only in the upper-air of the Korean Peninsula, the air temperature conditions recommended by MIL-STD-810G are often not suitable. To establish the air temperature conditions for upper-air in the Korean Peninsula, the method of Percentage of Occurrence should has be built up as method of temperature analysis. Upper-air climate data of the Korea Peninsulas over the past decade is also analyzed based on this method. The study suggest upper-air temperature conditions for weapons systems that are operated only in the Korean peninsula.

Performance Evaluation of Wind Response Control of High-Rise Buildings by Damping and Stiffness of Outrigger Damper System (아웃리거 댐퍼시스템의 감쇠와 강성에 따른 고층 건물 풍응답 제어 성능 평가)

  • Park, Kwang-Seob;Kim, Yun-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.41-48
    • /
    • 2018
  • Recently, the concept of an outrigger damper system with a damper added to the existing outrigger system has been developed and applied for dynamic response control of high-rise buildings. However, the study on the structural characteristics and design method of Outrigger damper system is in the early stages. In this study, a 50 story high - rise building was designed and an outrigger damper system with viscoelastic damper was applied for wind response control. The time history analysis was performed by using the kaimal spectrum to create an artificial wind load for a total of 1,000 seconds at 0.1 second intervals. Analysis of the top horizontal maximum displacement response and acceleration response shows that outrigger damper systems are up to 28.33% and 49.26% more effective than conventional outrigger systems, respectively. Also, it is confirmed that the increase of damping ratio of dampers is effective for dynamic response control. However, since increasing the damping capacity increases the economic burden, it is necessary to select the appropriate stiffness and damping value of the outrigger damper system.

Smart elevator operation management mobile application design using clustering techniques (클러스터링 기법을 이용한 스마트 엘리베이터 운영관리 모바일 어플리케이션 설계)

  • Park, Hung-Bog;Son, Gwan-yeong;Choi, Geum-kang;Hwang, You-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.661-662
    • /
    • 2016
  • It's being a trend that contemporary buildings are getting higher. And in line with this, we suggest the smart elevator operation management mobile application which is designed using clustering techniques to improve user's elevator access control and convenience. This clustering technique using the elevator's calling data make it possible to find its best position, and know the state of it using a smart phone as well. With this, not only the users' waiting time can be decreased, but also their convenience can be improved with the remote control system that got efficient a lot.

  • PDF

Seismic Response Control of Tilted Tall Building based on Evolutionary Optimization Algorithm (경사진 고층건물의 진화최적화 알고리즘에 기반한 지진응답 제어)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.3
    • /
    • pp.43-50
    • /
    • 2021
  • A tilted tall building is actively constructed as landmark structures around world to date. Because lateral displacement responses of a tilted tall building occurs even by its self-weight, reduction of seismic responses is very important to ensure structural safety. In this study, a smart tuned mass damper (STMD) was applied to the example tilted tall building and its seismic response control performance was investigated. The STMD was composed of magnetorheological (MR) damper and it was installed on the top floor of the example building. Control performance of the STMD mainly depends on the control algorithn. Fuzzy logic controller (FLC) was selected as a control algorithm for the STMD. Because composing fuzzy rules and tuning membership functions of FLC are difficult task, evolutionary optimization algorithm (EOA) was used to develop the FLC. After numerical simulations, it has been seen that the STMD controlled by the EOA-optimized FLC can effectively reduce seismic responses fo the tilted tall building.

Analysis of the Static Characteristics of High-Rise Structures With Twisted Shape (비틀어진 형상(Twisted)을 가지는 고층 구조물의 역학적 특성 분석)

  • Lee, Da-Hye;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.93-100
    • /
    • 2020
  • In this study, structural characteristics were analyzed by combining gravity load and lateral loads such as seismic loads through static analysis of example structures, and the static characteristics of the twisted structure according to the plane rotation angle were also analyzed. Example structures were selected as regular structure, and twisted structures; 1.0, 2.0, and 3.0 degree angle of rotation per story, and static analysis was performed by the load combination case 1 and case 2. As a result the story drift ratio of the twisted-shaped structure also increased as the plane rotation angle per story increased. The eccentricity according to the load combination was the highest in the lower stories of all analysis models, and the eccentricity was found to be larger as the rotation angle decreased. The twisted-shaped structure was more responsible for the bending moment of the column than the regular structure, and the vertical member axial force of all analysis models was almost similar.