Estimation of Velocity Pressure Exposure Coefficient using GIS (GIS를 이용한 풍속고도분포계수 산정)

  • Seong, Min-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • As an urbanization is in progress, the change of the planimetric features and topography including high-rise residential buildings commonly occur. The change of the planimetric features and topography causes occurrence of the strong wind and wind speed increase or decrease due to the effect of planimetric features and topography on the windward side even though the wind blows with the same speed. In the design standard, this change by wind speed is defined as the velocity pressure exposure coefficient, the value of coefficient is estimated and reflected by ground surface roughness, but in a reality, ground surface roughness is determined in accordance with the subjective judgement of designer and then the velocity pressure exposure coefficient is estimated, moreover the research and data for classification of ground surface roughness are insufficient. In this paper, we will estimate the velocity pressure exposure coefficient by the quantified method for classifying ground surface roughness by using GIS according to the height of a building targeting area where high-rise residential buildings are built lately. When the structure subjected to wind load is designed, reasonability of design and safety of structure will be more improved by using the estimation method of velocity pressure exposure coefficient presented in this study.

Efficient Dynamic Analysis of High-rise Buildings Having Belt Walls Connected by a Sky-Bridge (스카이브릿지로 연결된 벨트월이 있는 고층건물의 효율적인 동적해석)

  • Lee, Dong-Guen;Kim, Hyun-Su;Yang, Ah-Ram;Ko, Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.231-242
    • /
    • 2009
  • In the design of a sky-bridge, repetitive boundary nonlinear time history analyses are required to accurately predict dynamic behaviors of the connected buildings because the connection systems of a sky-bridge usually have high nonlinearity. If a conventional finite element model for entire high-rise buildings is used for repetitive boundary nonlinear time history analyses, computational efforts could be significant. In this study, an equivalent cantilever model considering the belt-wall effect has been proposed for an efficient dynamic analysis and a performance evaluation of vibration control of high-rise buildings connected by a sky-bridge. To verify the accuracy and efficiency of the proposed equivalent model, boundary nonlinear time history analyses of 49- and 42-story example buildings connected by a sky-bridge have been performed for wind excitation. Based on the analytical results, it has been verified that the proposed equivalent model can provide accurate dynamic responses of building structures connected by a sky-bridge with significantly reduced computational efforts.

Assessment Model for the Safety and Serviceability of Structures using Terrestrial LiDAR (지상라이다를 이용한 구조물의 안전 및 사용성 평가 모델)

  • Lee, Hong-Min;Park, Hyo-Seon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.3 s.22
    • /
    • pp.17-28
    • /
    • 2006
  • Structural health monitoring is important to maintain the safety and serviceability of the structures. The displacement in the structure should be precisely and frequently monitored because it is a direct assessment index indicating its stiffness. However, no practical method has been developed to monitor such displacement precisely, particularly for high-rise buildings and long span bridges because they cannot be easily accessible. To overcome such difficult accessibility, we propose to use a LIDAR system that remotely samples the surface of an object using laser pulses and generates the coordinates of numerous points on the surface. In this study, using terrestrial LiDAR, we develop a novel displacement measuring model for structural health monitoring and perform an indoor experiment to prove its performance.

A Study on Stiffness-based Optimal Design of Tall Plane Frameworks using Composite Member (합성부재를 이용한 고층평면골조의 강성최적설계에 관한 연구)

  • Kim, Ho-Soo;Lee, Han-Joo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.3 s.13
    • /
    • pp.77-84
    • /
    • 2004
  • This study presents an effective stiffness-based optimal technique to control quantitatively lateral drift for tall frameworks using composit member subject to lateral loads. To this end, displacement sensitivity depending on behavior characteristics of tall frameworks is established and approximation concept that preserves the generality of the mathematical programming and can efficiently solve large scale problems is introduced. Specifically, under the 'constant-shape' assumption, resizing techniqe of composite member is developed. Two types of 50 story frameworks are presented to illustrate the features of the quantitative lateral drift control technique proposed in this study.

  • PDF

The Wind Pressure Evaluation on Exterior Wall for High-rise Buildings (고층구조물 외벽의 내풍설계를 위한 풍압평가)

  • Lee Kyu-Ung;Kim Jae-Ung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.63-70
    • /
    • 2005
  • For using narrow site effectively, recently constructions of high-rise buildings have been increased. High-rise buildings are mainly governed by wind loads. Since wind flow Is vaned irregularly, the experimental method such as wind tunnel test is used to evaluate real wind loads. In this study, it is intended to estimate design wind pressure and amounts of material of cladding by AIK recommendations and wind tunnel test. Also, this study includes the investigation of reliability, suitability and economical efficiency in design of cladding of buildings by AIK recommendations and wind tunnel test by comparing and examining various results. Finally, it is concluded that not only AIK recommendations but also wind tunnel test should be considered to get the reasonable wind pressure acting on the cladding of high-rise buildings.

  • PDF

관제구역내 환경변화에 따른 VTS의 대처방안

  • Jeong, Sun-Won;Park, Chan-Gil;Park, Yeong-Gil;Kim, Man-Sik;Kim, Bo-Gyeom;Jo, Yun-Gyeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.354-356
    • /
    • 2015
  • 포항항 관제구역은 2009년 8월 영일만항 개장으로 방파제(길이 5.5km) 신설에 따라 정박지 'S-5'내 조류 및 저질변화로 인해 정박선의 주묘현상이 현저하게 발생하고 있으며, 포항 신항내 고층구조물 신설로 인해 동일 시간대 풍향 풍속등 기상현상이 포항구항 및 영일만항, 호미곶과는 달리 강력하게 발생하여 입 출항선박의 안전에 위험을 초래하고 있다. 이와 같이, 관제구역내 환경변화에 따른 정박선의 현저한 주묘 및 포항 신항내 강력한 풍향 풍속등의 발생이 선박의 안전을 위협하고 있다. 본 연구에서는 관제구역내 환경변화에 따른 해상교통안전의 위험을 줄이기 위한 VTS의 역할 및 대처방안에 대해 모색해 보고자 한다.

  • PDF

High-rise buildings using vibration control devices (제진장치를 이용한 고층건물)

  • 민경원
    • Computational Structural Engineering
    • /
    • v.4 no.4
    • /
    • pp.10-13
    • /
    • 1991
  • 현대의 건물은 초고층화 되어가기 때문에 바람이나 지진에 의한 건물의 과다진동이 일어나며 이것은 기초분리(base isolation) 방법 또는 제진장치를 설치함으로써 해결할 수가 있다. 기초분리 방법은 지진 다발 지역에서 지진에 의한 피해를 감소시키기 위하여 주로 이용되며 제진장치는 지진은 물론 바람을 받는 고층건물, 타워, 다리 등의 대형 구조물의 제진에 사용이 되며 병원, 컴퓨터센터, 그리고 반도체 공장 등 정밀한 작업이 이루어지는 곳에서의 국부적인 제진에 적용이 되고 있다. 제진장치는 수동제진장치와 능동제진장치로 대별이 되며 원리는 질량을 이용한 건물의 감쇠력을 증대시키는 데 있다. 능동제진장치를 이용한 시스템은 과다한 설치비와 운영비 뿐만 아니라 강한 바람이나 지진이 왔을 때 전력 중단이 되어 작동이 되지 않을 때가 있으므로 현재로서는 수동제진장치가 많이 이용이 되고 있다. 따라서 현재 강한 바람이나 지진에 대한 건물전체의 거동은 수동제진장치에 의하여 대처하고 약한 바람과 지진 등에 대한 국부적인 제진에는 능동제진장치를 이용하는 복합제진시스템(hybrid vibration control system)이 제시되고 있다.

  • PDF

철근 콘크리트 구조물의 화재조사ㆍ진단방법 및 유지관리방안(일본 콘크리리트공학협회 기준을 중심으로)

  • 권영진;이차돈;홍성걸;신영수;이경구
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.40-46
    • /
    • 2002
  • 산업화 도시화에 따른 건축물의 밀집과 고층화의 환경에서 화재 재해 발생은 인명피해 및 재산피해에 치명적인 결과를 가져올 수 있으며 화재로 인한 인명 및 재산 피해는 두말할 것도 없이 막대한 국가적 손실을 초래한다고 할 수 있다. 따라서 화재발생을 사전에 억제하는 구조물의 방화ㆍ내화구조 및 피난계획, 소화설비 소화활동설비 등에 대한 방재 연구와 더불어 화재발생후 화재의 원인조사와 구조물의 재사용 여부 또는 보강 필요성, 자산의 평가의 과학적인 근거를 위해 신뢰성 있는 안전성 평가에 대한 연구가 필요한 실정이다.(중략)

Mock-Up Test for the Concrete Filled Rectangular Steel Tube Columns of 22 m height with Flowable Concrete (고유동 콘크리트를 사용한 22 m 콘크리트 충전 각형강관기둥의 시공성능실험)

  • 안종문;신성우;전상우;김진호
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.88-95
    • /
    • 2002
  • 최근 국내에 60층을 초과하는 초고층 구조물들이 많이 건설되고 있으며, 콘크리트 품질의 향상 특히 콘크리트의 고강도화에 힘입어 이를 이용한 철근 콘크리트 고층 구조물들이 증가하고 있다. 이에 따라 이들 초고층, 초대형 구조물을 지지할 수 있는 고축력, 고연성의 기둥에 대한 설계 및 시공이 요구되고 있으며, 이에 가장 적합한 구조요소라 할 수 있는 콘크리트 충전 강관기둥(Concrete Filled Steel Tube Columns : CFT Columns)의 설계 및 시공에 관심이 높아지고 있다. 이러한 콘크리트 충전 강관기둥은 콘크리트가 강관에 의해 둘러싸여지기 때문에 축하중 저항 능력이 증가되는 장점과 동일한 단면으로 H형강을 사용한 순수 철골조 H형강 기둥의 강축(strong axis)과 약축(weak axis) 문제해결과 동시에 강성 (stiffness)을 증가시킬 수 있으며, 내화 성능이 향상되고 거푸집 대체 재료로 사용되는 등 여러 가지 장점을 지니고 있다. 한편 충전 강관기둥에 작용하는 축하중은 대부분 콘크리트가 부담하게 되는데 이러한 충전강관 기둥의 장점을 극대화하기 위해서는 보통강도 콘크리트보다는 압축강도 및 탄성계수가 큰 고강도 콘크리트의 사용은 불가피하게 된다.(중략)

Evaluation of subway-induced vibration in building using sub-structuring method (Sub-structuring 기법을 이용한 지하철 인접 구조물의 진동 예측에 관한 연구)

  • Kang, Deok-Shing;Kong, Boo-Seong;Kim, Hyo-Beom;Jeong, Min-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.635-635
    • /
    • 2014
  • 최근 지하철 인접 부지에 고층 주거 시설이 입지함에 따라 지하철 통행시의 소음 및 진동관련 민원이 증가하고 있는 추세이다. 따라서, 지하철 인접에 위치하는 구조물의 경우 계획단계에서부터 지하철로 인한 소음 및 진동 문제를 예측하고 평가하는 과정이 필수적이다. 건물이 시공되기 전 지하철 통행으로 인하여 건물에 유입되는 진동을 예측 및 평가하기 위해서는 해석적 방법으로 접근해야 하며, 본 연구에서는 sub-structuring method를 활용한 지하철 진동 해석 방법과 실제 구조물에 적용한 사례를 제시한다.

  • PDF