• 제목/요약/키워드: 고주파 효과

Search Result 414, Processing Time 0.025 seconds

Effect of Compaction Method on Induced Earth Pressure Using Dynamic Compaction Roller (진동롤러에 의한 다짐방법이 인접구조물의 다짐토압에 미치는 영향)

  • Roh, Han-Sung
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.127-136
    • /
    • 2001
  • To increase the structural integrity of concrete box culvert good compaction by the dynamic compaction roller with bi9 capacity is as effective as good backfill materials. It is needed for effective compaction that a compaction roller closes to concrete structure with high frequency. However structural distress of the culvert could be occur due to the excessive earth pressure by great dynamic compaction load. To investigate the characteristics of Induced stress by compaction, a box culvert was constructed with changing cushion materials and compaction methods. Two types of cushion material such as tire rubber chip and EPS(Expanded Polystyrene) were used as cushion panels and they are set on the culverts before backfill construction. Laboratory test result of cushion material says that the value of dynamic elastic modulus of rubber is lesser than that of EPS. On the other hand, material damping of rubber material is greater than that of EPS. In most case, dynamic compaction rollers with 10.5 ton weights were used and vibration frequency was applied 30Hz for the great compaction energy. This paper presents the main results on the characteristics of dynamic earth pressures during compaction. The amounts of induced dynamic pressures$(\Delta\sigma\;h)$ by compaction are affected with construction condition such as compaction frequency, depth of pressure cell, distance between roller and the wall of culvert and roller direction. Based on the measured values dynamic lateral pressure on the culverts, it could be said that orthogonal direction of roller to the length of culvert is more effective to compaction efficiency than parallel direction.

  • PDF

Seismic wave propagation through surface basalts - implications for coal seismic surveys (지표 현무암을 통해 전파하는 탄성파의 거동 - 석탄 탄성파탐사에 적용)

  • Sun, Weijia;Zhou, Binzhong;Hatherly, Peter;Fu, Li-Yun
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Seismic reflection surveying is one of the most widely used and effective techniques for coal seam structure delineation and risk mitigation for underground longwall mining. However, the ability of the method can be compromised by the presence of volcanic cover. This problem arises within parts of the Bowen and Sydney Basins of Australia and seismic surveying can be unsuccessful. As a consequence, such areas are less attractive for coal mining. Techniques to improve the success of seismic surveying over basalt flows are needed. In this paper, we use elastic wave-equation-based forward modelling techniques to investigate the effects and characteristics of seismic wave propagation under different settings involving changes in basalt properties, its thickness, lateral extent, relative position to the shot position and various forms of inhomogeneity. The modelling results suggests that: 1) basalts with high impedance contrasts and multiple flows generate strong multiples and weak reflectors; 2) thin basalts have less effect than thick basalts; 3) partial basalt cover has less effect than full basalt cover; 4) low frequency seismic waves (especially at large offsets) have better penetration through the basalt than high frequency waves; and 5) the deeper the coal seams are below basalts of limited extent, the less influence the basalts will have on the wave propagation. In addition to providing insights into the issues that arise when seismic surveying under basalts, these observations suggest that careful management of seismic noise and the acquisition of long-offset seismic data with low-frequency geophones have the potential to improve the seismic results.

Ototoxic Evaluation of Cis-platinum (Cis-Platinum의 이중독증에 관한 임상적 고찰)

  • 홍원표;정명현;오혜경;이경재
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.1-17
    • /
    • 1982
  • In 1965, Rosenberg reported that platinum compounds not only inhibit growth and cell division of E. coli but also has anti-tumor activity. Since then, through animal and clinical experiments by Welsch(1971), Speer(1972), Rossof(1972), Hill(1974), and Wittes(1975), it was proved that Cis-platinum has excellent supressive effects on malignant tumor, especially on head and neck cancer. Accordingly, Cis-platinum is now widely used, sometimes without any other durg, or sometimes with Bleomycin and Methotrexate etc. Inspite of the strong anticancer effect, the use of Cis-platinum is quite often discouraged because of the reports that Cis-platinum causes auditory impairment at high frequencies above the speech range due to inner ear damage and irreversible change in the renal tubules. Since Kohonen et al(1965), Standnicki et al(1974) reported that Cisplatinum has toxic effects at the basal turn of the cochlea using guinea pig, many studies on ototoxicity after infusion of Cis-platinum have been carried out using animals. But the studies on ototoxicity in human beings can hardly be found except in reports by Piel et al(1974) and Hong et al (1979). So the authors did a study which tried to clarify the ototoxic effect by comparing the hearing level after infusion of Cis-plastinum with the hearing level before infusion of Cis-plastinum in 30 patients who was treated with Cis-platinum and admitted to the dept. of otolaryngology of Yonsei University Hospital during 2 years and a half from July. 1979 to March. 1982 and the following results were obtained. 1) The results of auditory evaluation, using the pure tone average, hearing loss of 4kHz and 8kHz, Speech Reception Threshold, PB score, SISI showed that the difference of dosage does not change the hearing level after infusion of Cis-platinum and before infusion of Cis-platinum. 2) Cis-platinum had no effect on the hearing level of patients with conductive hearing loss, or with sensorineural hearing loss, as well as with normal hearing level. 3) The infusion of Cis-platinum did not cause any change in creatinine clearance, creatinine, uric acid, but only one case showed that Cis-platinum caused severe nephrotoxicity. 4) The infusion of Cis-plastinum did not cause any change in hemoglobin, leukocyte count, platelet count and there was no correlation with the amount of infusion. 5) To see the side effect of hydration practiced with the infusion of Cis-platinum, the electrolytes, particularly the K level in the serum was measured. But the results did not show any change. 6) Judging from the results of this study mentioned above, ototoxicity caused by infusion of Cis-platinum can be prevented by sufficient hydration. Also the results might say that the appropriate method of infusion of Cis-platinum might be effective in the patients with head and neck cancer who had sensorineural hearing loss for whom the infusion of Cis-platinum has been absolutely cotraindicated.

  • PDF

Psychophysiological Responses Evoked by Fear and Disgust Emotion Using Audiovisual Film Clips in Children (공포와 혐오 정서에 대한 아동의 심리생리반응)

  • Jang, Eun-Hye;Woo, Tae-Je;Lee, Young-Chang;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.10 no.2
    • /
    • pp.273-280
    • /
    • 2007
  • The study is to examine the psychophysiological responses evoked by negative emotions(fear and disgust) in children. 47 children(11-13 years old, 23 boys) participated in the study. While the children were experiencing fear or disgust emotion induced by audio-visual film clips, ECG, EDA, PPG and SKT are measured. Emotion assessment scale was used to confirm that emotions elicited by the film clips were significantly noticeable, which was measured self-report. The results turned out to be 100% and 89.4% of appropriate for fear and disgust emotions, respectively. Emotional intensity the children had experienced was rated as 4.05, 4.07 on 1-5 scale based on effectiveness of measurement of fear and disgust emotion. ANS reponses by fear and disgust were significantly between the resting state and emotional state induced. The result obtained from the fear emotion showed significant increases in SCL, NSCR, HR, RSA, RESP and HF. There was a significant difference in SCL and NSCR between the two emotions.

  • PDF

An Influence of Unit-Water Content Distribution in Ready-Mixed Concrete on Strength and Durability of Concrete (레미콘 단위수량 산포가 콘크리트 강도 및 내구성에 미치는 영향)

  • Woo, Young-Je;Lee, Han-Seung;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.375-381
    • /
    • 2008
  • Various problems such as durability degradation may happen when extra water is added to concrete. Because of these reasons, the change of water content is managed by using rapid evaluation method of unit water content such as electric capacity method, heat drying method making use of micro wave, unit capacity mass method among various methods. Especially, in Japan, guidance for the change of water content ($\pm$ 10, 15, 20 kg/$m^3$ etc.) were regulated and used. However, it is the real situation that the guidance which were regulated in South Korea evaluate suitability only considering production and measurement error under the circumstances which are not considering the degree of durability degradation. Therefore, this study tries to investigate the influence of addition of extra water in the concrete on the durability degradation of concrete when it was added by artificial manipulation or by management error. From the test results, a guideline of the contents of extra water for the quality control is suggested with the consideration of the degree of durability degradation and the probable error resulted from the addition of extra water. The contents of extra water for tests are set as 0, 15, 25, 35 kg/$m^3$. To examine the durability degradation of concrete, freezing and thawing, carbonation, chloride penetration and compressive strength are tested.

Relationship between the Level of Anxiety and ANS Responses in Children Induced by Fearful Stimulus (공포자극에 의해 유발된 자율신경계반응과 불안수준과의 관계 : 초등학생을 대상으로)

  • Jang, Eun-Hye;Lee, Young-Chang;Im, Soo-Bin;Kim, Sook-Hee;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.463-470
    • /
    • 2007
  • There have been many studies on patients who suffer from anxiety disorders. However, there is been not enough attention on the difference in the level of between the two populations with and without anxiety disorders. This study was performed to investigate the difference in the ANS responses induced by fear in children. Experimental procedures were as follow: All subjects were in upper grade levels in elementary school. ANX(anxiety) scales of PIC(Personality Inventory for Children) were used to measure fear anxiety. Audio-visual clips were used as stimulus to provoke fear emotion. Baseline of physiological signals, ECG, PPG, EDA, and SKT, were measured for 30 seconds before the fear stimulus. Physiological signals were then recorded for 2 minutes while fear is evoked. Psychological and physiological responses were analyzed. All the children reacted to the fear stimulus with high intensity of fear. Physiological responses showed that SKT, SCR, NSCR, HR, RSA, RESP, HF were increased, while R-R was significantly decreased, respectively, during the period of fear induction. Analysis of the level of anxiety and the physiological responses produced by the experience of fear revealed a statistically significant positive correlation in SKT, HR, and RSA. In other words, the higher the level of anxiety, the higher the levels of SKT, HR, and RSA when children experienced fear in conclusion, it is confirmed through this research that physiological responses to fear is associated with the level of anxiety each individual.

  • PDF

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

Acoustic Characteristics of Sound Field in Partially Opened Rooms -Emphasis on Vertical Coupling of Diffuse and Free Field- (실내공간의 부분적 개방에 따른 음향특성변화 II -확산음장과 자유음장의 수직적 결합을 중심으로-)

  • Jeong, Dae-Up;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.75-82
    • /
    • 2007
  • The present work measured and analyzed changes in the acoustics of a sound field which has a retractable ceiling. An 1/20 scale model of an openable space was built and measurement was carried out by varying the opened area of a ceiling. The most widely used room acoustic and design parameters, RT, EDT, and D50 were investigated. The results suggest that the use of RT as an acoustic design parameter may not be proper in an openable space and further it is likely to mislead the initial acoustic design of such spaces. It is mainly due to the characteristics of RT in which non-exponential decay processes are linearly fitted. Early decay times were found to be decreased in proportion to increaing the ratio of opened area. D50, an index of speech intelligibility, was effectively shows the influence of openings on the acoustics. It is also found that EDT and D50 at the seats, not directly exposed to the opened part of a ceiling, were almost linearly decreased in proportion to the ratio of opened area, while little influence was found for the opening ratio larger than 40% at the directly exposed seats to the opened part of a ceiling.

  • PDF

Unusual Angular Arrangement of Electrodes in Capacitive Heating Device -Thermal Distribution and Clinical Application- (유전 가열장치에서 전극의 각도 배열 -온도 분포의 특성 및 임상 적용-)

  • Seong, Jin-Sil;Chu, Sung-Sil;Kim, Gwi-Eon;John, Juhn-Kyu;Yang, Sung-Wha
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.313-320
    • /
    • 1989
  • In capacitive heating device, which considered efficient for deep heating, parallel arrangement of the electrodes is a serious limiting factor in heating for eccentrically located lesions because it causes overheating of the exposed ipsilateral skin surface, the heating pattern is also frequently inappropriate, and the arrangement tends to be unstable due to the patient's gravity. Therefore we attempted an angular arrangement of the electordes to achieve more homogenous and efficient heating for such lesions. In phantom study, both the thermal profile and thermogram established the heating pattern in this unusual angular arrangement of the electrodes at $60^{\circ},\;90^{\circ}\; and\;120^{\circ}$ angles, respectively. An angular arrangement was also clinically applied to 3 patients. The patients' tolerance was good without significant complication and the thermal distribution was satisfactory. In conclusion, this unusual arrangement of electrodes appears to be promising in the clinical application to the eccentrically located lesions.

  • PDF

A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System (최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.594-603
    • /
    • 2018
  • Recently, according to the development of measurement techniques, it has become possible to take complicated and time-consuming field measurements in a simple and convenient manner. In this background, this study estimated the tension of cables under ambient vibration using minimized measurement and signal processing. The VBDM using video-only by low-cost equipment was used as a minimized measurement. An estimation of the natural frequency using the mirror frequency concept was also proposed to solve the shortage of frequency band in this case. Furthermore, the FDD method was adopted for a natural frequency estimation in the ambient vibration related to field application. Experimental studies using a cable-stayed bridge model were carried out to examine the properties of the mirror frequency and the applicability of FDD with the proposed minimized system. The results showed that FDD for ambient vibration also works properly in an estimation of the natural frequency using the minimized system. In addition, the mirror frequency concept can allow a high natural frequency estimation even in a distorted signal by low-speed recording, which can overcome the limit of the minimized system. Overall, the proposed minimized system can be effective for the tension estimations of a cable under ambient vibration.