• Title/Summary/Keyword: 고주파 방사센서

Search Result 6, Processing Time 0.022 seconds

Compact Range Detection Sensor by Oscillation Frequency Deviation of an Active Antenna (능동안테나의 발진주파수 편이에 의한 소형 거리 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.528-535
    • /
    • 2011
  • In this paper, a compact doppler sensor with oscillator type active antenna operating at 2.4GHz frequency band is proposed to measure the distance to a moving object. The oscillation frequency is shifted depending on approaching of the object, and a detection circuit discriminates the frequency deviation. The active antenna has been designed and simulated. The prototype fabricated has a small circular disk type of diameter 30mm and height 4.2mm. As for antenna performance, broadside radiation pattern with beamwidth of $120^{\circ}$ and oscillation frequency of 2.35GHz has been measured. Test results as a range sensor shows that signal voltage of about 240mV has been obtained for conducting plate moving 1 meter away from the sensor. And, signal voltage has been linearly increased to the ground from 5m height by free-falling the sensor.

Performance of comparison of external-type UHF PD sensors for epoxy injection hole of barriers in GIS (GIS용 폐쇄형 스페이서의 에폭시 주입구용 UHF 부분방전 센서의 특성비교)

  • Hwang, Chul-Min;Koo, Ja-Yoon;Lee, Young-Sang;Park, Ki-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.104-106
    • /
    • 2004
  • GIS의 금속으로 차폐된 폐쇄형 스페이서(barrier)의 에폭시 주입구를 통해 방사되는 극초단파 부분방전 신호를 검출할 수 있는 외장형 UHF PD 센서를 제작하였다. 센서에 내장되는 패치안테나는 모노폴(monopole)과 다이폴(dipole) 형태로 설계하여 고주파 전자기장 해석 툴을 이용하여 각각의 특성을 계산하고 분석하였다. 제작된 센서는 362kV GIS의 차폐형 스페이서의 에폭시 주입구에 장착하고 각 센서의 PD 검출 감도와 주파수 특성을 측정하고 비교하였다.

  • PDF

Experimental Study on Temperature-Moisture Combined Measurement System for Slope Failure Monitoring (사면붕괴 모니터링에 사용되는 온도-함수비 복합계측시스템 개발에 관한 실험적 연구)

  • Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • Recently, the event of slope failure has been occurring frequently due to rapid climate changes and broad development of infrastructures, and the research for establishment of monitoring and prevention system has been an attentive issue. The major influence factors of slope failure mechanism can be considered moisture and temperature in soil, and the slope failure can be monitored and predicted through the trend of moisture-temperature change. Therefore, the combined sensing technology for the continuous measurement of moisture-temperature with different soil depths is needed for the slope monitoring system. The various independent sensors for each item (i.e. temperature and moisture respectively) have been developed, however, the research for development of combined sensing system has been hardly carried out. In this study, the high-fidelity sensor combing temperature-moisture measurement by using the minimized current consuming temperature circuit and the microwave emission moisture sensor is developed and applied on the slope failure monitoring system. The feasibility of developed monitoring system is verified by various experimental approaches such as standard performance test, mockup test and long-term field test. As a result, the developed temperature-moisture combined measurement system is verified to be measuring and monitoring the temperature and moisture in soil accurately.

Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement (인체 움직임을 고려한 소형 근접 마이크로파 심박 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.63-69
    • /
    • 2020
  • In this paper, a small microwave sensor that can be applied to a wearable device is proposed because it can detect the heartbeat signal of a human body moving irregularly at low speed. It consist of balanced microstrip radiation patches in the 2.4 GHz ISM band, self-oscillation detection circuit, and feedback circuit. Based on the theoretical development and simulation, the validity of the proposed structure was confirmed and the manufactured prototype was tested. The board size of the circuit is as small as 65mm × 85㎟, and has a low power consumption of 60mW thanks to the simple RF circuit structure. Finally heartbeat signal has been obtained from a human body moving at low speed (0.5Hz) within a linear distance of 2 to 30mm close to the sensor and a lateral distance of ±20mm.

Compact Doppler Sensor Using Oscillator Type Active Antenna (능동 발진 안테나를 이용한 소형 도플러 센서)

  • Yun, Gi-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.49-56
    • /
    • 2011
  • In this paper, a compact doppler sensor with oscillator type active antenna operating at 2.4GHz frequency band is proposed to measure the distance or speed of a moving object. The active antenna has been realized by oscillator using radiator, patch antenna, as its resonator. The oscillation frequency is shifted depending on approaching of the object, and a detection circuit discriminates the frequency deviation. The oscillator type active antenna has been designed and simulated. The prototype fabricated has a very small circular disk type of diameter 30mm and height 4.2mm. As for antenna performance, broadside radiation pattern with beamwidth of $130^{\circ}$ and oscillation frequency of 2.373GHz has been measured. Test results as a doppler sensor shows that doppler signal voltage of about 190mV has been obtained for conducting plate moving 1 meter away from the sensor. And, doppler signal voltage has been linearly increased to the ground from 4.5m height by free-falling the sensor.

New transfer standard for low vacuum region

  • 우삼용;한승웅;김부식;이상균
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.44-44
    • /
    • 1999
  • 저진공(1 kPa~ 100 kPa)은 대기압 측정, 비행고도, 기체의 온도 측정, 질량의 부력 보정, 레이저의 굴절률 측정등에 사용되는 영역으로 과학적 중요성을 갖고 있다. 또한 대기압 이상의 압력 측정과 고진공 측정의 경계적 역할도 수행하고 있어 압력 표준기의 국제 비교에 필수적으로 권장되는 역역이다. 이 영역에 주로 사용되는 압력 표준기는 수은 압력계(Mercury manometer)와 분동식 압력계(Deadweight piston gauge or Pressure)가 있다. 이들은 이동이 불편하거나 불가능하므로 표준기의 국제 비교에 사용되는 전달 표준기로는 보다 이동이 간편한 탄성 압력계인 CDG(Capacitance diaphragm Gauge)가 있다. 이 게이지는 반도체 산업의 공정 제어용으로도 많이 사용되고 있다. 그러나 게이지와 함께 사용되는 컨트롤러의 부피가 크고 무거우며 영점 이동이 커서 측정때 마다 재조정하여야 하는 단점이 있다. 본 논문에서는 이 같은 단점을 극복하기 위해 수정빔 진동형 진공 센서를 잔달 표준기로 사용하는 것에 대한 연구를 수행하였다. 수정빔 진동형 압력 센서는 수정빔으 공진주파수가 스트레인에 비례하는 것을 이용하여 제작된 센서로 주로 대기압 이상의 고압 측정에 많이 사용되고 있다. 먼저 수정빔의 압력과 주파수간의 관계를 측정하고 또한 내장된 수정 온도센서의 공진 주파수를 측정하여 온도 보상을 위한 자료로 사용하였다. 규격에 나와 있는 수정빔의 기하학적 형상으로부터 거동에 관한 이론 모델식을 구하고 압력교정 자료로부터 얻어진 데이터를 이 식과 비교 분석하여 적합한 특성식과 인자를 구하였으며 게이지의 불확도를 추정하였다.모델은 길이가 유한한 0-차원 실린더 모델로 가정하였고, 이에 대한 기하학적 성질 및 열역학적 성질은 유효계수를 고려하여 산출하였다. 진공용기 이중 벽 내부로 흐르는 질소가스의 유량과 온도의 계산은 진공용기 내벽과 외벽을 각각 독립적인 열전달 요소로 가정하여 구성한 모델을 이용하였다. 전체 해석에서 각 열전달 요소의 비열 값은 온도에 따라 변화하는 비열의 특성을 반영하였으며. 진공용기와 플라즈마 대향 부품의 방사율(emissivity)은 앞서 가정했던 각 온도 상승 곡선에 대해서 각각 0.1, 0.2, 1.3의 경우를 가정하여 계산하였다. 직선적으로 증가하는 온도 상승 곡선중 2$0^{\circ}C$/hr의 온도상승율을 갖는 경우가 다른 베이킹 시나리오 모델에 비해 효과적이라 생각되며 초대 필요 공급열량은 200kW 정도로 산출되었다. 실질적인 수치를 얻기 위해 보다 고차원 모델로의 해석이 필요하리라 생각된다. 끝으로 장기적인 관점에서 KSTAR 장치의 베이킹 계획도 살펴본다.습파라미터와 더불어, 본 연구에서 새롭게 제시된 주기분할층의 파라미터들이 모형의 학습성과를 높이기 위해 함께 고려된다. 한편, 이러한 학습과정에서 추가적으로 고려해야 할 파라미터 갯수가 증가함에 따라서, 본 모델의 학습성과가 local minimum에 빠지는 문제점이 발생될 수 있다. 즉, 웨이블릿분석과 인공신경망모형을 모두 전역적으로 최적화시켜야 하는 문제가 발생한다. 본 연구에서는 이 문제를 해결하기 위해서, 최근 local minimum의 가능성을 최소화하여 전역적인 학습성과를 높여 주는 인공지능기법으로서 유전자알고리즘기법을 본 연구이 통합모델에 반영하였다. 이에 대한 실

  • PDF