• Title/Summary/Keyword: 고조파 동조.

Search Result 28, Processing Time 0.024 seconds

A Study on the Series and Parallel Resonant Filters for Harmonic Currents Reduction of Nonlinear Loads (비선형부하의 고조파전류 저감을 위한 직렬 및 병렬 동조필터에 관한 연구)

  • 김경철;강윤모;백승현;김종욱
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.113-118
    • /
    • 2003
  • This paper characterizes typical nonlinear loads into two types of harmonic sources, i.e., harmonic voltage source and harmonic current source. A series resonant filter is very effective in harmonic reduction for harmonic voltage source type of nonlinear loads such as personal computer loads with smoothing dc capacitors. A parallel resonant filter is suited for current source type of nonlinear loads such as ac drives with smoothing dc reactors. General compensation characteristics and comparison of series and parallel resonant filters are given analytically and experimentally. Compliance with IEC Std 1000-3-2 has been evaluated for limiting harmonic distortion.

A Study on the Analysis of Harmonics Reduction Effects Using Single-tuned Filters In a Power System Included Power Converters (전력변환장치를 포함한 전력시스템에서 동조 필터를 이용한 고조파 저감 효과의 분석에 관한 연구)

  • 최홍규;김경철;강태은;전기원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.81-87
    • /
    • 2000
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system. High harmonics currents and voltages will cause equipment damage and disturb the plant operation. The common solution to harmonics problem is to use harmonics filters. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of the single-tuned filter for harmonic elimination are presented.

  • PDF

Study on tuning factor($\delta$) and quality factor(Q) for design of a single-tuned PHF (단일동조 수동고조파필터 설계시의 동조계수($\delta$) 및 양호도(Q) 값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.903_904
    • /
    • 2009
  • 본 논문에서는 대표적인 고조파 저감기법인 단일동조 수동고조파필터(single-tuned Passive Harmonic Filter)의 설계 시에 반드시 고려해야 할 최적의 동조계수($\delta$)와 양호도(Q)값의 결정 방법을 제안하였다. 두 값들은 실 사례를 통하여 결정하였고, 결정된 값들은 보드선도를 이용한 주파수 영역 해석을 수행한 후 최종적으로 이 값들을 반영하여 설계된 수동고조파필터의 성능확인을 통하여 본 논문에서 결정한 두 값들의 적합성을 평가하였다.

  • PDF

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electrolyzer Loads (전해조 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Seo, Beom-Gwan;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.12-20
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including electrolyzers. The electrolysis consists of AC-BC converters which generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides in depth an analysis on harmonics field measurement for the electrolyzer loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonic assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

A Study on the Series Resonant Filler Application and Evaluation for Personal Computer Loads (컴퓨터부하의 직렬 동조필터 적용 및 평가에 관한 연구)

  • 김경철;강윤모;이일무;송영주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.40-48
    • /
    • 2003
  • Computer loads can be found in all of modem society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as voltage waveform distortion, excessive neutral currents, errors in measurements, and disruption in computer performance. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase personal computer loads and to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEEE 519-1992 and IEC1000-3-2 standards for limiting harmonic distortion.

A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads (개인용 컴퓨터 부하의 직렬동조필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구)

  • Seo, Beom-Gwan;Kim, Kyung-Chul;Lee, Il-Moo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.36-41
    • /
    • 2006
  • Computer Loads can be found in all of modern society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as disruption in computer performance. A series resonant filter is very effective in harmonic reduction for personal computer loads. Voltage sags are short duration reductions in rms voltage. The main causes of voltage sags at faults, motor starting, and transformer energizing. Personal computers are another example of devices sensitive to voltage sags. A serious voltage sag at the terminals way lead mis-operation of the equipment. This paper presents an in depth analysis to evaluate the effect of harmonics reduction based on the IEC 61000-3-2 and the effect of voltage sag using ITI curve by applying a series resonant filter for personal computer loads.

Design of a single tuned filter for power factor improvement of UPS (무정전 전원장치의 역률개선을 위한 동조필터 설계)

  • 김수열;김장목
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.54-57
    • /
    • 1999
  • 일산복합화력발전소 소내 중요설비에 전력을 공급하는 무정전 전원장치의 출력측 전압파형의 종합 왜율을 IEEE 출력기준인 5%로 억제하여 설비의 안정적 동작을 확보하기 위하여 고조파 분석을 행하였다. 일산복합의 무정전 전원장치는 제어전원공급용으로서 부하가 콘덴서 입력형 정류기의 특성을 갖고 있으므로 3, 5, 7차의 주요 고조파를 포함하고 있다. 따라서 이들 각각에 대하여 부하측에서 본 무정전 전원장치의 임피던스를 작게 하여 전압종합왜율을 5%이하로 낮추어야 한다. 무정전전원장치의 출력전압, 전류 취득 자료를 분석하여 해당 차수의 고조파 제거와 역류개선을 위한 동조필터의 커패시터와 리액터의 용량을 결정하는 방법을 정리하였다.

  • PDF

A Study on the Measurements, Moldeling, and Passive Filter Application of Neutral Hormonic Currents by Field Tests (현장시험에 의한 중성선 고조파 전류 측정, 모델링 및 수동필터 적용에 관한 연구)

  • 김경철;강윤모;이일무
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 2003
  • With the proliferation of nonlinear loads such as personal computer in an educational building, high neutral harmonic currents have been observed. High neutral currents in three-phase four ire distribution power systems can cause tots of harmonic problems such as overloaded neutral conductors and malfunction of protective equipment. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuits was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the effect of a single-tuned passive filter for the neutral harmonic current reduction are presented.

Harmonics Compensation by Using an Impedance Source Hybrid Active Power Filter (임피던스 소스 네트워크를 갖는 복합형 능동필터에 의한 고조파 보상)

  • Kim, Jae-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.154-156
    • /
    • 2008
  • 본 연구에서는 종전의 전압형 및 전류형 능동전력필터를 대체 할 수 있으며, 부하의 특성에 무관하게 적용 가능한 Z-소스 인버터(Z-source inverter) 토폴로지의 능동전력필터에 대하여 고찰하였다. Z-소스 토폴로지의 능동전력필터의 보상 직류전원으로는 연료전지 PEMFC를 사용하였다. 본 연구에서 제안된 시스템은 고조파 발생원 비선형 부하와 병렬로 연결된 Z-소스 능동전력필터와 7고조파 (420Hz) 동조 필터로 구성되며 Z-소스 능동전력필터의 스위치 스트레스를 감소할 수 있다. 제안된 Z-소스 하이브리드 능동전력필터(Z-HAF : Z-source hybrid active power filter)의 보상 알고리즘으로는 전류 동기 검출법(CSD)을 사용하였으며, PSIM 시뮬레이션에 의하여 제안된 Z-HAF의 정상상태에서의 보상 성능을 파악하였다.

  • PDF