• Title/Summary/Keyword: 고정사업장

Search Result 14, Processing Time 0.02 seconds

Design and Implementation of Turbidity Measurement Module of Plume using a Digital Camera (디지털카메라를 이용한 굴뚝연기의 혼탁도 측정모듈의 설계 및 구현)

  • Ban, ChaeHoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.372-378
    • /
    • 2015
  • Smoke generated from business establishments and factories will not only cause air pollution but also have a significant impact on the human body. Generally, the most common method for measuring the turbidity of the plume generated from the stack is a method of observing by the transmissometer mounted in the chimney or Method 9 from the US EPA(Environmental Protection Agency) which is a visual method of determining plume turbid emitted from stationary sources. However, these methods need a lot of cost to build and maintain. In this paper, we build a plume turbidity measurement module programs using a digital camera. We design and implement a module which acquires the pictures of the plume using a digital camera and measures the turbidity of it using the DOM(Digital Optical Method). In addition, we demonstrate the excellence by comparing and analyzing implemented module and other methods.

Design and Implementation of Turbidity Measurement Module of Plume using Optical Sensing (광학센싱을 이용한 굴뚝연기의 혼탁도 측정모듈의 설계 및 구현)

  • Ban, ChaeHoon;Son, HyunGeun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.312-315
    • /
    • 2014
  • Smoke generated from business establishments and factories will not only cause air pollution but also have a significant impact on the human body. Generally, the most common method for measuring the turbidity of the plume generated from the stack is a method of observing by the transmissometer mounted in the chimney or Method 9 from the US EPA(Environmental Protection Agency) which is a visual method of determining plume turbid emitted from stationary sources. However, these methods need a lot of cost to build and maintain. In this paper, we build a plume turbidity measurement module programs using light sensing. We design and implement a module which acquires the pictures of the plume using a digital camera and measures the turbidity of it using the DOM(Digital Optical Method). In addition, we demonstrate the excellence by comparing and analyzing implemented module and other methods.

  • PDF

A Study on Measurements of Autoignition and Activation Energy of Superabsorbent Polymers (고흡수성 중합체의 자연발화와 활성화에너지 측정에 관한 연구)

  • Jong-Man Heo;Jae-Wook Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.292-304
    • /
    • 2023
  • Purpose: This study was conducted to obtain experimental data for the establishment of preventive measures against fire, as large and small fire accidents occur at production and storage sites of superabsorbent polymers developed for the convenience of daily life. Method: The sample container was fixed at 0.2m in both length and width, and was shaped into a rectangular cuboid with heights of 3cm, 5cm, 7cm, and 14cm to access an infinite flat plane. The sample container was fixed in the center of a thermostatic bath that was heated to a predetermined temperature according to a preset temperature control program. If the central temperature of the sample rose more than 20℃ above the set temperature, it was determined to have 'ignited', and if it remained similar to the set temperature, it was determined to have 'unignited'. Result: The critical autoignition temperature was calculated to be 212.5℃ for a sample container with a height of 3cm, 202.5℃ for 5cm, 192.5℃ for 7cm, and 177.5℃ for 14cm. The ignition induction time to reach the highest temperature was approximately 42hours for 3cm, 91hours for 5cm, 151hours for 7cm, and 300hours for 14cm. Conclusion:① As the size of the sample container increased, the autoignition temperature decreased and the ignition induction time to reach the highest temperature increased. ② The apparent activation energy was calculated to be 39.30kcal/mol, with a correlation of 99.5%.

Mobile Sensor Velocity Optimization for Chemical Detection and Response in Chemical Plant Fence Monitoring (사업장의 경계면에서 화학물질 감지 및 대응을 위한 이동식 센서 배치 최적화)

  • Park, Myeongnam;Kim, Hyunseung;Cho, Jaehoon;Lulu, Addis;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.41-49
    • /
    • 2017
  • Recently, as the number of facilities using chemicals is increasing, the amount of handling is rapidly increasing. However, chemical spills are occurring steadily, and if large quantities of chemicals are leaked in time, they are likely to cause major damage. These industrial complexes use information obtained from a number of sensors to detect and monitor leaking areas, and are used in industrial fields by applying existing fixed sensors to robots and drones. Therefore, it is necessary to propose a sensor placement method at the interface for rapid detection and response based on various leaking scenarios reflecting leaking conditions and environmental conditions of the chemical handling process. In this study, COMSOL was used to analyze the actual accident scenarios by applying the medium parameter to the case of chemical leaks. Based on the accident scenarios, the objective function is selected so that the velocity of each robot is calculated by attaching importance to each item of sensor detection probability, sensing time and sensing scenario number. We also confirmed the feasibility of this method of reliability analysis for unexpected leak accidents. Based on the above results, it is expected that it will be helpful to trace back the leakage source based on the concentration data of the portable sensor to be applied later.