• Title/Summary/Keyword: 고전기장

Search Result 13, Processing Time 0.023 seconds

Development of FBG Accelerometer for Railway Tunnel Vibration (철도터널 진동 모니터링을 위한 광섬유 가속도계 개발)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki;Lee, Kyu-Wan
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.364-369
    • /
    • 2011
  • For the safety management of tunnel, effective measurements should be continuously carried out. Most of sensors currently being applied for tunnels measure only the local status, thus many of them are needed to monitor an entire tunnel. For the railway tunnel where trains of same conditions are regularly operated, dynamic responses of tunnel structure to train operations can be a good index to estimate the deformation of tunnel structure in wide area. Meanwhile, the electromagnetic interference caused by overhead centenary in railway tunnel obstructs the use of electric-based sensors. In this study a brand new accelerometer using FBG optical fiber sensors is developed to solve these problems. Sensitivity and capacity of the accelerometer are enhanced with effective structural design of its components and verified with laboratory tests. A case history where the developed accelerometers were applied to a safety monitoring system of a high-speed train tunnel is presented. The performances of the developed accelerometers are validated from the measured acceleration data.

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

Quality Changes and Pasteurization Effects of Citrus Fruit Juice by High Voltage Pulsed Electric Fields (PEF) treatment (고전압 펄스 전기장 처리에 의한 감귤주스의 품질변화)

  • Kim, Kyung-Tack;Kim, Sung-Soo;Hong, Hee-Do;Ha, Sang-Do;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.635-641
    • /
    • 2003
  • A non-thermal pasteurization technology, high Pulsed Electric Field (PEF) has been thought to be a new alternative processing technology instead of heating. The objective of this study was to examine and compare the effect of PEF and High Temperature Short Time (HTST) treatments on the physicochemical, microbiological and sensory characteristics of citrus juices. Total sugar and titratable acidity values of fresh citrus juice and two treatments were not significantly different each other at p<0.05. The concentration of vitamin C in fresh citrus juice $(31.2{\pm}0.59\;mg%)$ was not significantly different with the value of PEF treatment $(29.4{\pm}0.75\;mg%)$ but was significantly higher than the value of HTST treatment $(27.4{\pm}0.75\;mg%)$. The color values (L, a, and b) in PEF treatment were significantly lower than the fresh citrus juice, but were higher than the values of HTST treatment. Both total bacterial cell counts $(6.65\;{\pm}\;0.08\;log_{10}(cfu/mL))$ and yeast counts $(7.79{\pm}0.07\;log_{10}(cfu/mL))$ in fresh citrus juice were significantly reduced by PEF $(1.39{\pm}0.14,\;2.42{\pm}0.1\;log_{10}(cfu/mL))$ as well as HTST treatment (0, 0). PE activity of fresh citrus juice $(1.3{\pm}0.12\;units/mL)$ was significantly reduced by PEF treatment $(0.11{\pm}0.01\;units/mL)$ and was totally inactivated by HTST treatment. Sensory evaluation scores in flavor, taste and overall acceptability between the fresh and PEF treated citrus juices $(7.2{\sim}7.5)$ were not significantly different but the values of HTST treatment $(5.1{\sim}5.8)$ were lower than others. Consequently, PEF treatment is thought to be a good alternative pasteurization method for fresh citrus juice to HTST treatment due to its strong pasteurization effect, reduced destruction of nutrients and good sensory characteristics.