• Title/Summary/Keyword: 고장감시

Search Result 254, Processing Time 0.028 seconds

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.

A Study on the Stress Corrosion Cracking Propagation Behaviors of high Strength Steel by Means of Emission Test (음향방출시험에 의한 고장력강의 응력부식 균열전파 거동에 관한 연구)

  • Yu, Hyo-Seon;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.361-371
    • /
    • 1993
  • Among the various test methods for stress corrusiun cracking(SCC) susceptibility evaluatiun, the slow stram rate test(SSHT) method is a rapid and effective nwthod to evaluate the SCC susceptibility of metal in relatively short time. But it is very difficult to analyze the microfracture behaviors in SCC process by using the test(SSRT) method only. Up to now, it has been well known that the acoustic emission(AE) test is the effective technique to monitor the microcrack initiation and propagation in material fracture pmcess. Therefore. in this paper, we analyzed the correlation between the see process and the characteristics of AE signal by using the SSHT and the AE test. According to the test results. the AE signals produced from the material microfracture were clearly depended on the test environment. The AE signal characteristics generated during see process in synthetic sea water were comparatively greater than those. in air. In addition, the SCC behaviors could be definitely evaluated by the amplitude parameter of AE signals.

  • PDF

Design and Implementation of KPX's next control center (전력거래소 차기 계통운영시스템 설계에 관한 연구)

  • Choi, Young-Min;Park, Min-Ryung;Lee, Jin-Su;Lee, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.380-381
    • /
    • 2011
  • 전력거래소는 2014년 나주본사이전 이후 1억kW 대용량 전력계통을 운영하기 위한 차기 계통운영시스템(이하 차기EMS) 구축을 계획하고 있다. EMS(Energy Management System)는 전국의 발, 변전소에서 계통정보를 실시간으로 취득하여 전력계통을 감시하며, 연료비 기반의 최적 경제점을 찾아 발전기를 제어하고, 전력계통을 수식화한 상태추정 결과를 기반으로 상정사고분석, 고장전류계산 등 전력계통운영을 위한 종합시스템이다. 국내 EMS의 역사는 1979년 미국의 L&N 시스템 도입을 시작으로 1988년 일본의 Toshiba EMS, 2001년 Alstom사의 NEMS를 구축하여 현재 운영중에 있다. 하지만, 외산 제품 도입에 따른 기술이전, 유지보수의 어려움을 타개하기 위해 2004년 한국형 EMS(이하 K-EMS) 연구개발계획을 수립하고 전력거래소를 주축으로 한 산학연을 구성하여 2010년 K-EMS 개발을 성공적으로 완료하였다. 차기 EMS는 국내 기술력으로 개발된 정부연구과제 성과물인 K-EMS를 기반으로 구축이 이루어지며, 총 3년간의 개발 및 시험과정을 거쳐 실계통운영을 담당할 예정이다. 차기EMS가 설치되어 운영예정인 급전소는 전력수급 균형유지와 발전소 운영 총괄 지휘 및 765kV, 345kV 송전망 운영역할을 담당할 나주급전소와 154kV 비수도권 송전망 운영을 담당할 천안급전소, 154kV 수도권 송전망 운영을 책임질 서울급전소 이상 3곳이다. 차기EMS는 발전 및 송, 변전 설비의 대형화, 다양한 FACTS 설비, 신재생에너지원으로 대표되는 분산전원의 등장과 같은 급변하는 전력계통 변화에 능동적인 역할을 성공적으로 수행할 것으로 기대하고 있다.

  • PDF

Application for en-Route mission to Decentralized Task Allocation (경로가 주어진 임무 상황에서 분산 임무할당 알고리즘의 적용 방안 연구)

  • Kim, Sung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.156-161
    • /
    • 2020
  • In an environment that operates multiple UAVs, the use of a decentralized task allocation algorithm has more robustness from a single failure of UAV on the mission because there is no central command center. In addition, UAVs have situational awareness and redistribute tasks among themselves, which can expand the mission range. The use of multiple UAVs in a mission has increased as the agent hardware has decreased in size and cost. The decentralized mission-planning algorithm has the advantages of a larger mission range and robustness to a single failure during the mission. This paper extended the type of mission the uses CBBA, which is the most well-known decentralized task allocation algorithm, to the point mission and en-route mission. This will describe the real mission situation that has the purpose of surveillance. A Monte-Carlo simulation was conducted in the case of multiple agents in the task-rich environment, and the global rewards of each case were compared.

A Development of Cipher Device based on Embedded Linux for Serial Communication in SCADA (임베디드 리눅스 기반의 SCADA 직렬통신 구간 암호화 장치 개발)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.25-32
    • /
    • 2010
  • The Supervisory Control and Data Acquisition Systems (SCADA) system provides monitoring, data gathering, analysis, and control of the equipment used to manage most infrastructure. The SCADA Network is implemented in a various manner for larger utilities, and multiple types of protocol and communication interfaces are used to network the control center to remote sites. The existing SCADA equipment and protocols were designed and implemented with availability and efficiency, and as a result security was not a consideration. So, performance, reliability, flexibility and safety of SCADA systems are robust, while the security of these systems is often weak. This makes some SCADA networks potentially vulnerable to disruption of service, process redirection, or manipulation of operational data that could result in public safety concerns and/or serious disruptions to the infrastructure. To reduce the risks, therefore, there is a need to have a security device such as cipher devices or cryptographic modules for security solutions. In this paper we develop an embedded cipher device for the SCADA equipment. This paper presents a cipher device designed to improve the security of its networks, especially in the serial communication.

Implementation of Incoming Panel Monitoring System using Open Source Platform and Wi-Fi Networks (오픈소스 플랫폼 및 Wi-Fi를 이용한 수배전반 모니터링 시스템 구현)

  • Kang, Jin-Young;Kang, Hag-Seong;Jeong, Sung-Hak;Park, Mi-Young;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.886-887
    • /
    • 2015
  • There is a growing interest in and demand for power industry acceleration and energy efficiency due to the increased energy consumption, environmental issues. Electronic power IT convergence industries such as intelligent power system has attract attention as new growth engine industry. A large number of sensors and motors are being installed following unmanned, automated in existing incoming panel management system. Observe the operating conditions and rapid response is essential. Despite the need for immediate action to be taken in the event of various later failed to recognize the emergency power can lead to accidents. In this paper, we propose a new architecture of the implementation of incoming panel monitoring system for power monitoring, fault detection, maintenance and system control using open source hardware platform and Wi-Fi networks.

  • PDF

A Design of Power Management and Control System using Digital Protective Relay for Motor Protection, Fault Diagnosis and Control (모터 보호, 고장진단 및 제어를 위한 디지털 보호계전기 활용 전력감시제어 시스템 설계)

  • Lee, Sung-Hwan;Ahn, Ihn-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.516-523
    • /
    • 2000
  • In this paper, intelligent methods using digital protective relay in power supervisory control system is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which has various load environments and capacities in power systems. The spectrum pattern of input currents was used to monitor to state of induction motors, and by clustering the spectrum pattern of input currents, the newly occurrence of spectrums pattern caused by faults were detected. For diagnosis of the fault detected, the fuzzy fault tree was derived, and the fuzzy relation equation representing the relation between an induction motor fault and each fault type, was solved. The solution of the fuzzy relation equation shows the possibility of each fault's occurring. The results obtained are summarized as follows: 1) The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protective relay is improved within ${\pm}5%$. 2) Using clustering algorithm by unsupervisory learning, an on-line fault detection method, not affected by the characteristics of loads and rates, was implemented, and the degree of dependency by experts during fault detection was reduced. 3) With the fuzzy fault tree, fault diagnosis process became systematic and expandable to the whole system, and the diagnosis for sub-systems can be made as an object-oriented module.

  • PDF

Design of Measuring System for Insulation Resistance and Humidity in High-Power XLPE Cables in Operation and the Relationship Between Insulation Resistance and Humidity in the Oversheath (운전 중인 고전력 XLPE 케이블의 절연저항과 습도의 측정 시스템 설계 및 방식층 절연저항과 습도의 상관관계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.179-184
    • /
    • 2016
  • The usual way used by electric power stations to deliver high levels of generated power is via 6.6kV XLPE (or CV) cables. Depending on the manufacturing technique, installation environment, and usage conditions, the deterioration processes of the power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to the manufacturing or construction defects. Otherwise they should be in good working order for 20-30 years. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to the dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables at Korean Western Power Co. Ltd. located in Taean, Chungcheongnam-do province. In this paper, we introduce the device hardware. Using the device, we have measured the insulation resistance and humidity in the sheath of the cables. We present, in analysed results, the effect of humidity on insulation resistance in cable sheaths.

Design of Emergency Evacuation Guiding System with Serially Connected Multi-channel Speakers (직렬 스피커 연결을 이용한 비상 대피 유도 시스템의 설계)

  • Chung, Han-Vit;Kim, Tea-Wan;Chung, Yun-Mo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.4
    • /
    • pp.142-152
    • /
    • 2011
  • In general, existing emergency evacuation guiding systems depend on visual techniques like emergency lights or LEDs. Actually people in the case of fire emergency condition may not obtain a range of view because of smoke from the fire. This paper introduces a technique to design an emergency guiding system using directivity sound to cope with this problem. In this case all speakers are serially connected for audio signal transmission in a serial fashion to achieve convenient speaker installation. Floyd algorithm is used to find shortest evacuation paths. Because serially connected multi-channel speakers are weak in case of disconnection, this paper uses a technique to solve the diagnostic problem. In the proposed system, a PC based on the USB protocol is used for control and observation. The system has achievements, such as increasing evacuation rate under emergency conditions, and serial transmission of audio signal for easy maintenance and low installation cost.