• Title/Summary/Keyword: 고온구조강도시험

Search Result 82, Processing Time 0.035 seconds

Influence of Thermal Aging on the Properties of Polyurethane Coating of Waterproof. (우레탄 도막 방수재의 열열화 특성)

  • Kim, Sung-Rae;Shin, Hong-Chol;Shin, Ju-Jae;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.931-934
    • /
    • 2008
  • Polyurethane apply to the waterproof widely. Polyurethane rubbers are prepared that the influences of a thermal aging on the properties are investigated. Polyol and Polyisocyanate were varied ratio in the range mixed by using individual product that was vulcanized by a hot. The waterproofs of Polyurethane were investigated about tensile strength, tear strength and elongation after the thermal Aging for 168, 336, 504 hrs at 70$^{\circ}$C and 80$^{\circ}$C in the air oven. As the increase of the thermal aging time, tensile strength, tear strength and elongation were reduced.

  • PDF

CVD에 의한 흑연페블의 SiC 코팅기술 개발

  • Yu, In-Geun;Park, Lee-Hyeon;An, Mu-Yeong;Gu, Deok-Yeong;Jo, Seung-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.231-231
    • /
    • 2012
  • 7개 나라가 참여해서 공동으로 제작하고 있는 국제핵융합실험로(ITER)는 2020년경에 제작 설치가 완료될 예정이다. ITER 장치에는 6개의 시험 블랑켓 모듈(Test Blanket Module : TBM)이 장착될 예정이며, 그 중에서 한국도 1개를 독자적으로 제작해서 설치할 예정이다. 한국형 헬륨 냉각 고체형 증식(Helium Cooled Solid Breeder : HCSB) TBM이며, 한국은 ITER 참여국 중 유일하게 중성자 반사 재료를 채택한 것이 특징이다. 중성자 반사재료로는 지름 1 mm 내외의 흑연 페블에 SiC를 코팅해서 사용할 예정이다. SiC는 고온저방사화 물질로 차세대 핵융합로의 구조 재료로도 개발되고 있는 물질로, 이렇게 하면 흑연의 단점인 기계적 특성 향상뿐만 아니라, 산화나 화재 등에 대한 사고의 부담도 크게 줄일 수 있는 장점이 있다. 흑연위에 SiC를 코팅하는 방법은 여러 가지가 있으며, 그 중에서 비교적 간단한 건식 방법은 RF Sputtering, PECVD 등이 있다. 건식은 코팅방법이 간단하고 비교적 쉬운 편이지만 페블표면에 양질의 SiC 박막을 얻기가 쉽지 않은 단점이 있다. 이들 방법보다 습식법은 코팅이 까다롭지만 양질의 코팅막을 비교적 쉽게 얻을 수 있는 장점이 있다. CVD의 경우 전구체 물질로 여러 가지 물질이 사용될 수 있으며 대표적으로 $SiH_4$, $Si(CH_3)_4$, $CH_3SiCl_3$ 등이 있으며, 캐리어 가스로는 $H_2$가 사용된다. 이렇게 얻어진 SiC 코팅페블은 흑연에 비해 파괴강도도 향상되고 마모 등에 강한 것을 확인할 수 있었다.

  • PDF

An experimental study on the liquid rocket engine combustion gas cooling (액체로켓 엔진 연소가스 냉각에 관한 실험적 연구)

  • 김현중;유석진;임하영;우유철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.266-269
    • /
    • 2003
  • During liquid rocket engine combustion, the resulting combustion gas has flow characteristics of high temperature and high velocity. An experimental study was performed to obtain basic data for a flame deflector design that is endurable under such flow characteristics. While the injected-water cools down the combustion plume, temperature and pressure of the plume was measured. As the experiment is being performed, gas temperature was measured using infrared cameras, and the gas temperature data was compared with the temperature data from the sensor in the plume. With the results of this experiment, we were able to obtain applicable temperature data for flame deflector design and predict the performance and structural strength required for installation of water injector.

  • PDF

Molecular Structure and Tensile Properties Change of Crosslinked Polyethylene Pipes during Oxidative Degradation Process (산화열화과정 중 가교폴리에틸렌 파이프의 분자구조 및 인장 특성 변화)

  • Park, Sung-Gyu;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.520-524
    • /
    • 2009
  • The effects of oxidative degradation on the performance of crosslinked polyethylene pipes were analyzed by the investigation of tensile properties and chemical structure change of the pipes during oxidative degradation. Annealing at high temperatures or UV irradiation method was used to induce the oxidative degradation of the crosslinked polyethylene pipes and the effects of the die temperature on the oxidative degradation of the pipes were also investigated. The tensile properties and chemical structure change of the pipes were investigated by universal testing machine and FT-IR, respectively. With the progress of thermo-oxidative degradation the tensile strength of the pipes slowly decreased but the elongation at break rapidly decreased, and the chemical structure of the pipes also changed considerably because of the introduced oxygen molecules. These results would be useful in estimating the performance deterioration of the crosslinked polyethylene pipes due to the oxidative degradation during production and storage.

Assessment of Fire-Damaged Mortar using Color image Analysis (색도 이미지 분석을 이용한 화재 피해 모르타르의 손상 평가)

  • Park, Kwang-Min;Lee, Byung-Do;Yoo, Sung-Hun;Ham, Nam-Hyuk;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.83-91
    • /
    • 2019
  • The purpose of this study is to assess a fire-damaged concrete structure using a digital camera and image processing software. To simulate it, mortar and paste samples of W/C=0.5(general strength) and 0.3(high strength) were put into an electric furnace and simulated from $100^{\circ}C$ to $1000^{\circ}C$. Here, the paste was processed into a powder to measure CIELAB chromaticity, and the samples were taken with a digital camera. The RGB chromaticity was measured by color intensity analyzer software. As a result, the residual compressive strength of W/C=0.5 and 0.3 was 87.2 % and 86.7 % at the heating temperature of $400^{\circ}C$. However there was a sudden decrease in strength at the temperature above $500^{\circ}C$, while the residual compressive strength of W/C=0.5 and 0.3 was 55.2 % and 51.9 % of residual strength. At the temperature $700^{\circ}C$ or higher, W/C=0.5 and W/C=0.3 show 26.3% and 27.8% of residual strength, so that the durability of the structure could not be secured. The results of $L^*a^*b$ color analysis show that $b^*$ increases rapidly after $700^{\circ}C$. It is analyzed that the intensity of yellow becomes strong after $700^{\circ}C$. Further, the RGB analysis found that the histogram kurtosis and frequency of Red and Green increases after $700^{\circ}C$. It is analyzed that number of Red and Green pixels are increased. Therefore, it is deemed possible to estimate the degree of damage by checking the change in yellow($b^*$ or R+G) when analyzing the chromaticity of the fire-damaged concrete structures.

Investigation of Properties of Structural Foam with Different Conformation and via Thermal Aging Condition (구조용 폼의 조성 및 열 노화에 따른 변형특성 관찰)

  • Choe, Jin-Yeong;Kwon, Il-Jun;Park, Sung-Min;Kwon, Dong-Jun
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.122-127
    • /
    • 2018
  • Sandwich composites of carbon fiber reinforced plastic(CFRP) and polymer foam will be used to automobile and aerospace industry according to increasing importance of light weight. In this study, mechanical and heat resistance properties of sandwich composites were compared with type of polymer foam (polyethylene terephthalate(PET), polyvinylchloride(PVC), epoxy and polyurethane). All types of polymer foams were degraded to 30, 60, 120, 180 minutes in $180^{\circ}C$. After heat degradation, the polymer foams were observed using optical microscope and compressive test was performed using universal testing machine(UTM). Epoxy foam had the highest compressive property to 2.6 MPa and after thermal degradation, the mechanical property and structure of foam were less changed than others. Epoxy foam had better mechanical properties than other polymer foams under high temperature. Because the epoxy foam was post cured under high temperature. As the results, Epoxy foam was optimal materials to apply to structures that thermal energy was loaded constantly.

Experimental Study on the Fire Performance of PC Slab by the Bearing Length (걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구)

  • Park, Siyoung;Kang, Thomas H.K.;Lee, Ho-Wook;Gwak, Si-Young;Park, Jun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.14-22
    • /
    • 2022
  • In this study, a fire test was conducted to evaluate the fire performance of precast concrete (PC) slabs in an outdoor environment in response to the increase in fire incidents caused by the growth of warehouses. Prior to the field fire test, the tensile yield strength of the tendon at elevated temperatures was tested to analyze the mechanical properties. Also, by referring to previous studies, the thermal properties of tendon and the mechanical and thermal properties of concrete were investigated. A field fire test was conducted to analyze the structural and fire performance of two identical slabs with 50 and 150 mm bearing length. As the bearing length increased, deflection and horizontal displacement decreased. The fire test lasted for 200 minutes without the collapse of slabs, validating current codes. Based on the structural performance which maintained even with concrete spalling and rupture of some tendons, the bonded method is assumed to be practical in pre-tensioned PC slabs. The results of fire test are expected to be utilized in evaluating the fire performance of PC slabs in warehouses.

Development of 2-ton thrust-level sub-scale calorimeter (추력 2톤급 축소형 칼로리미터 개발)

  • Cho, Won-Kook;Ryu, Chul-Sung;Chung, Yong-Hyun;Lee, Kwang-Jin;Kim, Seung-Han;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2005
  • A calorimeter of 2-ton thrust level rocket engine chamber has been developed to measure the wall heat flux. The liner of the chamber is made of copper-chromium alloy to maximize the heat transfer performance and structural strength. 1-D design code based on empirical correlations has been used for the prediction of the global thermal characteristics while 3-D CFD has been applied for the verification of local cooling performance. The predicted average wall heat flux at the throat is 43 $MW/m^{2}$ for the combustion chamber pressure of 53 bar. The chamber structure is confirmed to be safe at the pressure of 150 bar through 2-D stress analysis and measurement of the strain of the test species. Finally, the test of pressurizing the calorimeter chamber has been performed with water at the pressure of 150 bar in room temperature environment. No thermal damage has been detected after the hot-fire test in the test nozzle of same cooling performance with the developed calorimeter though the measured throat heat flux is higher than the design value by 10%.

Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior (CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가)

  • Choi, Ji-Su;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.174-179
    • /
    • 2021
  • Currently, fluid transfer steel pipes take a lot of time and expense to maintain all facilities due to new construction and painting or corrosion and aging. Therefore, this study was conducted for designing a CFRP pipe structure with high corrosion resistance and chemical resistance as a substitute for steel pipes. The helical/hoop pattern was cross-laminated to improve durability, and HNT was added to suppress the moisture absorption phenomenon of the epoxy. The HNT/CFRP pipe was manufactured by a filament winding process, and performed a mechanical property test, and a moisture absorption test in distilled water at 70℃. As a result, the highest bending strength was obtained when the hoop pattern was laminated with a thickness equivalent to 0.6% of the pipe. The 0.5 wt% HNT specimen had the highest moisture absorption resistance. Also, the delamination phenomenon at the interlayer interface was delayed, resulting in the lowest strength reduction rate.

Study on the physical properties of nylon66/glass fiber composites as a function of extrusion number (나일론66/유리섬유 복합체의 압출횟수에 따른 특성 연구)

  • Lee, Bom Yi;Kim, Youn Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3990-3996
    • /
    • 2014
  • Because the physical properties can be decreased when a Nylon 66/glass fiber composite is injected into a mold over $300^{\circ}C$, a systematic study of the thermal history in the case of re-use is needed. Nylon 66/glass fiber extrudates as a function of the extrusion number were prepared using a twin screw extruder at 305/290/273/268/265/$260^{\circ}C$. The chemical structure, thermal properties, melt index, crystal structure, Izod impact strength, and rheological properties were measured by Fourier transform infra-red (FT-IR), melt indexer, DSC, TGA, XRD, Izod impact tester, and dynamic rheometer. The FT-IR spectra indicated that the number of extrusions did not affect the chemical structure. The decrease in molecular weight with increasing extrusion number was confirmed by the melt index and the complex viscosity of extrudates. Based on the DSC and TGA results, the thermal history had no effect on the melting temperature, regardless of the number of extrusions, but the degradation temperature decreased up to $20^{\circ}C$ with increasing extrusion number. The Izod impact strengths of the extrudates were found to decrease with increasing extrusion number. No structural change after extrusion was also confirmed because there was no change in the slope and shape of the G'-G" plot.