Search Result 318, Processing Time 0.021 seconds

Evaluation of Flexural Ductility of Negative Moment Region of I-Girder with High Strength Steel (고강도 강재 적용 I-거더의 부모멘트부 휨연성 평가)

  • Joo, Hyunsung;Moon, Jiho;Choi, Byung-Ho;Lee, Hak-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.513-523
    • /
    • 2010
  • For continuous I-girder bridges, a large negative bending moment is generated near pier region so that plastic hinge is first formed at this point. Then, the bending moment is redistributed when the I-girder has enough flexural ductility (or rotational capacity). However, for I-girder with high strength steel, it is known that the flexural ductility is considerably decreased by increasing the yield strength of material. Thus, it is necessary to conduct a study for guaranteeing proper flexural ductility of I-girder with high-strength steel. In this study, the evaluation of flexural ductility of negative moment region of I-girder with high strength steel where yield stress of steel is 680 MPa is presented based on the results of finite element analysis and experiment. From the results, it is found that the flexural ductility of the I-girder is significantly reduced due to the increase of elastic deformation and the decrease of plastic deformation ability of the material when the yield strength increases. In this study, the method to improve the flexural ductility of I-girder with high strength steel is proposed by an unequal installation of cross beam and an optimal position of cross beam is also suggested. Finally, the effects of the unequal installation of cross beam on the flexural ductility are discussed based on the experimental results.

Confinement Effects of High Strength Reinforced Concrete Tied Columns (고강도 철근콘크리트 띠철근 기둥의 구속효과)

  • 신성우;한범석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.578-588
    • /
    • 2002
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$1200 mm) were tested. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were considered. High-strength concrete columns under concentric axial loads show extremely brittle behavior unless the columns are confined with transverse reinforcement that can provide sufficiently high lateral confinement pressure There is a consistent decrease in deformability of column specimen with increasing concrete strength. Test results were compared with the previous confinement model such as modified Kent-Park, Sheikh-Uzumeri, Mander, and Saatcioglu-Razvi model. The comparison indicates that many previous models for confined concrete overestimate or underestimate the ductility of confined concrete.

Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers (고연성 PET 섬유로 보강된 철근콘크리트 원형 기둥의 내진성능)

  • Vachirapanyakun, Sorrasak;Lim, Myung-Kwan;Choi, Dong-Uk
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.289-298
    • /
    • 2016
  • An experimental research was performed using fibers for the purpose of retrofitting existing reinforced concrete circular columns. Glass fiber (GF) and polyethylene terephthalate (PET) were used as well as combined GF+PET (HF). PET has high tensile strength (over 600 MPa) and high ductility (about 15%), but has very low elastic modulus (about 1/6 of GF). A total of four columns was tested against laterally applied reverse cyclic load: control column, GF-, PET-, and HF-strengthened columns. All columns retrofitted using fibers demonstrated improved moment capacity and ductility. Moment capacity of GF-, PET-, and HF-strengthened columns was 120%, 107%, and 120% of the control column, respectively. Drift ratio of all retrofitted columns also increased by 63 ~ 83% over the control column. The final failure mode of the control column was main bar buckling. The final failure mode of the GF- and HF-strengthened columns was GF rupture while that of the PET-strengthened column was main bar rupture in tension. No damage was observed for PET at the ultimate stage due to excellent strain capacity intrinsic to PET. Current test results indicate that PET can be effectively used for seismic retrofit of RC columns. It is noted that the durability characteristics of PET needs to be investigated in the future.

A Study on Moment Redistribution Effect of Continuous I-girder (재분배 모멘트를 고려한 I-거더 연속교의 휨거동에 관한 연구)

  • Joo, Hyunsung;Park, Donghyun;Choi, Byung-Ho;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.36-36
    • /
    • 2011
  • I-거더 형식의 연속교 교각 부근에서는 큰 부모멘트가 작용하게 되며 이로 인하여 소성힌지가 생성되게 된다. 소성힌지가 형성됨에 따라 교각 부근의 부모멘트는 감소하게 되며, 정모멘트부의 휨모멘트는 반대로 증가하게 된다. 이러한 모멘트 재분배가 원활히 발생하기 위해서는 소성힌지가 충분한 휨연성 혹은 단면회전 능력을 가지고 있어야 한다. 하지만 고강도 강재를 적용한 연속교에서는 재료연성이 다소 떨어지는 경향이 있고, 재료의 항복응력이 증가할수록 I-거더의 탄성 변형량은 이에 비례하여 증가하므로, 소성변형 능력 및 휨연성이 감소하는 것으로 알려져 있다. 따라서, 고강도 강재를 I-거더 형식의 연속교에 적용할 때 부모멘트부의 휨연성을 정량적으로 예측하여 재분배 모멘트가 원활히 이루어 지는지에 대한 연구가 필요하다. 본 연구에서는 유한요소해석 연구를 통하여 고강도강재 적용 I-거더 연속교의 재분배 모멘트를 고려한 휨거동 대하여 연구를 수행하였다. 연구 결과 재료의 인장 강도가 증가함에 따라 탄성 변형이 증가하며 소성 변형 능력이 저하됨으로 I-거더의 휨연성이 현저하게 감소하는 것으로 나타났다. 또한 소성모멘트 까지 선형거동하는 재료모델을 이용한 간략식을 통하여 연속교의 휨거동을 예측하여 유한요소해석 결과와 비교하였다.

  • PDF

Ductility of High-Strength Concrete Columns with High-Strength Lateral Ties (고강도 띠철근으로 구속된 고강도 콘크리트 기둥의 연성)

  • 문호권;이영호;양근혁;정헌수
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.261-267
    • /
    • 2001
  • The objective of this experimental study is to find the allowable level of axial load to give the proper flexural ductility according to the yield strength of lateral ties, and the distribution and amount of longitudinal bars used in confined high-strength concrete columns. Twelve concrete columns with a 20 cm square section and 80 cm high were tested under hi-axial loads. It was observed that the ductility tends to be improved at the axial loads not less than 0.4f$\_$ck/A$\_$g/. The utilization of high-strength ties in accordance with the ACI 318-99 can cause the brittle failure due to the wide tie spacing. Under the high level of axial loads not less than 0.4f$\_$ck/A$\_$g/. it is necessary for the buckling prevention of the longitudinal bars and the proper ductility improvement to use the high-strength ties with the consideration of the volumetric ratio and confinement type of the lateral ties, and the distribution of the longitudinal bars.

Cross-Sectional Compactness for Negative Moment Region of I-girder with High-Performance Steel (고강도강 적용 I-거더 부모멘트부의 조밀단면 기준 평가)

  • Cha, Sang-Ho;Joo, Hyun-Sung;Choi, Hyung-Ho;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.84.2-84.2
    • /
    • 2010
  • 본 연구는 소수주거더 교량에 적용된 I-거더에 고강도 강재인 HSB800 강재를 사용하였을 때, 휨 연성 R값을 이용하여 AASHTO LRFD(2007)의 조밀단면기준에 대한 경향성에 대해 수치해석적으로 수행되었다. 복부판 세장비, 플랜지 세장비, 비지지 길이를 변수로 하여 휨 연성 R값을 구해서 기존의 AASHTO LRFD(2007)의 조밀단면기준에 적용하여 휨 연성에 대한 경향성을 나타내었다.

  • PDF

Influence of ductility of reinforcement on the plastic hinge formation (철근의 연성이 소성힌지 생성에 미치는 영향)

  • Park, Dae-Gyun;Cho, Jae-Yeol;Park, Sung-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.97-100
    • /
    • 2008
  • Subjected to seismic action causing large deformation of bridge columns, the plastic hinge region is commonly formed in the column end zone. The deformation capacity of a concrete column can be expressed by using plastic hinge length. The mechanical properties of high-strength reinforcing steel is different from that of normal-strength steel and the mechanical properties of steel will influence the plastic hinge formation. Therefore, in other to accurately predict the deformation of concrete column using high-strength steel, the plastic hinge length can be expressed as a function of the mechanical properties of steel such as the tensile to yield strength ratio and the strain at ultimate state. However, little research has been conducted into the effect of mechanical properties of steel on the plastic hinge length. It was difficult to measure the plastic hinge length from the test results. Therefore, the plastic hinge length of concrete columns was investigated from the curvature profile. A numerical approach was used to study the effect of various parameters on plastic hinge length. Based on the results of the numerical parametric study, a new expression for plastic hinge length was proposed.

  • PDF

Evaluation on Moment-Curvature Relations and Curvature Ductility Factor of Reinforced Concrete Beams with High Strength Materials (고강도 재료를 사용한 철근콘크리트 보의 모멘트-곡률관계 및 곡률연성지수 평가)

  • Lee, Hyung-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.283-294
    • /
    • 2013
  • The high strength materials have been more widely used in reinforced concrete structures, specially, the reinforcing steel is permitted to used in RC structures up to yielding strength of 600 MPa. The strength of materials in RC beam section effects on the behavior and ductility of the RC members. In this study, the numerical analysis has been conducted to obtain the complete moment-curvature relation and the curvature ductility factor for the rectangular RC beams sections under the various reinforcement conditions and the effects of concrete strength, yield strength of reinforcement steel on the behavior and the curvature ductility factor of RC beam sections have been evaluated. The compressive strength of concrete and yield strength of steel have effected in various manner on the behavior and the curvature ductility factor of RC beam sections under reinforcement conditions. In the case of beam sections with equal resisting moment. the curvature ductility factor of RC beam section decreased with an increase in the yield strength of steel and increased with an increase in the concrete strength. When the yield strength of steel increased from 400 MPa to 600 MPa, the curvature ductility factor reduced about 30% and as the concrete strength increased from 30 MPa to 70 MPa, the curvature ductility factor of RC beam section increased about 3 times.

Flexural Behavior of High-strength Concrete Beams of 90 MPa According to Curing Temperature (양생온도에 따른 90 MPa 수준의 고강도 철근 콘크리트 보의 휨거동)

  • Hwang, Chul-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.134-140
    • /
    • 2017
  • In this study, the flexural behavior of high strength concrete members with different curing condition of 90 MPa of compressive strength was investigated. Experimental parameters included normal and low temperature curing conditions, tensile steel amount and concrete compressive strength. 8 beam members were fabricated and flexural tests were carried out. Crack spacing, load-deflection relation, load-strain relation and ductility index were determined. Experimental results show that as the amount of rebar increases, the number of cracks increases and the crack spacing decreases. The higher the concrete strength, the smaller the number of cracks, but the effect is significantly smaller than the amount of rebar. As a result of comparison with the proposed average crack spacing in the design criteria, the experimental results are slightly larger than the results of the proposed formula, but the proposed formula does not reflect the concrete strength and curing conditions. The ductility index of normal temperature cured members was 3.36~6.74 and the ductility index of low temperature cured members was 1.51~2.82. The behavior of low temperature cured members was found to be lower than that of normal temperature cured members. As a result of comparing the ductility index with the existing studies similar to the experimental members, the ductility index of the high strength concrete member was larger than the ductility index of the ordinary strength concrete of the previous study. Further research is needed to understand more specific results.

Marine Safety Technology using Highly Advanced M&S System (고도 정밀 M&S 시스템을 이용한 해양안전기술)

  • Lee, Sang-Gab
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.140-141
    • /
    • 2014
  • 최근 대용량 고속 컴퓨터의 출현과 고도 비선형 동적 해석 소프트웨어가 개발됨에 따라 안전사고 규명와 안전설계 등에 고도 정밀 Modeling & Simulation(M&S) 시스템이 널리 적용되고 있다. 특히 해양안전은 천배의 밀도를 갖는 해양에서의 내충돌 및 내충격 응답을 실선규모로 규명 분석하여야 할 것이다. 이를 위해서는 고도 정밀 M&S 시스템에 유체-구조 연성(Fluid-Structure Interaction, FSI) 해석기법을 적용하여야 보다 정확하고 합리적인 안전성을 평가할 수 있다. 여기서는 이러한 고도 정밀 M&S 시스템을 적용한 해양안전기술의 적용 분야를 소개하고자 한다.

  • PDF