• Title/Summary/Keyword: 고에너지 X-ray

Search Result 173, Processing Time 0.027 seconds

Assessment of Neutron Skyshine Dose in a Cargo Inspection Facility Using High Energy X-ray (고에너지 X-ray를 이용한 화물검색시설에서의 중성자 Skyshine 방사선량률 평가)

  • Cho, Young-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.27-31
    • /
    • 2008
  • The radiation protection measures for the photoneutrons are one of the most important issue of radiation safety in high energy X-ray facilities. When the photoneutrons are released from the facility, the general public as well as occupational workers are exposed to unexpected radiations by neutron skyshine effect. In this study, the photoneutron inventory are calculated using monte carlo mothed, and the neutron skyshine dose rate is assessed using the inventory. A 9MeV X-ray cargo inspection facility is considered as a reference facility.

  • PDF

X-ray Rocking Curve Analysis of Post-Annealed 3 MeV P+ Implanted Silicon (3MeV P+ 이온주입된 실리콘의 열처리에 따른 X-ray Rocking Curve 분석)

  • 조남훈;장기완;김창수;이정용;노재상
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.1
    • /
    • pp.109-117
    • /
    • 1995
  • 고에너지 이온주입시 격자결함의 생성 및 열처리 거동이 double crystal X-ray와 단면 TEM을 사용하여 연구되었다. 3MeV P+ 이온주입한 실리콘의 DCXRD 분석 결과조사량 증가에 따라 모재 내의 변형량은 증가하였다. HRTEM 분석 결과 고에너지 이온주입시 결함은 표면 부근에 희박하고 Rp 부근에 집중되어 있었다. 또한 이온주입 상태의 결함층은 dark band의 형태로 존재하였으며 열처리시 이차결함은 이곳으로부터 생성됨이 관찰되었다. 3MeV P+,$1X1015extrm{cm}^2$의 조건으로 이온주입된 실리콘 시편의 열처리에 따른 X-ray rocking curve 분석을 통하여 열처리 온도가 $550^{\circ}C$에서 $700^{\circ}C$로 증가함에 따라 모재 내부의 최대 변형량이 7X10-4에서 2.9X10-4으로 감소함이 관찰되었다. 특히 $550^{\circ}C$ 열처리한 시편의 경우 표면으로부터$-1.5mu$m 영역에 작은 변형층이 넓게 잔존하였으며 열처리온도를 $700^{\circ}C$로 증가한 경우 제거되었다. 이온주입시 생성된 일차결함들은 $700^{\circ}C$ 열처리시 $60^{\circ}$ 전위와 <112> 막대 모양 결함, $1000^{\circ}C$ 열처리시 <110>방향의 전위루프로 열처리 조건에 따라 여러 가지 모양의 이차결함으로 변화하였다. 고에너지 이온주입에 의해 발생한 이차결함은 고온에서도 안정하여 고온 열처리에 의한 제거가 용이하지 않았다.

  • PDF

The Change of Collected Light According to Changing of Reflectance and Thickness of CdWO4 Scintillator for High Energy X-ray Imaging Detection (고에너지 X-선 영상검출을 위한 CdWO4 섬광체 두께와 반사체의 반사율 변화에 따른 광 수집량의 변화)

  • Lim, Chang Hwy;Park, Jong-Won;Lee, Junghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1704-1710
    • /
    • 2020
  • The high-energy X-ray imaging detector used for container inspection uses a thick scintillator to effectively acquire X-rays. X-ray incident on the scintillator is generally up to 9MeV. Therefore, to effectively collect X-ray, it is necessary to use a thick scintillator. To collect the light generated by the reaction between X-ray and scintillator, an optical-sensor must be combined with the scintillator. In this study, a study on the design conditions of the detector using a CdWO4 and a small sensor is described. To calculate the collected light according to the change of the scintillator thickness and the reflectance of surface, MCNP6 and DETECT2000 were used. As a result of calculating, it was confirmed that when the reflectance of the surface was low, it was appropriate to select a scintillator with a thickness of 15 to 20-mm, but as the reflectance increased, it was confirmed that it was appropriate to select a CdWO4 with a thickness of 25 to 30-mm.

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.

Development of High Energy X-ray Dose Measuring Device based Ion Chamber for Cargo Container Inspection System (이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발)

  • Lee, Junghee;Lim, Chang Hwy;Park, Jong-Won;Lee, Sang Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1711-1717
    • /
    • 2020
  • X-ray of up to 9MeV are used for container inspection. X-ray intensity must be maintained stably regardless of changes in time. If dose is not constant, it may affect the image quality, and as a result, may affect the inspection of abnormal cargo. Therefore, to acquire high-quality images, continuous dose monitoring is required. In this study, the ion-chamber based device was developed for monitoring the dose change in high-energy x-ray. And to estimate the performance of signal-processing device change according to the environmental change, the output changing due to the change of temperature and humidity was observed. In addition, verification of the device was performed by measuring the output change. As a result of the measurement, there was no significant difference in performance due to changes in temperature and humidity, and the change in output according to the change in exposure was linear. Therefore, it was found that the developed device is suitable for the dose monitoring of high-energy x-ray.

DNA Damage by X-ray and Low Energy Electron Beam Irradiation (X선과 저에너지 전자선에 의한 DNA 손상)

  • Park, Yeun-Soo;Noh, Hyung-Ah;Cho, Hyuck;Dumont, Ariane;Ptasinska, Sylwia;Bass, Andrew D.;Sanche, Leon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • We observed DNA damages as a function of mean absorbed dose to identify the indirect effect of high-energy radiation such as x-ray. Monolayer films of lyophilized pGEM-3Zf(-) plasmid DNA deposited on tantalum foils were exposed to Al $K{\alpha}$ X-ray (1.5 keV) for 0, 3, 7 and 10 min, respectively, in a condition of ultrahigh vacuum state. We compared DNA damages by X-ray irradiation with those by 3 eV electron irradiation. X-ray photons produced low-energy electrons (mainly below 20 eV) from the tantalum foils and DNA damage was induced chiefly by these electrons. For electron beam irradiation, DNA damage was directly caused by 3 eV electrons. Irradiated DNA was analyzed by agarose gel electrophoresis and quantified by ImagaQuant program. The quantities of remained supercoiled DNA after irradiation were linearly decreased as a function of mean absorbed dose. On the other hand, the yields of nicked circular (single strand break, SSB) and interduplex crosslinked form 1 DNA were linearly increased as a function of mean absorbed dose. From this study, it was confirmed that DNA damage was also induced by low energy electrons ($0{\sim}10\;eV$) even below threshold energies for the ionization of DNA.

KCl Crystal Growth and High Energy X Ray Expose of Properties (KCl 단결정의 성장 및 고 에너지 X선 조사 특성)

  • Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: X ray irradiates material for dose distribution confirmation through material color variation to evaluate about possibility. Materials and Methods: That is rare earth material to pure KCl and KCl impurity Eu adding 0.5mol% by Czochralski method each single crystal grow and observed color variation of KCl X ray irradiation use of linear accelerator. Results: High energy X ray irradiation KCl:Eu show the blue fluorescence with purple color that pure KCl single crystal can confirm by show was not observed, but was colored violet. Conclusion: Colors variation of KCl founds stable color center from radiation and this color variation will be used usefully to X ray measurement material and phantom.

  • PDF

Material Estimation Method Using Dual-Energy X-Ray Image for Cargo Inspection System (화물 검색 시스템을 위한 듀얼 에너지 X-ray 검색기 영상을 이용한 물질 추정 방법)

  • Lee, TaeBum;Kang, HyunSoo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2018
  • This paper presents a material estimation method using dual-energy X-ray images generated as a result of cargo inspection system in MeV region. We use new discrimination curve using logarithmic function rather than four discrimination curves commonly used in existing estimation algorithms. We also propose an atomic number estimation using the probability distribution of the logarithmic curve rather than linear interpolation. When the probability distribution is used as a weight, we used two methods of using the weight for the two nearest reference materials and the weight for all the reference materials. Experimental results showed that the atomic number estimation of materials using the probability distribution as a weight is more accurate than the existing methods. In order to visualize the estimated atomic number, the HSI model was used for color the resulting image.

Comparison of Beam Quality Index of High Photon Beam (고에너지 광자선의 선질 지표에 관한 비교)

  • 신동오;지영훈;박성용;박현주;김회남;홍성언;권수일;서태석;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1998
  • It is necessarily to evaluate the energy of X-ray emitted from linear accelerator in order to determine the accurate absorbed dose. The method of direct measurement for x-ray energy is very difficult and impractical. Therefore the method of using beam quality index is generally used. Several dosimetry protocols recommend the use of quality indices such as depth of dose maximum at radiation central axis, dose gradient, and dose level. The linear accelerator manufactures follow the recommendation as dosimetry protocols. The study was performed for us to select the most suitable parameter among the Quality indices as described above. For photon beams of 4, 6, 10, 15, and 21 MV nominal energies produced by four kinds of accelerators(Mitsubishi, Scanditronix, Siemens, Varian) in eleven institutions, We evaluated the x-ray energies obtained by the Quality indices as recommended by several dosimetry protocols and manufactures. Results showed that there were energy spreads according to the same accelerators and Quality indices even though nominal energies were same. It appeared that the percent depth dose at 10 cm (D$_{10}$(%)) gave the smallest deviation and spread of energies. As energies increased, the energy deviation increased for all the quality indices. It is desirable for the use of unified quality index to compare the evaluation of beam quality at different institutions.

  • PDF

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF