• Title/Summary/Keyword: 고압화학

Search Result 294, Processing Time 0.021 seconds

A Study on Quantitative Risk Analysis & Model Application for Hydrogen Filling Center (수소충전시설에 대한 정량적 위험성 평가 및 모델적용에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.87-101
    • /
    • 2012
  • In gas industries, the potential risks of serious accidents have been increased due to high technology application and process complexities. Especially, in case of gas-related accidents, the extent of demage is out of control since gas plants handle and produce combustible, flammable, explosive and toxic materials in large amounts. The characteristics of this kind of disaster is that accident frequency is low, while the impact of damage is high, extending to the neighboring residents, environment and related industries as well as employees involved. The hydrogen gases treated important things and it used the basic material of chemical plants and industries. Since 2000, this gas stood in the spotlight the substitution energy for reduction of the global warming in particular however it need to compress high pressure(more than 150 bar.g) and store by using the special cylinders due to their low molecular weight. And this gas led to many times the fire and explosion due to leak of it. To reduce these kinds of risks and accidents, it is necessary to improve the new safety management system through a risk management after technically evaluating potential hazards in this process. This study is to carry out the quantitative risk assesment for hydrogen filling plant which are very dangerous(fire and explosive) and using a basic materials of general industries. As a results of this risk assessment, identified the elements important for safety(EIS) and suggested the practical management tools and verified the reliability of this risk assessment model through case study of accident.

Numerical Simulation of CNTs Based Solid State Hydrogen Storage System (탄소나노튜브 기반의 고체수소저장시스템에 관한 전산해석)

  • Kim, Sang-Gon;HwangBo, Chi-Hyung;Yu, Chul Hee;Nahm, Kee-Suk;Im, Yeon-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.644-651
    • /
    • 2011
  • Storing hydrogen in solid state hydride is one of the best promising methods for the future hydrogen economy. The total performance of such systems depends on the rate at which the amount of mass and heat migration is supplied to solid hydride. Therefore, an accurate modeling of the heat and mass transfer is of prime importance in optimizing the design of such systems. In this work, Hydrogen storage in Pt-CNTs hydrogen reactor has been intensively investigated by solving 2 dimensional mathematical models. Using a CFD computer software, systematic studies have been performed to elucidate the effect of heat and mass transfer during hydrogen charging periods. It was revealed that the optimized design of hydrogen storage vessel can prevent the increase of system temperature and the charging time due to the convective cooling effects inside the vessels at even high charging pressure. Because none has reported the critical issues of heat and mass transfer for CNT based hydrogen storage system, this work can support the first insight of the optimal design for solid state hydrogen storage system based on CNT in the near future.

Dimethyl Carbonate Synthesis by Methanol Oxidative Carbonylation (메탄올 산화 카르보닐화에 의한 디메틸카보네이트 합성)

  • Nam, Jeong-Kwang;Cho, Deug-Hee;Suh, Jeong-Kwon;Kim, Seong-Bo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.530-534
    • /
    • 2011
  • The synthesis of dimethyl carbonate by liquid phase oxidative carbonylation of methanol was studied under batch reaction system. Reaction factors such as effect on various metals, anion containing in copper catalyst, temperature, carbon monoxide and oxygen molar ratio and copper content were investigated. In particular $CuCl_2{\cdot}2H_2O$ showed the excellent of the methanol conversion 65.2%, DMC selectivity 96.6% reaction condition under 1.0 g, $150^{\circ}C$, MeOH/CO/$O_2$=0.2/0.215/0.05 (molar ratio). $CuCl_2$ led to corrosion of the reactor. Thus, a new catalyst system using supports was investigated to resolve these corrosion problem. Influence on various supports were examined and copper catalyst supported on zeolite Y showed the most excellent activity on the formation of dimethyl carbonate. The amount of Fe dissolved during the reaction using ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometer) was compared with catalysts, calcined Cu/zeolite Y showed the lower value below 5% than $CuCl_2-2H_2O$.

Maximum Pressure and the Blast Wave Analysis of a Amount of HMX (HMX의 양에 따른 최대압력 및 폭풍파속도 분석)

  • Kwon, Hweeung;Tak, Kyongjae;Kim, Junghwan;Oh, Min;Chae, Jooseung;Kim, Hyeonsoo;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.706-712
    • /
    • 2014
  • Explosives are reactive material that contain a great amount of high potential energy. They produce detonation if released suddenly, accompanied by the production of strong light, high heat, great noise and high pressure. Damage at surrounding detonation point is affected by high pressure and blast wave for explosives detonation. Consequently, analysis of pressure and blast wave is very important. This study focuses on the analysis of maximum overpressure and blast wave of explosives for safety assurance. First of all, four cases of the amount of HMX were selected. Secondly, maximum pressure and blast wave were calculated through detonation simulation along with a set of TNT and HMX quantities. The peripheral effect of detonation point was analyzed by calculating overpressure and absolute velocity and considering detonation occurred in the center of geometry by HMX. Also, maximum overpressure and blast wave of HMX were compared to equivalent amount of TNT, which was taken as a base case and verified through theoretical HMX graph. This study contributes to the base case for overpressure and blast wave of complex gunpowder containing HMX.

Synthesis and Thermal Properties of PPS/PPSS Copolymer (PPS/PPSS 공중합체의 합성 및 열적 성질)

  • Park, Lee-Soon;Lee, Tae-Hyung;Kwak, Kyu-Dae;Haw, Jung-Rim
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.440-444
    • /
    • 1998
  • Poly(phenylene sulfide-co-phenylene sulfide sulfone), PPS/PPSS copolymers were synthesized from p-dichlobenzene(DCB), p-dibromobenzene(DBB), p-diiodobenzene(DIB), 4-chlorophenyl sulfone(CPS) and sodium sulfide as comonomers under high temperature and pressure utilizing N-methyl-2-pyrrolidinone(NMP) as solvent. The yield of PPS/PPSS copolymer shoed maximum at $190^{\circ}C$ with [DBB]/[CPS] and [DIB]/[CPS] comonomer pair, while [DCB]/[CPS] pair exhibited maximum yield at $230^{\circ}C$. The change of yield is in the order of I>Br>Cl as leaving groups were in accordance with nucleophilic aromatic substitution reaction mechanism suggested for the synthesis of PPS type polymers. The molecular weight of PPS/PPSS copolymer was the highest($M_w=8,330g/mol$) with [DBB]/[CPS] comonomers in which [CPS] was 10 mole%. The PPS/PPSS copolymer made with 10 mole% of [CPS] showed about $15^{\circ}C$ higher $T_g$ and $15^{\circ}C$ lower $T_m$ than those of PPS homopolymer, which may be useful from the processing and thermal property point of view. The PPS/PPSS copolymer with 30 mole% of CPS or above did not exhibit Tm. The PPS/PPSS copolymer obtained with comonomer feed ratio of [DBB]/[CPS] = 95/5 mole% under $240^{\circ}C$ showed even higher molecular weight($M_w=10,300g/mole$) than PPS homopolymer made under similar reaction condition, retaining high crystallinity and thermal stability.

  • PDF

Gas Hydrate Exploration by using PCS(Pressre Core Sampler): ODP Leg 204 (압력코어를 이용한 가스 하이드레이트 탐사: ODP Leg 204)

  • Lee Young-Joo
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.165-176
    • /
    • 2005
  • Natural gas in deep sediment may occur in three phases based on the physical and chemical conditions. If the concentration of gas in pore water is less than the solubility, gas is dissolved. If the concentration of gas is greater than its solubility (water is saturated or supersaturated with gas), gas occurs as a fee gas below the gas hydrate stability Lone (GHSZ) and is present as solid hydrate within the GHSZ. The knowledge of gas concentration in deep sediment appears critical to determine the phase of natural gases and to understand the formation and distribution of gas hydrate. However, reliable data on gas concentration are usually available only from the upper section of marine sediment by the headspace gas technique, which is widely used for sampling of gases from the sediments. The headspace gas technique represents only a fraction of gases present in situ because sediments release most of the gases during recovery and sampling. The PCS (Pressure Core Sampler) is a downhole tool developed to recover a nominal $1{\cal}m$ long, $4.32{\cal}cm$ diameter core containing $1,465cm^3$ of sediment, pore water and gas at in situ pressure up to 68.9 MPa. During Leg 204, the PCS was deployed at 6 Sites. In situ methane gas concentration and distribution of gas hydrate was measured by using PCS tool. Characteristics of methane concentration and distribution is different from site to site. Distribution of gas hydrate in the study area is closely related to characteristics of in situ gas concentration measured by PCS.

Direct Incorporation of Carbon Dioxide to Poly(GMA) Using Quaternary Ammonium Salt Catalysts (4차 암모늄염 촉매를 이용한 Poly(GMA)에의 이산화탄소 직접 고정화)

  • Sung, Chung-Ki;Kim, Kyung-Hoon;Moon, Jeong-Yeol;Chun, Sung-Woo;Na, Suk-Eun;Park, Dae-Won
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.129-134
    • /
    • 1999
  • This study is related to the investigation of the direct incorporation of $CO_2$ to polymer using quaternary ammonium salt catalysts. Quaternary ammonium salts showed good catalytic activity of $CO_2$ fixation in the synthesis of poly[(1,3-dioxolane-2-oxo-4-yl)methyl methacrylate] [poly(DOMA)] by the direct incorporation of $CO_2$ to poly(glycidyl methacrylate)[poly(GMA)]. Among the salts tested, the ones with higher alkyl chain length and with more nucleophilic counter anion showed higher catalytic activity. The yield of carbon dioxide addition increased with the reaction temperature. Kinetic study was carried out by measuring the variation of $CO_2$, pressure in a high pressure batch reactor. The reaction rate was first order to the concentration of poly(GMA) and $CO_2$, respectively. The rate constant was $0.69L/mol{\cdot}h$ and Henry's constant of $CO_2$ in DMSO at $80^{\circ}C$ was $6.8{\times}10^{-4}mol/L{\cdot}KPa$.

  • PDF

Identifying Risk Management Locations for Synthetic Natural Gas Plant Using Pipe Stress Analysis and Finite Element Analysis (배관응력해석 및 유한요소해석에 의한 SNG플랜트의 리스크 관리 위치 선정)

  • Erten, Deniz Taygun;Yu, Jong Min;Yoon, Kee Bong;Kim, Ji Yoon
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.1-11
    • /
    • 2017
  • While they are becoming more viable, synthetic natural gas (SNG) plants, with their high temperatures and pressures, are still heavily dependent on advancements in the state-of-the-art technologies. However, most of the current work in the literature is focused on optimizing chemical processes and process variables, with little work being done on relevant mechanical damage and maintenance engineering. In this study, a combination of pipe system stress analysis and detailed local stress analysis was implemented to prioritize the inspection locations for main pipes of SNG plant in accordance to ASME B31.3. A pipe system stress analysis was conducted for pre-selecting critical locations by considering design condition and actual operating conditions such as heat-up and cool-down. Identified critical locations were further analyzed using a finite element method to locate specific high-stress points. Resultant stress values met ASME B31.3 code standards for the gasification reactor and lower transition piece (bend Y in Fig.1); however, it is recommended that the vertical displacement of bend Y be restricted more. The results presented here provide valuable information for future risk based maintenance inspection and further safe operation considerations.

A Study on the Adsorption Characteristics of Nitrogen and Oxygen on Ion Exchanged Zeolite Adsorbents (이온교환된 제올라이트 흡착제의 질소 및 산소 흡착 특성 연구)

  • Jeong, Heon-Do;Kim, Dong-Sik;Kim, Kweon-Ill
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.123-130
    • /
    • 2005
  • Zeolite X adsorbents with large surface area were prepared for using oxygen PSA adsorbent. Selective adsorption performance of nitrogen on the synthesized zeolite X adsorbent was improved by the cation exchange of adsorbent. The zeolite X which had over $650m^2/g$ surface area was synthesized at the conditions of $SiO_2\;:\;Na_2O\;:\;H_2O\;:\;Al_2O_3$ = 2.5 : 3.5 : 150 : 1 mole ratio, $98^{\circ}C$ temperature and 18 h synthesized time in 50 L reactor. The metal ions Li, Ag, Ca, Br, Sr, etc. were investigated for ion exchange with zeolite X. Ag ion was showed the highest ion exchange rate among these metal ions and all metal ions were exchanged with Na ion at equivalent rate. Compared with the NaX adsorbent, the ion exchanged zeolite X adsorbent remarkably improved its adsorption performance of nitrogen at the conditions of $10{\sim}40^{\circ}C$ temperature and 0~9 atm pressure. At an equilibrium pressure under 0.5 atm, adsorption performance of nitrogen on the ion exchanged zeolite adsorbent increased in the order of Ag > Li > Ca > Sr> Ba > K, whereas at an equilibrium pressure over 1 atm showed in the order of Li > Ag > Ca > Sr > Ba > K. Nitrogen/oxygen separation factor of Li ion exchanged zeolite X adsorbent was 13.023 at the partial pressure of nitrogen/oxygen gas mixture similar to air and $20^{\circ}C$ adsorption temperature.

친환경 평판 디스플레이 세정을 위한 $CO_2$ Snow Jet 세정공정 개발에 관한 연구

  • Jeong, Ji-Hyeon;Gang, Bong-Gyun;Kim, Min-Su;Lee, Jong-Myeong;Lee, Gyu-Pil;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.66.1-66.1
    • /
    • 2011
  • 반도체를 비롯하여 LCD, OLED와 같은 디스플레이 (FPD: Flat Panel Display) 분야는 국가 선도 사업으로써 발전을 거듭해오고 있다. 하지만 기술의 성숙도가 높아짐에 따라 최근 중국과 대만 업체와의 경쟁이 심화되고 있으며, 더불어 환경문제가 큰 이슈로 떠오르고 있어 신기술 개발을 통한 생산 수율 향상 및 친환경 공정 개발의 중요성이 커지고 있다. 반도체, 디스플레이 공정에서 생산 수율 저하의 주요 원인으로써 공정 중 발생하는 미세 오염 입자를 들수 있다. 반도체 및 디스플레이 공정에서 세정 기술은 전체 기술의 30% 이상을 차지하며 생산 수율 및 제품의 품질에도 큰 영향을 주는 공정이다. 세정 공정은 일반적으로 습식 세정 공정이 낮은 공정비용을 바탕으로 널리 적용되어 왔으나, 기판의 대형화와 패턴의 미세화에 따라 정밀한 세정 스펙이 요구되며 더불어 막대한 양의 초순수와 화학액의 사용으로 인한 공정비용 증가와 환경 규제 강화에 따른 폐수 처리의 문제에 직면하고 있다. 이에 따라 폐수의 양을 줄이며 건조공정을 필요로 하지 않아 공정비용을 줄일 수 있는 건식 세정 공정에 대한 연구가 활발히 진행 되고 있다. $CO_2$ snow jet 세정 기술은 건식 공정으로써 $CO_2$ 가스를 특수하게 제작된 분사 노즐에서 고압으로 가스를 분사하여 이 때 발생되는 순간적인 감압에 의한 단열 팽창으로 생성된 $CO_2$ snow 입자가 기판 표면의 오염물과 물리적 충돌을 하어 세정이 이루어지는 기술이다. 특히 $CO_2$ 세정은 환경과 인체에 무해하며 공정 후 바로 승화하기 때문에 추가적인 폐수처리 공정 등이 필요하지 않고, 건식 공정으로써 수세(Rinse) 공정을 필요로 하지 않기 때문에, 공정비용을 크게 줄일 수 있으며 물반점 발생을 방지 할 수 있는 친환경 건식 공정으로써의 장점을 가지고 있다. 본 연구에서는 자체적으로 개발한 $CO_2$ snow jet을 바탕으로 하여 다양한 공정조건을 변화시켜 세정효율을 측정하는 한편, 최적화 하기 위한 연구를 진행하였으며 더불어 $CO_2$ snow의 세정력을 정량적으로 평가하기 위한 연구를 진행하였다. 실험을 통해 가장 효과적으로 $CO_2$ snow 입자를 배출 할 수 있는 공정 조건으로써 5 bar의 캐리어 가스 압력을 사용하여, 세정력에 가장 큰 영향을 줄 수 있는 분사 노즐과 기판 사이의 거리 및 분사 노즐의 각도 등을 변화시켜 각 조건에 따른 세정효율을 평가하였다. 세정 오염물은 Silica, PSL 표준 입자(Duke scientific, USA)를 정량적으로 웨이퍼에 오염 시킨 후, 파티클 스캐너(Surfscan 6500, KLA-Tencor, USA)를 이용하여 세정 전 후의 오염입자 개수 변화를 통해 정량적으로 세정효율을 평가하였다. 본 연구를 통하여 $CO_2$ snow jet를 이용한 친환경 고효율 건식 세정 공정 메커니즘을 분석하였으며, 노즐과 기판 사이의 간격 및 분사 노즐의 각도 등을 최적화 한 세정 공정을 얻을 수 있었다.

  • PDF