• Title/Summary/Keyword: 고성

Search Result 5,785, Processing Time 0.028 seconds

A Study on the Construction Cost Risk through Analyzing the Actual Cost of Public Apartment (공공주택 실적공사비 분석을 통한 공사비 리스크에 관한 연구)

  • Yoon, Woo-Sung;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.65-78
    • /
    • 2011
  • Construction business, which is complex and long-term business, requires accurate estimation and verification in construction costs and payment procedure from project planning to the completion of construction phase. And more importantly, it is necessary to investigate and determine the risk factors related to construction costs during the entire process including design planning, construction drawings, and quantity calculating. But, currently, it is not seem to be adequate to cope with the risk and increased construction costs against the operational budget in terms of actual costs when screening and estimating the bidding cost of public apartment. Therefore, this study selected and analyzed 40 sites' report of construction completion account from 2004 to 2010 focused on the adequacy on the modification of contract and design planning and on the complication of the budget in the beginning of the project. This study deducted various risk causes and results by analyzing actual costs according to year, architectural area, region, construction cost and sale/lease classification. We could find out construction risk according to annual variation of government policy and economy, and also deducted risk items by construction characteristic according to region and architectural area. Study result, we first found out the problems of lowest price award system according to the construction costs. The weight of the cost increase risk was analyzed that subcontract and material costs are very high. Roof and tile work were analyzed highly in subcontract cost risk and reinforcing bar and cement were analyzed highly in material cost risk, among direct construction cost. Finally, this study results could be used in comparing the categories of the construction costs made by specific construction process, belonging to the construction costs, with the operational budget made in the beginning of the project that can enable to grasp unpredictable risks over the construction costs and making quantitative analysis for it through analyzing the range of fluctuation and variations led by the fluctuations in the actual construction costs.

Influence of Curing Conditions on Volumetric Changes in Concrete (양생 조건이 콘크리트의 체적 변화에 미치는 영향)

  • Lee, Kwang-Myong;SunWoo, Joo-Yeun;Lee, Hoi-Keun;Khayat, Kamal H.
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.331-338
    • /
    • 2006
  • This paper presents the experimental results on volumetric changes in ordinary portland cement concrete made with various water-to-cement ratios(W/C's) ranging from 0.32 to 0.50 and cured in low different conditions. Curing regimes employed in this work were designed to exhibit autogenous and drying shrinkage as well as swelling of concrete. The concrete avoided any moist evaporation(Regime f showed only autogenous shrinkage and the lower the W/C, the feater the autogenous shrinkage. The concrete exposed to air drying conditions at $20{\pm}1^{\circ}C$ and $60{\pm}3%$ RH after 6-day water curing at $20{\pm}1^{\circ}C$(Regime II) swelled and then started to shrink. The maximum swelling value of concrete developed in water curing was between 15 and $40{\pm}10^{-6}$, and the greatest total shrinkage(autogenous+drying shrinkage) was obtained for the mixture made with W/C of 0.32. The concrete let to air drying conditions(Regime III) showed greater total shrinkage compared to the concrete cured in Regime II. The concrete exposed to air drying condition after 6-day sealed curing(Regime IV) exhibited slightly smaller total shrinkage than that of the concrete cured in Regime III. Net drying shrinkage that can be derived from the results of Regime I, III, and IV increased as the W/C increased despite of similar total shrinkage. This result indicated that drying shrinkage governs total shrinkage of high-W/C concretes. In other words, a portion of autogenous shrinkage in total shrinkage increased in low-W/C concretes. Therefore, it should be controlled in terms of cracking potential. Finally, total shrinkage of high-strength and high-performance concrete made with low W/C can be effectively reduced by appropriate early moisture curing.

An Experimental Study on the Required Performances of Roof Concrete Placed in the In-ground LNG Storage Tank (지하식 LNG 저장탱크의 지붕 콘크리트의 요구성능에 관한 실험적 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.339-345
    • /
    • 2013
  • This study is to derive from the required performances and the optimum mix proportion of the roof concrete placed in the in-ground LNG storage tank with a capacity of 200000 $m^3$, and propose the actual data for site concrete work. The concrete placing work without sliding and segregation in the fresh concrete condition is very important because the slope of domed roof is varied in the large range by its curvature. Also the control of hydration heat and the strength development at test ages are classified with massive section about 1.4 m thick and considered to the pre-stressing work and removal of air support after concrete placing work. Considering above condition, slump range is selected $100{\pm}25$ mm under the slope $20^{\circ}$ and $150{\pm}25$ mm over the slope $20^{\circ}$ s until 60 minutes of elapsed time. Also, the roof concrete is satisfied with compressive strength range including design strength at 91 days (30 MPa), pre-stressing work at 7 days (10 MPa), air support removal work at 21 days (14 MPa). Replacement ratio of limestone powder is determined by confined water ratio test and main design factors include water-cement ratio (W/C), sand-aggregate ratio and dosage of admixture. As test results, the optimum mix proportion of the roof concrete used low heat cement is as followings. 1) Replacement ratio of limestone powder 25% by confined water ratio test 2) Water-cement ratio 57.8% 3) Sand-aggregate ratio 42.0%. Also, test results for the adiabatic temperature rising test is satisfied with its criteria and shown the lower value compared to preceding storage tank (TK-13, 14). These required performances and the optimum mix proportion is to apply the actual construction work.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

Developing and Applying the Questionnaire to Measure Science Core Competencies Based on the 2015 Revised National Science Curriculum (2015 개정 과학과 교육과정에 기초한 과학과 핵심역량 조사 문항의 개발 및 적용)

  • Ha, Minsu;Park, HyunJu;Kim, Yong-Jin;Kang, Nam-Hwa;Oh, Phil Seok;Kim, Mi-Jum;Min, Jae-Sik;Lee, Yoonhyeong;Han, Hyo-Jeong;Kim, Moogyeong;Ko, Sung-Woo;Son, Mi-Hyun
    • Journal of The Korean Association For Science Education
    • /
    • v.38 no.4
    • /
    • pp.495-504
    • /
    • 2018
  • This study was conducted to develop items to measure scientific core competency based on statements of scientific core competencies presented in the 2015 revised national science curriculum and to identify the validity and reliability of the newly developed items. Based on the explanations of scientific reasoning, scientific inquiry ability, scientific problem-solving ability, scientific communication ability, participation/lifelong learning in science presented in the 2015 revised national science curriculum, 25 items were developed by five science education experts. To explore the validity and reliability of the developed items, data were collected from 11,348 students in elementary, middle, and high schools nationwide. The content validity, substantive validity, the internal structure validity, and generalization validity proposed by Messick (1995) were examined by various statistical tests. The results of the MNSQ analysis showed that there were no nonconformity in the 25 items. The confirmatory factor analysis using the structural equation modeling revealed that the five-factor model was a suitable model. The differential item functioning analyses by gender and school level revealed that the nonconformity DIF value was found in only two out of 175 cases. The results of the multivariate analysis of variance by gender and school level showed significant differences of test scores between schools and genders, and the interaction effect was also significant. The assessment items of science core competency based on the 2015 revised national science curriculum are valid from a psychometric point of view and can be used in the science education field.

Quality Characteristics of Ice Creams using Tarak (타락을 이용한 아이스크림류의 품질 특성)

  • Ko, Seong-Hee;Han, Young-Sook;Yoon, Hyun-Geun;Jang, Sung-Sik;Myoung, Kil-Sun;Kim, Soo-A;Shim, Jae-Hun;Park, Seon-Yeong;Lee, Hye-Jin;Lee, Kyung-Yeoun
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.91-101
    • /
    • 2014
  • This study examines ice cream products with higher preference as dessert food using Tarak which is Korean traditional fermented milk (sherbet 1 kind, ice milk 2 kinds(IM-2, IM-4), ice cream 1 kind (IC-6)), and investigates the quality characteristics of each Tarak ice cream. For viscosity of the mix for Tarak ice creams, sherbet showed the lowest, and IC-6 showed the highest, significantly. For overrun, at 10 minutes, IC-6 with high milk fat content showed a higher value, and at the final 30 minutes, there was no significant difference among all samples. For melting point, IC-6 showed the highest and sherbet showed the lowest. For number of lactic acid bacteria, sherbet showed 7.32 Log CFU/g and IM-2, IM-4 and IM-6 showed 8.35~8.49 Log CFU/g, not showing significant difference. For sensory test of Tarak ice creams, IC-6 showed milk flavor highest, 4.10, and for sourness, sherbet showed 4.20 and IM-2 showed 4.10. For sweet taste, IC-6 showed the highest 5.05, and for bitter, IC-6 showed the lowest, 1.65. For the degree of creaminess, IC-6 was assessed significantly higher as 4.60 and body sense was also assessed higher as 5.05. For acceptance of appearance, taste, flavor and texture, IC-6 was assessed significantly higher than the other samples and for overall acceptability, IC-6 was assessed the highest at 5.15, sherbet showed 3.75, IM-2 showed 3.05 and IM-4 showed 2.50. This suggests that for Tarak ice creams, sensory preference of ice creams with high milk fat content or sherbet with non milk fat content is high.

A 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS ADC Based on High-Accuracy Integrated Capacitors (높은 정확도를 가진 집적 커페시터 기반의 10비트 250MS/s $1.8mm^2$ 85mW 0.13un CMOS A/D 변환기)

  • Sa, Doo-Hwan;Choi, Hee-Cheol;Kim, Young-Lok;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.58-68
    • /
    • 2006
  • This work proposes a 10b 250MS/s $1.8mm^2$ 85mW 0.13um CMOS A/D Converter (ADC) for high-performance integrated systems such as next-generation DTV and WLAN simultaneously requiring low voltage, low power, and small area at high speed. The proposed 3-stage pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The input SHA maintains 10b resolution with either gate-bootstrapped sampling switches or nominal CMOS sampling switches. The SHA and two MDACs based on a conventional 2-stage amplifier employ optimized trans-conductance ratios of two amplifier stages to achieve the required DC gain, bandwidth, and phase margin. The proposed signal insensitive 3-D fully symmetric capacitor layout reduces the device mismatch of two MDACs. The low-noise on-chip current and voltage references can choose optional off-chip voltage references. The prototype ADC is implemented in a 0.13um 1P8M CMOS process. The measured DNL and INL are within 0.24LSB and 0.35LSB while the ADC shows a maximum SNDR of 54dB and 48dB and a maximum SFDR of 67dB and 61dB at 200MS/s and 250MS/s, respectively. The ADC with an active die area of $1.8mm^2$ consumes 85mW at 250MS/s at a 1.2V supply.

A 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS ADC for Digital Multimedia Broadcasting applications (DMB 응용을 위한 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D 변환기)

  • Cho, Young-Jae;Kim, Yong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.37-47
    • /
    • 2006
  • This work proposes a 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D Converter (ADC) for high-performance wireless communication systems such as DVB, DAB and DMB simultaneously requiring low voltage, low power, and small area. A two-stage pipeline architecture minimizes the overall chip area and power dissipation of the proposed ADC at the target resolution and sampling rate while switched-bias power reduction techniques reduce the power consumption of analog amplifiers. A low-power sample-and-hold amplifier maintains 10b resolution for input frequencies up to 60MHz based on a single-stage amplifier and nominal CMOS sampling switches using low threshold-voltage transistors. A signal insensitive 3-D fully symmetric layout reduces the capacitor and device mismatch of a multiplying D/A converter while low-noise reference currents and voltages are implemented on chip with optional off-chip voltage references. The employed down-sampling clock signal selects the sampling rate of 25MS/s or 10MS/s with a reduced power depending on applications. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.42LSB and 0.91LSB and shows a maximum SNDR and SFDR of 56dB and 65dB at all sampling frequencies up to 2SMS/s, respectively. The ADC with an active die area if $0.8mm^2$ consumes 4.8mW at 25MS/s and 2.4mW at 10MS/s at a 1.2V supply.

A Descriptive Statistical Analysis of the Hospitalized Patients with Low Back Pain in Departments of Korean Rehabilitation Medicine of Korean Medicine Hospitals (한국의 5개 한의과대학 부속한방병원 재활의학과의 요통 입원 환자에 대한 후향적 기술통계분석 - 입원 기간, 상병명, 치료 방법을 중심으로 -)

  • Maeng, Tae-Ho;Kim, Jongyeon;Yi, Woon-Sup;Chung, Won-Seok;Ko, Youn-Seok;Lee, Jung-Han;Shin, Byung-Cheul;Cha, Yun-Yeop;Go, Ho-Yeon;Sun, Seong-Ho;Jeon, Chan-Yong;Jang, Bo-Hyoung;Song, Yun-Kyung;Ko, Seong-Gyu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.213-223
    • /
    • 2013
  • Objectives Low back pain (LBP) is one of the most common reason for people in Korea to visit Korean medical institutions. To assess actual amounts of use in the treatment of LBP in Korean medicine and to provide objective base line data for policy decision making, research regarding the current state of LBP patients' treatment in Korean medical institutions are in need. Methods The current study was designed as a retrospective chart review to investigate descriptive characteristics of LBP patients. The clinical records of 304 patients who were hospitalized for the treatment of LBP in Korean rehabilitation medicine inpatient clinics of five different Korean medicine hospitals were analyzed. The percentage of patient characteristics such as sex, age, average duration of admission, insurance type, diagnosed LBP related disease code, and rates of interventions applied were assessed. Results 1. The female sex was significantly predominant among patients with LBP : 105 patients (34.5%) were male and 199 patients (65.5%) were female. Percentage of the patients' age appeared as followed : 76 people (25.0%) were in their 50s, 64 people (21.1%) were in their 40s, 51 people (16.8%) were in their 30s, 37 people (12.2%) were in their 60s, and 33 people (10.9%) were in their 70s. Approximately half of the total LBP patients investigated were older than 50. 2. The average duration of admission was 16.2 days. Approximately one third (30.3%) of the patients were hospitalized for 8 to 14 days. 3. Female patients tended to stay admitted in hospitals slightly longer than male patients. Elderly (age 60~79) patients stayed in hospitals longer (17.8 days) compared to younger (age 20~39) patients (13.5 days). 4. More than half of the patients (171 cases, 56.3%) had their hospital bills covered with automobile insurance. 40.1% (122 cases) of the patients had medical insurance to cover their hospital bills. The average duration of admission of patients who had automobile insurance was 14.2 days, while that of the patients who had medical insurance was 18.4 days. 5. "Sprain and strain of the lumbar spine and pelvis" was the most commonly used (195 cases, 64.1%) disease code in patients with LBP. Patients diagnosed as "lumbar and other intervertebral disc disorders with radiculopathy" required the longest admission duration (22.1 days). 6. Herbal medication was applied to all of the patients during admission. Acupuncture was applied to all of the patients except one case diagnosed as spinal stenosis. Physical therapy, cupping therapy, moxibustion therapy, chuna therapy, and pharmacopuncture therapy were applied to 94.7, 92.8, 85.2, 83.9, and 49.7% of the patients, respectively. 7. There were certain differences among Korean medicine hospitals in terms of the LBP patients' duration of admission, type of insurance, frequency of the disease code use, type of intervention applied. Conclusions It is thought that the current study can be used as reference data in assessing the current state of LBP treatment in Korean rehabilitation medicine and a basis for future research. Provided improvements of certain limitations of the current study in future researches, such data would act as better base line data in policy decision making.

A Review of Questionnaire for the Clinical Trials on Chronic Low Back Pain (만성 요통 임상연구에 사용된 설문지 현황 고찰)

  • Kim, Doo-Hee;Shin, Woo-Suk;Lee, Jin-Won;Park, Won-Hyung;Cha, Yun-Yeop;Ko, Youn-Seok;Lee, Jung-Han;Chung, Won-Suk;Shin, Byung-Cheul;Song, Yun-Kyung;Go, Ho-Yeon;Sun, Seong-Ho;Jeon, Chan-Yong;Jang, Bo-Hyoung;Ko, Seong-Gyu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.95-115
    • /
    • 2013
  • Objectives The aim of this review is to provide fundamental data for low back pain scales which can be used in clinical trial. Methods We investigated the latest studies on chronic low back pain via PubMed. And we also investigated domestic studies through "http://oasis.kiom.re.kr". 95 research papers were analyzed. Scales were classified into pain scale, function scale, generic health status scale and psychological scale. Results 1) According to foreign clinical studies, Visual Analog Scale (VAS) and Numerical Rating Scale (NRS) were used 18 times as pain scale. Oswestry Disability Index (ODI) was used 20 times as function scale, Roland-Morris Disability Questionnaire (RMDQ) was 17, and Hannover Functional Ability Questionnaire (HFAQ) was used 3 times. 36-item Short Form Health Survey (SF-36) was used 13 times as generic health status scale, Euroqol-5 Dimentions Questionnaire (EQ-5D) was 11, and 12-item Short Form Health Survey (SF-12) was used 3 times. Fear-Avoidance Beliefs Questionnaire (FABQ) was used 9 times as psychological scale, Pain Catastrophizing Scale (PCS) and Tampa Scale for Kinesiophobia (TSK-R) both were used 3 times. 2) According to domestic clinical studies, VAS was used 37 times as pain scale, NRS was 11, and Short Form McGill Pain Questionnaire (SF-MPQ) was used 6 times. ODI was used 30 times as function scale, RMDQ was 2 times only. SF-36 was used once as generic health status scale and Beck's Depression Inventory (BDI) was used 3 times as psychological scale. Conclusions We recommend VAS or NRS as a measure to evaluate pain, and ODI as a measure to evaluate functional disability. And we also recommend SF-36 or SF-12 and EQ-5D as a measure to evaluate generic health status. Finally, we recommend FABQ for use in measuring psychological scale.