• Title/Summary/Keyword: 고성능 액체크로마토그래피

Search Result 32, Processing Time 0.018 seconds

Reversed-Phase Ion-Pair High Performance Liquid Chromatographic Elution Behavior of Noble Metal-Thiacrown Ether Complexes (귀금속-티아크라운에테르 착물들의 역상 이온쌍 고성능 액체크로마토그래피 용리거동)

  • Chung, Yong Soon;Kim, Dong Won;Lee, Kang Woo;Kim, Chang Seok
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.416-421
    • /
    • 1998
  • In the reversed-phase ion-pair high performance liquid chromatographic (RPIP-HPLC) elution behavior of noble metal-thiacrown ether complexes, the effects of the concentration of ion-pairing reagent and kind of ligands were studied. It was found that the less the number of atoms in the ring of the thiacrown ether molecule was, the larger the selectivity was, and the elution mechanism of the complexes was explained due to the formation of ion-pair when the concentration of sodium dodecyl sulfate (SDS) in mobile phase was lower than 10 mM and due to the formation of micelle when the SDS concentration was higher than 10 mM. As a conclusion, separations of the noble metal-thiacrown ether complexes in an optimum separation condition were accomplished successfully and the method was proved to be an useful one for the separation and determination of Ag (Ⅰ) ion in a black-white photographic fixing solution.

  • PDF

Isolation and Concentration of Organic Components from a Complex Matrix into Three Fractions of Different Volatilities (복합 유기혼합물체로부터 휘발성이 서로 다른 세 유기화합물 그룹의 분리 농축방법의 연구)

  • Kyoung Rae Kim
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.30-37
    • /
    • 1981
  • A simple micro-sampling system is described which facilitates isolation and concentration of complex organic constituents into three fractions of different volatilities. The method involves the headspace trapping of very volatile components from a complex matrix onto a porous polymer, Tenax GC, followed by the solvent elution of the matrix and the subsequent fractions of the eluate into volatile and less-volatile fractions. The headspace and the volatile fractions are then analyzed by high-resolution capillary gas chromatography. The less-volatile fraction is analyzed by high-performance liquid chromatography. Experimental details and the results obtained using tobacco leaves as a complex organic matrix are presented.

  • PDF

High-Performance Liquid Chromatographic Determination of Phenothrin and Silafluofen Residues in Crops with Mass Spectrometric Confirmation (고성능 액체크로마토그래피와 질량분석법을 이용한 농산물 중 Phenothrin 및 Silafuofen의 정밀 잔류분석법 개발)

  • Lee, Young-Deuk;Oh, Jae-Ho;Jang, Sang-Won
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.389-400
    • /
    • 2011
  • A high-performance liquid chromatographic (HPLC) method was developed to determine residues of phenothrin and silafluofen, known as synthetic pyrethroids, in agricultural commodities. Insecticide residues were extracted with acetone from representative samples of four crops which comprised rice, apple, pepper and cabbage. The extract was purified serially by liquid-liquid partition and Florisil column chromatography. For rice and pepper samples, acetonitrile/n-hexane partition was additionally adopted to remove nonpolar interferences. Reversed phase HPLC using an octadecylsilyl column was successfully applied to separate two phenothrin isomers and silafluofen from sample co-extractives. Intact parent compounds were sensitively detected by ultraviolet absorption at 226 nm. Recovery experiment at the quantitation limit validated that the proposed method could apparently determine phenothrin and silafluofen residues at 0.02 and 0.01 mg/kg, respectively. Mean recoveries of phenothrin and silafluofen from four crop samples fortified at three levels in triplicate were in the range of 82.4~109.8% and 83.7~109.8%, respectively. Relative standard deviations of the analytical method were all less than 10%, irrespective of crop types and spiking levels. A selected-ion monitoring (SIM) LC/mass spectrometry (MS) with electrospray ionization was provided to confirm the suspected residue of phenothrin, even though no sufficient ionization of silafluofen was obtained. Both phenothrin and silafluofen could be successfully confirmed by gas chromatography/MS SIM with electron impact at 70 eV. The proposed method is sensitive, repeatable and rapid enough to apply to officially routine inspection of agricultural products.

Simultaneous Analysis of Cold Medicine Component by High-Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 Cold Medicine 성분의 동시 분석)

  • Wonju Lee;Seung-Tae Choi;Keun-Sik Shin;Jin-Young Park;Jae-Ho Sim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.867-873
    • /
    • 2023
  • In this study, for the purpose of standardized quality control of a cold medicine, we simultaneous analyzed four main chemical components of a cold medicine: acetaminophen, caffeine, methyl paraben, and propyl paraben. The sample was subjected to quantitative analysis using high performance liquid chromatography (HPLC), after pretreatment of four components. The experiment was carried out by using Isocratic elution at wavelength of 270nm. Acetonitrile and water (H2O) were used as a mobile phase at a flow rate of 1.0mL/min in a commercial C18 reversed-phase column. A volume of 10uL cold medicine were injected into the column with column oven temperature at 35℃. As a result of the experiment, the values of Resolution were 4.983, 1.596, 5.519, and 1.678 respectively-well over Rs >1.5, which indicates that the separation of four components were efficient. In addition, value of symmetry factor of the components was 1.056, 1.069, 1.032, and 1.133 respectively, to show its symmetrical stability. The calibration curve of all four components exhibits good linearity with R2 >0.9995 to 0.9999. Furthermore, the limit of detection(LOD) were between 0.0118 to 1.5973 mg/mL, while the limit of quantification (LOQ) were between 0.0353 to 4.7919 ㎍/mL with the recovery rate of 79.6% ~ 120.5%. The results of this study showed an efficient quality evaluation of a simultaneous analysis method for cold medicine components.

Analysis of Tertiary Amines and Quaternary Ammonium Salts in Electrolyte Solutions of Electrolytic Capacitors by Ion-Pair Liquid Chromatography (전해커패시터 전해액 중 3차 아민과 4차 암모늄염의 이온쌍 액체크로마토그래피에 의한 분석)

  • Chung, Yongsoon;Chang, Cheolkyu;Lee, Jeongmi;Lee, Younghoon;Kim, Seong Ho
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.231-239
    • /
    • 1997
  • We developed a procedure that can effectively separate and determine tertiary amines and quaternary ammonium salts in some samples with reverse phase ion-pair high performance chromatography, employing indirect spectrophotometric detection method. Detection and ion-pairing reagents used in this study were benzyl trimethylammonium chloride (BTMACl) and sodium dodecyl sulfate(DDSANa), respectively. Eluting the electrolyte solutions of some commercial electrolytic capacitors with a MeOH(40):water(60) eluent (pH 8.5 adjusted with NH4Cl-NH3 buffer) containing 0.010M DDSANa and 0.004 M BTMACl through Supelco LC-18 or ${\mu}$-Bondapak phenyl column, amines and ammonium salts contained in the sample were successfully separated and determined. Varying the composition, especially the content of quaternary ammonium salts, of electrolyte solutions based on this analysis. we could prepare the low impedance(0.08~0.13) electrolytic capacitors with excellent electrical properties and it was a confirmation that the analysis is favorable.

  • PDF

Ion-Pair High Performance Liquid Chromatographic Retention Behavior of Salicylic Acid and Its Derivatives (살리실산 및 그 유도체들의 이온쌍 고성능액체크로마토그래피 머무름 거동)

  • Lee, Kangwoo;Chung, Yongsoon;Oh, Sangkeun
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.203-208
    • /
    • 1999
  • The ion-pair high performance liquid chromatographic elution behavior of salicylic acid and its derivatives was studied with measuring capacity factor, k', changing the concentration of ion-pairing reagent (tetrabutylammonium chloride, TBACl) in mobile phase. As a result, it was found that k' of the samples increase at pH 7.2 as the TBACl concentration increases. The derivatives of salicylic acid were separated each other at an optimum mobile phase condition which was found from the observation of the retention behavior. The optimum mobile phase condition was methanol solution($MeOH:H_2O_2$ 30:70) containing 20 mM TBACl for the determination of salicylic acid and methanol solution($MeOH:H_2O_2$ 20:80) containing 40 mM TBACl for p-aminosalicylic acid at pH 7.2. The method has been applied for the analysis of the contents of salicylic acid derivatives in an aspirin tablet and a tuberculosis curing agent.

  • PDF

Comparison of strip analysis and HPLC analysis for the quantitative analysis of cyanobacterial toxin (남조류 독소 정량을 위한 스트립분석법과 HPLC 분석법의 비교)

  • Pyo, Dongjin;Yim, Miyeon
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.168-174
    • /
    • 2015
  • Cyanobacterial toxins, such as microcystins, which exist in Korean lakes, are strongly toxic in fish, cattle, and humans. This study performs a quantitative analysis of cyanobacterial toxins in water by comparing the strip method and the HPLC method. Because the detection ranges of the strip method and the HPLC method are different, the water samples were diluted. The comparison of the strip method and the HPLC method was made using seven samples that contained different concentrations of microcystin. The quantitative results produced by the strip analysis were significantly aligned with the results of the HPLC analysis. The results of correlation analysis were r = 0.99998 and p = 0.00001.

Sturdy of analysis of Xanthan gum as watersoluble-polymer in cosmetics (화장품 중 수용성 고분자인 Xanthan gum 분석연구)

  • Lee, Yong-Hwa;Yang, Jae-Chan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.664-671
    • /
    • 2013
  • Determination of xanthan gum as watersoluble-polymer in commercial cosmetic samples was carried out by High Perfomance Liquid Chromatography(HPLC). An $C_{18}$ reversed-phase column and the selected ELSD detector was applied. The 25mM ammonium acetate/acetonitrile was used for the mobile phase of gradient conditions. The analysis results of HPLC showed good linearity with correlation coefficient of $r^2=0.9993$ in the rage of $50.3{\sim}604.1{\mu}g/ml$ and detection limit of $12.0{\mu}g/ml$.

Effect of Mobile Phase Additive on Enantiomer Resolution for Chiral Amines on Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography (고성능 액체크로마토그래피의 다당유도체를 기초로 한 키랄 고정상에서 이동상 첨가제가 키랄 아민의 광학분리에 미치는 영향)

  • Paik, Man-Jeong;Yoon, Hye-Ran;Lee, Wonjae
    • KSBB Journal
    • /
    • v.29 no.3
    • /
    • pp.205-209
    • /
    • 2014
  • Chromatographic enantiomer resolution of chiral amines was performed on several covalently immobilized and coated chiral stationary phases (CSPs) based on polysaccharide derivatives under the mobile phase conditions containing base or acid or acid/base additive. The chromatographic parameters including separation factors and capacity factors were greatly influenced by the nature of the mobile phase containing base or acid or salt additive as well as the used CSPs. When 0.05% triethylamine/0.05% trifluoroacetic acid as an additive in the mobile phase was used on all CSPs in this study, the greatest enantiomer resolution was observed except for Chiralpak AD. Also, it was shown that the change of base additive into acid or salt in the mobile phase may directly affect chiral recognition mechanisms between the chiral selectors and analytes occurring during enantiomer separation, resulting in the change of elution orders.

Simultaneous Determination of Tar Color Additives in Cold Syrups by Ion Pair-high Performance Liquid Chromatography (이온쌍-고성능 액체크로마토그래피에 의한 감기약 시럽에서 타르색소 첨가물의 동시분석)

  • Jin, Jing-Yu;Huang, Hu;Lee, Beom-Gyu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.459-465
    • /
    • 2010
  • A simple and efficient analytical method for the simultaneous determination of seven tar color additives was developed using ion pair high performance liquid chromatography. The conditions for HPLC analysis were as follows: column, ${\mu}$-Bondapak C18 (10 ${\mu}m$, 300 ${\times}$ 3.9 mm i.d.); gradient mobile phase, 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrile-methanol (65:25:10) as a mobile for fraction A and 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrilemethanol (40:50:10) as a mobile for fraction B; flow rate, 1.0 mL/ min; detection wavelength, 254/520/620 nm. We could attain to the detection limits as 0.01~0.05 ${\mu}$g/mL (254 nm) and 0.005~0.01 ${\mu}$g/mL (520 nm) for six red tar color additives, and 0.05 ${\mu}$g/mL (254 nm) and 0.002 ${\mu}$g/mL (620 nm) for Fast green FCF. This analytical method was applicable to determine the tar color additives contained in several commercial cold syrups.