• 제목/요약/키워드: 고무발포보온재

검색결과 5건 처리시간 0.021초

고무 발포 배관 보온 단열재의 성능 기준 및 평가 (Performance Standards and Evaluation of Elastomeric Flexible Cellular Insulation)

  • 전현석;최현중;최경석;강재식;이승언;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.614-617
    • /
    • 2009
  • Elastomeric Flexible Cellular Insulation is widely used in construction fields to prevent condensation and frozen pipes, reduce energy, and improve insulation. However, when Elastomeric Flexible Cellular Insulation has been installed in buildings in Korea, there was no standardization, which resulted in heat loss Therefore, insulation design standards need to be developed and from these standards, pipe insulation should be improved to increase its efficiency. This study estimates temperature and surface-emissivity according to the thickness of insulation to evaluate thermal performance.

  • PDF

룸코너 시험을 이용한 배관용 보온재의 난연성능 분석 (Evaluation of the Reaction-to-fire Performance of Pipe Insulation Material using Small Room Test)

  • 임옥근;남동군;장효연
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.1-8
    • /
    • 2019
  • 천장이나 배관에 설치된 보온재의 연소로 인해 화재가 확산되는 사례가 발생함에 따라 수계소화설비의 배관보온재는 난연재료 성능 이상의 것을 사용하고 있다. 배관보온재의 일부분을 시편으로 가공하여 난연성능을 평가하고 있지만 설치환경을 고려한 실규모시험을 통한 평가는 이루어지지 않고 있다. 본 연구에서는 국내에서 널리 사용되고 있는 발포폴리에틸렌폼 및 고무발포보온재를 실규모 시험기준인 ISO 20632에 따라 시험하고 유럽의 난연성능 분류 기준과 비교하였다. 배관보온재 재료별로 상이한 난연성능을 보였으며, 특히 발포폴리에틸렌폼보온재의 경우 시공방법에 따라 화재성장율 및 열방출율이 달라졌다. 화재발생 시 배관보온재로 인한 연소확산을 지연시키기 위해서는 설치하는 대상공간의 특성을 고려한 난연성능 적용이 필요하며, 시공 시 사용하는 접착제와 테이프 등 부자재의 난연성 또한 고려해야 함을 확인할 수 있었다.

고무발포 보온재의 적정두께 (A Suitable Thickness of Flexible Elastometic Foam)

  • 윤관선;이교영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.429-433
    • /
    • 2008
  • Due to the construction technique (or the construction culture) growth in and out of Korea, newly-developed products have been continuously released. Furthermore, all legislation and regulation that the World follows are gradually becoming unified. (e.g. FTA(Free Trade Agreement) with the United States was contracted, and inevitable FTA contraction with EU and China), For this reason, it is considered that Korean fire regulation on building interior materials needs to be reviewed and compared with that of international standard so that it becomes legitimate and reasonable one.

  • PDF

배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석 (Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation)

  • 유우준;박정욱;신연제;박형규;임옥근
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.18-25
    • /
    • 2020
  • 본 연구에서는 보온재의 설치 상태를 고려한 ISO 20632와 NFPA 274 시험 기준에 따른 발열량 산출 결과를 분석하였다. 이를 위해서 보온재 총 6종(은박 발포폴리에틸렌(PE(S)), 무은박 발포폴리에틸렌폼(PE(N)), 고무발포(Rubber), 일본-폴리에틸렌폼(PE(J)), 일본-폴리우레탄폼(PU(J)) 그리고 일본-스티로폼(ST(J)))에 대해서 EN 13501-1과 화재성장곡선에 따른 난연 등급을 구분하였다. 그 결과 PU(J), PE(J) 그리고 PE(N)는 Class E 및 Ultra-fast, NFPA 274 시험기준에 의한 PE(S)는 Class D 및 Fast, ISO 20632에 의한 PE(S)는 Class C 및 Slow, 그리고 Rubber와 ST(J)는 Class B 및 Slow로 나타났다. 하지만, 난연 등급 평가 기준인 최대 발열량에 대한 시간평균 기울기는 시험 방법에 따라서 동일 보온재에 대하여 다르게 나타났으며, 보다 정확한 원인을 분석하기 위한 기초 연구가 필요한 것으로 판단된다.