• Title/Summary/Keyword: 계통연계형

Search Result 890, Processing Time 0.047 seconds

LVRT control of Grid-Connected Wind Turbine Using Sliding-Mode Based Direct Power Control (슬라이딩 모드 기반의 직접전력제어를 이용한 계통연계형 풍력발전 시스템의 LVRT 제어)

  • Jeong, Hae-Gwang;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.396-404
    • /
    • 2011
  • This paper proposes a performance improvement of a grid-connected wind turbine using sliding-mode based direct power control under an unbalanced grid fault. The proposed control method has some advantages for grid connected control. At first, it doesn't need the synchronous phase angle of the grid voltage. It has also fast dynamic characteristics compared with a conventional current controller. In addition, it is suitable for an unbalance compensation control. The effectiveness and robustness of the proposed algorithm are verified by simulations and experiments.

A Discrete-time Sliding Mode Control Scheme to Improve Transients of Grid-connected Inverter under Distorted Grid (왜곡 계통 조건에서 계통연계 인버터의 과도응답을 개선하기 위한 이산시간 슬라이딩 모드)

  • Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.338-339
    • /
    • 2018
  • 최근 분산전원 시스템 개발로 인해 계통연계 인버터의 사용이 증가해 왔다. 계통연계 인버터의 주요한 역할은 계통연계 환경에서의 안정적인 운전과 계통 사고 시 중요 부하에 대한 연속적인 전력을 공급하기 위한 독립운전에 있다. 각 모드 전환시의 출력전압의 변동성과 과도응답 특성을 개선하기 위해 최근 다중 루프 및 간접 전류 제어 방식이 계통연계 인버터에 적용되었다. 하지만 이러한 제어 방식은 캐패시터 전압 및 인버터 전류의 측정이 요구되어 시스템의 비용 및 복잡성을 증가시키게 된다. 본 논문에서는 이산시간 상태공간에서의 전상태 관측기를 설계하여 무순단 절체 동작 시 제어기가 요구하는 변수를 추정하고 이를 궤환신호로 사용하여 시스템의 설계 비용 및 복잡성을 줄인다. 또한 계통연계 시 계통유입 고조파 전류를 억제하기 위해 일반적으로 사용되는 기존 공진형 제어기의 과도 응답을 개선하기 위해 이산시간에서 슬라이딩 모드와 공진제어기가 결합된 새로운 제어기 구조를 제안한다. 제안된 기법의 타당성은 PSIM 시뮬레이션을 통하여 입증된다.

  • PDF

Fault-Tolerant Control of a DC-link Voltage Sensor for Grid-Connected Inverter Systems (계통연계형 인버터에서 직류단 전압 센서의 고장 허용 제어)

  • Kim, Gwang-Seob;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.297-298
    • /
    • 2011
  • 최근 계통연계형 인버터 시스템에서 고 신뢰 운전이 매우 중요한 과제로 대두되고 있다. 특히 인버터의 고장에 관한 많은 연구가 진행되고 있다. 본 논문에서는 계통연계형 인버터에서 직류단 전압 센서의 고장 허용 제어 알고리즘을 제안한다. 직류단 전압의 추정값으로 고장의 발생 시에 허용 제어를 수행한다. 매우 빠른 동특성을 가진 제어기가 요구되는 제안된 알고리즘의 적용을 위해 데드비트 전류제어기를 사용한다. 시뮬레이션을 통해 제안된 알고리즘을 검증한다.

  • PDF

Performance for Single-phase Grid-connected PV PCS under the Distorted Voltage Condition in Distribution System (단상 계통연계형 PV PCS 출력 성능)

  • Lee, K.O.;Yu, B.G.;Yu, G.J.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1055_1056
    • /
    • 2009
  • 본 논문은 신.재생 에너지원 중 태양광을 이용한 소용량의 가정용 및 건물용 태양광 발전 시스템인 단상 계통연계형 인버터의 출력전류 고조파 발생에 대한 연구로서 상용제품에 대한 실험 결과를 제시하고, 이를 모의한 실험을 통하여 단상 계통연계형 인버터의 출력전류 고조파 억제를 위한 연구 근거로 제시한다.

  • PDF

Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System (고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출)

  • 고재석;채영민;강병희;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.199-210
    • /
    • 2003
  • In this paper, the new Islanding detection method is studied for utility interactive photovoltaic system(UIPVS). It describes the brief of UIPV system and the features of islanding phenomenon. The new islanding detection method for improving the detection characteristics, HCIM(Harmonic Current Injection Method), is proposed and analyzed. The impedance curve of AC load is derived from the complex power equation for testing Islanding detection features. The proposed detection method and the derivation of islanding condition we verified by the simulation with ACSL and the laboratorial experiments.

Development of 10kW Grid-Connected Wind Power Generation Inverter (10kW급 풍력발전용 계통연계형 인버터의 개발)

  • Lee, Dong-Yup;Son, Yong-Hoon;Shin, Young-Chan;Park, Chan-Heung;Kim, Young-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.628-630
    • /
    • 2008
  • 국내에서 개발되어 판매되고 있는 풍력발전용 계통연계형 삼상 인버터는 대부분 대용량 인버터이다. 이 인버터의 경우 크기도 크고 설치하기가 어려워서 주로 발전 사업용으로 사용되고, 공장 및 산업현장에 설치하기에는 많은 단점을 가지고 있다. 본 논문에서는 이러한 단점을 해결하고 풍력발전의 보급을 위하여 소 용량 풍력발전용 계통연계형 삼상 인버터 시스템을 개발하였다.

  • PDF

A Study on Operating Characteristics of 3Kw Utility Interaction Photovoltaic Power Generation (주택용 3KW 계통연계형 태양광 발전시스템의 MPPT제어 알고리즘 운전특성 연구)

  • Han, Hoo-Seok;Lee, Young-Jin;Han, Sang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.537-538
    • /
    • 2006
  • 태양광 발전시스템의 성능평가 및 분석을 위하여 실증단지 및 시범사업으로 설치 운영하고 있으며, 주택용 3KW 계통연계형 태양광 발전시스템도 10만호 보급사업의 일환으로 추진 중에 있다. 본 논문에서는 이와 같이 추진 중인 3KW 태양광 발전시스템의 기본구성과 설치된 PV시스템의 각종 구성요소 기기 특히 계통연계형 인버터에 대하여 알아보며, 실증시험을 위하여 설치된 모니터링 시스템에서 수집된 데이터를 토대로 PV시스템의 성능을 위한 운전 특성을 분석하였다.

  • PDF

Robust Direct Adaptive Current Controller for Grid-connection Inverter (계통연계형 인버터의 강인한 직접적응 전류제어 기법에 관한 연구)

  • Kim, Tae-Won;Park, Tae-Joon;Han, Mu-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.510-511
    • /
    • 2010
  • 본 논문은 계통연계형 인버터의 정현파 전류제어를 위한 직접 적응제어 기법을 제안한다. 기존의 계통연계형 인버터 전류제어기에 비해 고조파 성분 제거 능력이 우수하고 소프트웨어적으로 쉽게 구현할 수 있는 장점이 있다. LC필터의 L값의 변동에 의한 제어기 내부의 파라미터가 발산하는 문제를 Resetting기법을 적용하여 보완하였다. 본 논문에서 제안한 정현파 전류 적응제어기의 우수성을 시뮬레이션과 실험을 통해 검증하였다.

  • PDF

PCS Design for Single power stage structured PV PCS using Z-source Inverter (Z-소스 인버터를 이용한 일단구조의 계통연계형 태양광 발전용 PCS 설계)

  • Shin, Hyun-Jin;Park, Joung-Hyoung;Kim, Heung-Geun;Chun, Tae-Won;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.314-316
    • /
    • 2008
  • 계통연계형 태양광 PCS는 주로 전압원 인버터와 전압의 승압을 위한 DC/DC컨버터, 즉 이단구조로 구성된다. Z-소스 인버터는 DC/DC컨버터 없이 전압을 승/감압할 수 있다. 3k급 계통연계형 태양광 PCS에 Z-소스 인버터를 적용하여 일단구조로 설계하였고 PSIM 시뮬레이션과 실험을 통하여 타당성을 검증하였다.

  • PDF

Analysis and Active Damping of LCL filter Resonances of Parallel-Connected Utility Interactive Inverters (병렬 연결된 계통연계형 인버터의 LCL필터 공진현상 분석 및 액티브댐핑)

  • Kim, Minkook;Jung, Sanghyuk;Jung, Sehyung;Choi, Sewan;Kim, Kwangseob
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.423-424
    • /
    • 2013
  • 수 MW이상의 인버터 시스템을 구성하기 위해서는 계통연계형 인버터 다수가 PCC에 연결되어 계통과 연결된다. 이러한 경우 단일 인버터의 공진주파수가 LCL필터 값에 의해 결정되는 반면 각각의 인버터들이 서로 영향을 주고받아 공진주파수가 변화한다. 또한 공진주파수가 상용주파수에 가까워짐에 따라 시스템이 불안정해지고 기존의 액티브 댐핑기법으로 공진성분을 억제할 수 없다. 본 논문에서는 다수의 인버터가 계통연계 시 발생하는 공진 현상을 인버터 모델링을 통해 분석하고, 이러한 시스템에 적합한 액티브 댐핑기법을 제안한다.

  • PDF