• Title/Summary/Keyword: 계수기

Search Result 4,075, Processing Time 0.032 seconds

Effects of Injector Shape on Combustion Performance of a Subscale Gas Generator (축소형 가스발생기 분사기 형상에 따른 연소 특성)

  • Kim, Mun-Ki;Lim, Byoung-Jik;Kang, Dong-Hyuk;Ahn, Kyu-Bok;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.472-474
    • /
    • 2012
  • The hot-firing tests of a subscale gas generator were successfully performed to investigate the effect of injector shape variation on its discharge coefficient. The test results showed that discharge coefficient of liquid oxygen injectors was enhanced significantly. However, the combustion instability of low-frequency fluctuation occurred at low and design pressure conditions.

  • PDF

Study on Flow Discharge Characteristics of Liquid Rocket Coaxial Injectors (액체로켓 동축 분사기의 유량계수에 대한 고찰)

  • Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.49-53
    • /
    • 2009
  • The paper presents the results of the experimental study about flow discharge characteristics of double swirl coaxial injectors for a liquid rocket engine. Flow discharge characteristics of injectors become one of critical design issues for LRE combustion devices. Tap water and liquid oxygen/kerosene were used for ambient and hot firing tests, respectively. A combustion discharge coefficient varies depending on a mixture ratio and a recess ratio, and magnitudes of the variations are different with respect to injector shapes and operating conditions. The variation of a combustion discharge coefficient with a LOx injector is considered to result from flame structure changes due to physical property changes.

  • PDF

Fuzzy Scheduling for the PID Gain Tuning (PID 이득 동조를 위한 퍼지 스케줄링)

  • Shin Wee-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.120-125
    • /
    • 2005
  • In this paper, We propose the fuzzy controller for the gain tuning of PID controller The proposed controller doesn't use the crisp output error and rule tables though with a fuzzy inference process in forward fuzzifier, New Fuzzy PID Controller assigns relations and ranges of two variables of PID gain parameters. These new gain parameters are calculated by the fuzzy inference with max-min ranges of Kp and Kd. The Ki parameter is computed automatically between Kp and Kd parameter Is calculated by Ziegler-Nickels tuning rules. Finally we experimented the propose controller by the hydraulic servo motor control system. We can obtained desired results through the good control characteristics.

The Microwave Dielectric Properties of Sintering Condition of ZST Ceramics for Movile Telecommunication System (이동 통신용 ZST세라믹스의 소결조건에 따른 고주파 유전 특성)

  • Seo, Jung-Chull;Lee, Hee-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.257-260
    • /
    • 2000
  • 소결온도 및 소결시간의 변화가 ZST세라믹의 유전상수 $\varepsilon_{\tau}$, 품질계수 $Q{\cdot}f$ 및 공진주파수의 온도계수 $\tau_f$에 미치는 영향에 대하여 연구하였다. 소결온도를 $1420^{\circ}C$까지 올렸을 때 공진기 섭동방법으로 1.6GHz에서 측정한 품질계수 Q가 가장 높았으나, 소결밀도 및 유전상수는 오히려 감소하였다. 소결시간의 증가에 따른 품질계수 Q는 $1300^{\circ}C{\sim}1380^{\circ}C$ 온도 범위에서는 소폭 상승하였으며, 소결밀도 및 유전상수는 거의 일정하였다. 공진주파수의 온도계수 $\tau_f$는 소결온도 및 소결시간의 변화에는 거의 의존하지 않았다.

  • PDF

Design Hourly Factor Estimation with Vehicle Detection System (차량검지기자료를 이용한 고속도로 설계시간계수 산정 연구)

  • Baek, Seung-Geol;Kim, Beom-Jin;Lee, Jeong-Hui;Son, Yeong-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.79-88
    • /
    • 2007
  • Design Hourly Volume (DHV) is the hourly volume used for designing a section of road. DHV is also used to estimate the expected number of vehicles to pass or traverse the relevant section of road in a future target year. The Design Hour Factor (DHF) is defined as the ratio of DHV to Average Annual Daily Traffic (AADT). In addition to high precision of predicted traffic volume, in order to design a roadway to be the proper scale, applying appropriate DHFs considering traffic flow characteristics and type of area which surrounds the relevant roadway is important. This study categorizes sections of expressway (Suh Hae An Expressway) according to their area type and estimates DHFs utilizing traffic data obtained from a vehicle detection system (VDS). This study shows that DHFs calculated using VDS data are different from those using traffic data acquired from a coverage survey. While AADTs from both data show similar values, peak hour volumes from both data show significant differences especially for recreational areas. DHFs from the coverage survey are quite different from the values provided by the Korean design guide or previous research results and DHFs for urban areas are higher than recreational areas. However, DHFs from VDS shows similar values to previous research results. The result of this study suggests that using VDS for estimating DHFs is more reliable than using a coverage survey.

안정적 시계열의 변이상태에 대한 판별연구-변압기 진동신호에 대한 응용을 중심으로-

  • 이정진;정찬수;송정호
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.3
    • /
    • pp.617-628
    • /
    • 1997
  • 시계열 자료의 변이상태(transition status)에 대한 판별은 여러 분야에서 연구되고 있다. 하지만 변압기의 진동신호와 같이 특정한 시계열모형을 적합시키기 힘든 자료는 변이 상태에 대한 판별이 쉽지 않다. 본 논문에서는 정상적인 변압기에서 발생하는 진동신호에 대하여 각 주기별 최대값, 자기상관계수 및 편자기상관계수 등의 경험적 표본분포를 연구한 후, 이를 이용한 관리도를 만들어 변압기 진동신호의 변이상태에 대한 판별을 하였다. 이 방법은 품질관리의 관리도 이론을 시계열자료에 응용한 것으로 비정상적인 변압기 진동신호의 판별에 만족스러운 결과를 가져왔다.

  • PDF

Numerical analysis according to evaporator type (증발기 형태에 따른 수치적 해석)

  • Kim, Dae Yeong;Kim, Moon Ki;Yun, Hong Sun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.103-103
    • /
    • 2017
  • 증발기의 형태에 따라 수치적 해석을 진행하면서 최적의 효율을 나타낼 수 있는 증발기를 설계하는 것이 중요하다. 증발기의 수치적 해석은 EES 프로그램을 이용하여 진행되었으며, 계산의 검증은 자사의 제품의 성능과 비교하면서 검증하였다. 증발기의 수치적 해석의 구성은 지배방정식과 연속방정식을 이용하여, 냉매의 총괄열전달계수, 관내외벽의 열전도율, 공기의 총괄열전달계수를 이용하여 총괄열전달계수를 계산하였으며, 총괄열전달계수를 이용하여 증발기의 열량을 계산하였다. 증발기의 수치적 해석과 자사 제품 5개의 제품과 비교하였고, 평균적으로 약 10%의 오차율을 보였다. 신뢰성이 확보된 계산식을 이용하여 Fin의 간격, 단위 질량유량, 열 교환 코일 길이, 풍량의 조건을 각각 변동시켜 증발기 열량 비교를 하며 경향성을 고찰하였다. Fin의 간격을 1mm에서 20mm으로 0.5mm 간격으로 변화 시켰을 경우, 핀 간격이 좁으면 공기 유속이 빨라져 열 교환 효율이 낮아지며, 반대로 넓어지면 냉매 유량에 비해 공기 유량이 많기 때문에 열 교환 효율이 낮아진다. 열 교환 코일 길이를 500mm에서 2400mm으로 50mm 간격으로 변화 시켰을 경우, 열 교환 코일 길이가 길어질수록 배관의 마찰력과 냉매의 온도 상승으로 인하여 공기 온도와의 온도 차이가 줄어들어 열 교환 효율은 낮아진다. 풍량을 20cmm에서 400cmm으로 10cmm 간격으로 변화 시켰을 경우, 일정 풍량 이상 올라가면 공기 유속이 빨라져서 열량이 낮아지는 경향을 보인다. 질량유량을 3g/sec에서 174g/sec으로 4.5g/sec 간격으로 변화 시켰을 경우, 질량 유량에 따라 비례적으로 열량이 높아지는 경향을 보이다가 일정 질량 유량 이상에서는 공기 풍량에 비해 냉매 유량이 많기 때문에 반비례적으로 열량이 낮아진다. 이처럼 증발기의 설계는 Fin 간격, 열 교환 코일 길이, 풍량, 질량유량 등을 복합적으로 고려하여 증발기 설계를 해야 하며, 저장고의 크기, 부하, 사용목적에 따라 최적화된 증발기를 설계하여야 한다.

  • PDF

Study on the Spray Characteristics of Liquid/Liquid Pintle Injector by Opening Distance (액체/액체 핀틀 분사기의 개도에 따른 분무특성 연구)

  • Yoon, Wonjae;Ahn, Jonghyeon;Ahn, Kyubok;Yoon, Hosung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.14-25
    • /
    • 2021
  • An experimental study was conducted on the spray characteristics of the pintle injector by opening distance. The discharge coefficient of the pintle injector was investigated and the spray angle was measured by taking the spray image by test conditions. As a result of the measurement of the discharge coefficient, it was confirmed that the change in the discharge coefficient of the outer injector was not significant over the experimental conditions, but the change in the discharge coefficient of the inner injector was decreased as the flow rate increased. Measurement of the spray angle showed that the change in the spray angle was not significant in the conditions under which the spray was fully developed, but the spray was not fully developed at low flow rates. This confirmed the possibility of thrust control using the pintle injector.