• Title/Summary/Keyword: 계수가진계

Search Result 73, Processing Time 0.024 seconds

Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet (FRP로 보강한 비보강 조적 벽체의 전단강도 산정)

  • Bae, Baek-Il;Yun, Hyo-Jin;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.305-313
    • /
    • 2012
  • Unreinforced masonry buildings represent a significant portion of the existing and historical buildings around the world. Recent earthquakes have shown the need for seismic retrofitting for these types of buildings. Various types of retrofitting materials (i.e., shotcrete, ECC and Fiber Reinforced Polymer sheets (FRPs)) for unreinforced masonry buildings (URM) have been developed. Engineers prefer to use FRPs, because these materials enhance the shear strength of the wall without expansion of wall sectional area and adding weight to the total structure. However, the complexity of the mechanical behavior of the masonry wall and the lack of experimental data from walls retrofitted by FRPs may cause problems for engineers to determine an appropriate retrofitting level. This paper investigate in-plane behavior of URM and retrofitted masonry walls using two different types of FRP materials to determine and provide information for the retrofitting effect of FRPs on masonry shear walls. Specimens were designed to idealize the wall of a low-rise apartment which was built in 1970s in Korea with no seismic reinforcements with an aspect ratio of 1. Retrofitting materials were carbon FRP and Hybrid sheets which have different elastic modulus and ultimate strain capacities. Consequently, this study evaluated the structural capacity of masonry shear walls and the retrofitting effect of an FRP sheet for in-plane behavior. Also, the results were compared to the results obtained from the evaluation method for a reinforced concrete beam retrofitted with FRPs.

Adsorption Characteristics of Reactive Red 120 by Coal-based Granular Activated Carbon : Isotherm, Kinetic and Thermodynamic Parameters (석탄계 입상활성탄에 의한 Reactive Red 120의 흡착 특성 : 등온선, 동력학 및 열역학 파라미터)

  • Lee, Jong Jib
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.164-171
    • /
    • 2020
  • Adsorption characteristics of reactive red 120 (RR 120) dye by a coal-based granular activated carbon (CGAC) from an aqueous solution were investigated using the amount of activated carbon, pH, initial concentration, contact time and temperature as adsorption variables. Isotherm equilibrium relationship showed that Langmuir's equation fits better than that of Freundlich's equation. The adsorption mechanism was considered to be superior to the adsorption of monolayer with uniform energy distribution. From the evaluated Langmuir separation coefficients (RL = 0.181~0.644), it was found that this adsorption process belongs to an effective treatment area (RL = 0~1). The adsorption energy determined by Temkin's equation and Dubinin-Radushkevich's equation was E = 15.31~7.12 J/mol and B = 0.223~0.365 kJ/mol, respectively. The adsorption process showed the physical adsorption (E < 20 J/mol and B < 8 kJ/mol). The adsorption kinetics followed the pseudo first order model. The adsorption reaction of RR 120 dye on CGAC was found to increase spontaneously with increasing the temperature because the free energy change decreased with increasing the temperature. The enthalpy change (12.747 kJ/mol) indicated an endothermic reaction. The isosteric heat of adsorption (△Hx = 9.78~24.21 kJ/mol) for the adsorption reaction of RR 120 by CGAC was revealed to be the physical adsorption (△Hx < 80 kJ/mol).

Normal blood pressure values and percentile curves measured by oscillometric method in children under 6 years of age (진동식 자동 혈압계로 측정한 6세 이하 아동의 정상 혈압치와 백분위수 곡선)

  • Sohn, Jin A;Lee, Hee Sook;Lim, Kyoung Aha;Yoon, So Young;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Lee, Soon Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.998-1006
    • /
    • 2008
  • Purpose : Hypertension is defined as average systolic blood pressure and/or diastolic blood pressure that is ${\geq}95^{th}$ percentile for gender, age, and height on ${\geq}three$ occasions. Knowing that blood pressure values increase in children as they grow older, the purposes of this study were to measure blood pressure by an oscillometric device and to determine normal values and percentile curves for children. Methods : Systolic and diastolic blood pressures were measured twice with an oscillometric device in 3,545 boys and 3,145 girls under six years of age, in Seoul. Using this data, we determined average blood pressure values and percentile curves based on gender and age; we subdivided these values into blood pressures of $50^{th}$, $90^{th}$, $95^{th}$, and $99^{th}$ percentiles, by percentile of height. The regression coefficients and standard deviations of the systolic and diastolic blood pressure values were obtained from linear regression models. Results : Older boys and girls had higher systolic and diastolic blood pressure values. Older boys and girls in the same percentile of height for age had higher systolic and diastolic blood pressure values. Taller boys and girls within the same age group had higher systolic and diastolic blood pressure values. Conclusion : Blood pressure standards based on gender, age, and height were obtained via an oscillometric method. Llimitation of this study is that the study population was not from the whole country, but exclusively from Seoul. Nonetheless, the data from this study will be helpful in diagnosing and managing hypertension in Korean children.

강원지역 보건진료원에 관한 업무 분석 연구

  • Jo, Won-Jeong;Lee, Gyeong-Ja
    • Research in Community and Public Health Nursing
    • /
    • v.1 no.1
    • /
    • pp.172-173
    • /
    • 1989
  • 본 연구는 전국의 보건진료원이 하는 업무를 분석하여 우리나라 보건진료원 제도 정착에 도움을 주는 기초자료를 제공하는 연구의 일환으로 강원도 지역에서 실시하였다. 연구대상은 강원도에 있는 보건진료원 전수로 하였고 이중 응답자수는 108명이었다. 연구도구는 문헌과 간호교육자들에 의해 작성 된 구조화된 설문지를 사용하였으며 수집된 자료는 SPSS를 이용하여 빈도, 백분율, 평균 및 피어슨 상관계수를 구하였고 유의성 검정을 위해서 t-test, ANOVA의 통계방법을 사용하였다. 본 연구결과를 통하여 얻은 결론은 다음과 같다. 1) 조사대상자인 보건진료원의 평균 연령이 31.5세이며 과반수의 보건진료원이 30세 미만 이었고 기혼자가 마혼자보다 약간 많았다. 보건진료원의 반수 이상이 현재 가족과 동거하고 있었고 학력은 3년제 간호전문대학 졸업자가, 경력은 3년 미만인 사람이 대부분이었으며 종교를 가진 사람이 대부분 이었으며 종교를 가진 사람이 안가진 사람보다 더 많았다. 또한 보건진료원의 근무지역 조건은 대부분이 을지에서 근무하고 있었고 대부분의 보건진료원이 신축된 보건진료소 시설에서 업무를 수행하고 보건진료소 내의 숙소에서 거주하는 것으로 냐타났다. 2) 보건진료원이 담당하는 평균 주민수는 1,660.8명 이었으며 과반수 정도의 보건진료원이 $501\sim1,000$명이 이상적인 적정 담당 주민수라고 생각하고 있었다. 강원도 주민의 연평균 보건진료소 이용자수는 4,099.3명 이었고 이용 주민수가 5,000명 이상인 보건진료소도 11개소 12.9 %나 되었다. 3) 보건진료소 사업대상지역 내에 있는 보건 의료기관은 약방 및 약종상이 62.1 %로 가장 많이 분포되어 있었고 보건지소도 16 %나 사업대상지역 내에 함께 있는 것으로 나타났다. 지역주민의 보건의료기관 이용은 보건진료소가 59.0 % 로 지역주민이 가장 많이 이용하고 있었고 보건 진료원이 가장 많이 이용하는 의뢰기관은 뱅 의원이 66 %, 보건소가 36.4 %로 나타났다. 또한 보건진료소의 보건의료기관과의 협조관계는 보건소와는 과반수 정도가 잘 협조하고 있다고 응답 한 반면 보건지소와 잘 협조하고 있다고 응답한 율은 37.6 % 밖에 안되었다. 4) 보건진료원이 업무영역 수행 정도를 살펴 보면 5점 만점에 통상질환관리가 3.69점, 사업 운영 관리 및 지도는 3.45점, 모자보건 및 가족계획은 3.28 점, 지역사회 조직 및 개발은 3.27 점, 보건정보체계 개발 및 수집은 3.17 점, 사업 계획 수립은 3.14 점, 지역사회 보건관리는 3.13 점의 순으로 나타났다. 보건진료원의 업무영역을 l 일 8 시간으로 하여 l 주 44 시간을 기준으로 측정하면 통상질환관리 18.56시간, 지역사회 보건관리 5.67 시간, 모자보건 및 가족계획 5.52 시간, 사업 운영관리 및 지도 4.10시간, 지역사회 조직 및 개발 3.05 시간, 보건정보체계 개발 및 수집 2.94 시간, 사업계획 수립 2.89시간의 순으로 나타났다. 5) 보건진료원의 업무영역별 수행 소요시간의 상판판계를 살펴보면 지역사펴 조직 및 개발을 위 해 소요한 시간은 사엽계획 수립 소요시간 및 보건정 보체계 관리 소요시간과 순상관관계를, 사업 계획 수립 소요시간은 지역사회 보건관리, 모자보건 및 가족계획 관리 소요시간 및 보건정보체제 관리 소요시간과 순상관관계를 나타냈다. 또한 통상질환관리 소요시간은 지역 사회 조직 및 개발, 사업계획 수립, 지역사회 보건관리와 모자보건 및 가족계획 관리, 사업운영 관리 및 지도, 보건정보체계 관리 소요시간과 역상관관계를 나타내었다. 6) 보건진료원의 총 업무수행 정도를 잘펴보면 업무수행 점수의 평균은 87.5점이었으며 보건진료원의 근무지가 병지이고 보건진료소의 시설상태가 나쁜 경우 업무수행 점수가 높은 것으로 나타났으며 업무수행 정도와는 별 차이가 없었다.

  • PDF

Isolation of marine algicidal bacteria from surface seawater and sediment samples associated with harmful algal blooms in Korea (유해조류번성 주변의 해수와 침전물에서 살조균의 분리)

  • Kristyanto, Sylvia;Kim, Jaisoo
    • Korean Journal of Microbiology
    • /
    • v.52 no.1
    • /
    • pp.40-48
    • /
    • 2016
  • This study mainly focused on isolation of marine algicidal bacteria associated with phytoplankton blooms and characterization of algicidal activity against harmful algae. Harmful algal blooms (HABs) found naturally in surface waters have caused many environmental problems worldwide. In this study, forty bacterial strains that have capability of inhibiting harmful algal growth were isolated from Masan Bay, Jinhae Bay, Dol Island, Jangmok Bay, and the Tongyeong Sea, Republic of Korea. The bacteria were screened furthermore for the characteristics on algicidal activities against Cochlodinium polykrikoides, Chattonella marina, Skeletonema costatum, Heterosigma akashiwo, Heterocapsa triquetra, Prorocentrum minimum, and Scrippsiella trochoidea. As a result, the algicidal bacteria that were screened from double over layer agar and microscopic counts tests belonged to genera Pseudomonas, Vibrio, Bacillus, Pseudoalteromonas, Ruegeria, Joostella, Marinomonas, Stakelama, Porphyrobacter, and Albirhodobacter. One of the most important HAB species is Co. polykrikoides and the strongest algicidal activity against the dinoflagellate was 94.00% after 6 h treatment with 10% bacterial culture filtrate. In this study, Marinomonas sp. M Jin 1-8, Stakelama sp. ZB Yeonmyeong 1-11 & 1-13, Porphyrobacter sp. M Yeonmyeong 2-22, and Albirhodobacter sp. 6-R Jin 6-1 were found to be as new genera of bacteria having anti-algal activity. These results suggest that these bacteria might play an important role in controlling phytoplankton blooms.

Comparison of Misalignment and Retardation Errors of Dual Rotating Quarter-Wave Plates in Muller-Matrix Ellipsometry (타원편광 분석기에서 정렬오차와 사분파장판의 지연오차로 인한 뮬러 매트릭스 오차 분석)

  • Cheong, Hai Du;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.262-272
    • /
    • 2014
  • Using an ellipsometer with dual rotating quarter-wave plates, we have analyzed the relationship between Fourier coefficients and Mueller matrices in the cases of an error-free optical system and of five systematic errors (alignment errors and retardation errors in the quarter-wave plates, and alignment error in the analyzer). In the case with five systematic errors, simulation results show that retardation errors cause more error in the diagonal elements of the Mueller matrix than do alignment errors. We have found that errors in the Mueller matrix caused by initial misalignment of the dual quarter-wave plates were the same. We have chosen the rotation rates of two quarter-wave plates such that the rotational frequencies ${\omega}_1$ and ${\omega}_2$ differ by a factor of 5, i.e. ${\omega}_2=5{\omega}_1$. The simulation results show 0.18% relative error in the diagonal elements ($m_{22}$ and $m_{33}$) and 200% relative error in the off-diagonal elements ($m_{23}$ and $m_{32}$), when we compare errors caused by misalignment of the analyzer to those caused by initial misalignment of the quarter-wave plates. We can use these results in measuring accurate Mueller matrices of optical materials.

Extraction of Water Depth in Coastal Area Using EO-1 Hyperion Imagery (EO-1 Hyperion 영상을 이용한 연안해역의 수심 추출)

  • Seo, Dong-Ju;Kim, Jin-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.716-723
    • /
    • 2008
  • With rapid development of science and technology and recent widening of mankind's range of activities, development of coastal waters and the environment have emerged as global issues. In relation to this, to allow more extensive analyses, the use of satellite images has been on the increase. This study aims at utilizing hyperspectral satellite images in determining the depth of coastal waters more efficiently. For this purpose, a partial image of the research subject was first extracted from an EO-1 Hyperion satellite image, and atmospheric and geometric corrections were made. Minimum noise fraction (MNF) transformation was then performed to compress the bands, and the band most suitable for analyzing the characteristics of the water body was selected. Within the chosen band, the diffuse attenuation coefficient Kd was determined. By deciding the end-member of pixels with pure spectral properties and conducting mapping based on the linear spectral unmixing method, the depth of water at the coastal area in question was ultimately determined. The research findings showed the calculated depth of water differed by an average of 1.2 m from that given on the digital sea map; the errors grew larger when the water to be measured was deeper. If accuracy in atmospheric correction, end-member determination, and Kd calculation is enhanced in the future, it will likely be possible to determine water depths more economically and efficiently.

Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor (나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과)

  • Cho, Yong-Jin;Kim, Chul-Jin;Kim, Namsoo;Kim, Chong-Tai;Kim, Tae-Eun;Kim, Hyo-Sop;Kim, Jae-Ho
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • Surface plasmon resonance (SPR) which is utilized in thin film refractometry-based sensors has been concerned on measurement of physical, chemical and biological quantities because of its high sensitivity and label-free feature. In this paper, an application of SPR to detection of alcohol content in wine and liquor was investigated. The result showed that SPR sensor had high potential to evaluate alcohol content. Nevertheless, food industry may need SPR sensor with higher sensitivity. Herein, we introduced a nano-technique into fabrication of SPR chip to enhance SPR sensitivity. Using Langmuir-Blodgett (LB) method, gold film with nano-structured surface was devised. In order to make a new SPR chip, firstly, a single layer of nano-scaled silica particles adhered to plain surface of gold film. Thereafter, gold was deposited on the template by an e-beam evaporator. Finally, the nano-structured surface with basin-like shape was obtained after removing the silica particles by sonication. In this study, two types of silica particles, or 130 nm and 300 nm, were used as template beads and sensitivity of the new SPR chip was tested with ethanol solution, respectively. Applying the new developed SPR sensor to a model food of alcoholic beverage, the sensitivity showed improvement of 95% over the conventional one.

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.

The study of quantitative analytical method for pH and moisture of Hanji record paper using non-destructive FT-NIR spectroscopy (비파괴 분석 방법인 푸리에 변환 근적외선 분광 분석을 이용한 한지 기록물의 산성도 및 함수율 정량 분석 연구)

  • Shin, Yong-Min;Park, Soung-Be;Lee, Chang-Yong;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • It is essential to evaluate the quality of Hanji record paper without damaging the record paper by previous destructive methods. The samples were Hanji record paper produced in the 1900s. Near-infrared (NIR) spectrometer was used as a non destructive method for evaluating the quality of record papers. Fourier transform (FT) spectrometer was used with 12,500 to 4,000 $cm^{-1}$ wavenumber range for quantitative analysis and it has high accuracy and good signal-to-noise ratio. The acidity and moisture content of Hanji record paper were measured by integrating sphere as diffuse reflectance type. The acidity (pH) of chemical factors as a quality evaluated factor of Hanji was correlated to NIR spectrum. The NIR spectrum was pretreated to obtain the coefficients of optimum correlation. Multiplicative scatter correction (MSC) and First derivative of Savitzky-Golay were used as pretreated methods. The coefficients of optimum correlation were calculated by PLSR (partial least square regression). The correlation coefficients ($R^2$) of acidity had 0.92 on NIR spectra without pretreatment. Also the standard error of prediction (SEP) of pH was 0.24. And then the NIR spectra with pretreatment would have better correlation coefficient ($R^2$ = 0.98) and 0.19 as SEP on pH. For moisture contents, the linearity correlation without pretreatment was higher than the case with pretreatment (MSC, $1^{st}$ derivative). As the best result, the $R^2$ was 0.99 and SEP was 0.45. This indicates that it is highly proper to evaluate the quality of Hanji record papers speedily with integrated sphere and FT NIR analyzer as a non-destructive method.