• Title/Summary/Keyword: 경 엑스선

Search Result 25, Processing Time 0.022 seconds

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

Acquisition of Monochromatic X-ray Using Multilayer Mirror (다층박막 거울을 이용한 단색 엑스선 획득)

  • Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • A hard X-ray microscope system for obtaining images of nano-spatial resolution has been widely studied and requires monochromatic X-ray. A multilayer mirror of 84% reflectivity was designed to acquire tungsten characteristic X-ray of 8.4 keV from the white beam generated from an X-ray tube, and the C/W multilayer mirror of $50{\times}50\;mm$ size and 5.65 nm d-spacing was fabricated by the ion-beam sputtering system. The C/W multilayer had a uniformity of 99.5%, and the structure of the multilayer mirror was verified by a TEM image. The obtainable x-ray reflectivity for the C/W multilayer mirror at 8.4 keV was estimated from measuring the X-ray reflectivity using the copper characteristic X-ray of 8.05 keV. Monochromatic X-ray of 8.4 keV was generated by combining a X-ray tube, and the reflectivity and monochromaticity were 77.1% and 0.21 keV, respectively. Monochromatic X-ray generated from the combination of an X-ray tube and an C/W multilayer mirror has enough potential to use X-ray source for hard X-ray microscope system of laboratory size. If the C/W multilayer mirror of d-spacing of a few nanometers can be fabricated, monochromatic X-ray corresponded to 17.5 keV, molybdenum characteristic X-ray, can be obtained and applied to mammography in the medical application.

A Study of the 3D Anatomical Structure Analysis of Leech Using Hard X-ray Micro Tomography by Synchrotron Radiation (방사광 경 엑스선 마이크로 단층촬영을 이용한 거머리의 해부학적 3차원 구조분석)

  • Lee, Ji Won;Lee, On Seok
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.70-77
    • /
    • 2016
  • In this study, we aim to obtain the fundamental data needed for the objective analysis and bio-mimetics of leeches, using x-ray imaging with radiation that allows 3D analysis of the detailed anatomic structures of leeches. It was confirmed that through using radiation, detailed images of leeches can be obtained, allowing 3D analysis of leeches' anatomical structures. Also, since the data obtained through the radiation allows you to observe the micro-structure, it can serve as a good resource for component analysis, as well as physiological and functional research. More, it is hoped to contribute to further research in the areas of bio-mimetics using leeches.

Design and Fabrication of Hard X-ray Zone Plate (경 엑스선 존 플레이트(Zone Plate) 설계 및 제작)

  • Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.27-31
    • /
    • 2010
  • Spatial resolution is determined by the performance of x-ray optics used in the x-ray imaging system. A zone plate was designed for obtaining a high spatial resolution image at x-ray energy of 8.5keV. A spatial resolution of 80 nm was estimated by the ray tracing when an x-ray tube of tungsten targe was used instead of synchrotron radiation. The designed zone plate of outermost zone width of 40nm was successfully fabricated by the electron-beam lithography.

A Case of Atypical Pathogen Pneumonia, associated with Recurrent into Diffuse Pneumonic Consolidation (재발성 경과를 취한 비정형 병원균주 폐렴 환자 1예)

  • Oh, Jong-Kap
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.391-400
    • /
    • 2011
  • Pneumonia is an infection of the lungs and respiratory system and can be classified by a variety of factors such as infectious agents, etiology, infection area, and other criteria. From a 46-year-old male, who was suspected of being infected with atypical pathogen pneumonia and underwent such tests as serological testing, examination of sputum, urine examination, parasite examination, bronchoscopy, needle biopsy and so on, no significant abnormality was found. This patient also showed no specific symptoms like auscultatory abnormalities, high fever, nonproductive cough, muscle stiffness, sputum production, dyspnea. Prescription of broad-spectrum oral antibiotics and ant-parasitic didn't seem to be effective against bacterial and atypical pathogen. The patient's condition alternately repeated between natural cure and recurrence. The average healing process during which scarring, nodule recurrence and disappearance on the lungs happened was about 20 days. Chest radiography and chest high resolution computerized tomographic scans(HRCT scan) was performed to depict parenchymal aberrations and demarcate the extent and distribution of atypical pathogen pneumonia. As a result, chest radiography did not show the specific symptoms, whereas areas of opacity (seen as white) which represent consolidation were revealed in chest HRCT scan. This indicates that only chest radiography is not that useful for early diagnosis of atypical pathogen pneumonia in patients, since it can't show exactly what the symptom is because of the barriers such as diaphragm, liver, and spine. Therefore, it is desirable that chest HRCT should be used in the diagnosis to compare with the results of chest radiography. Here, report with literature investigations the case of recurrent atypical pathogen pneumonia.

Different Expressions of HIF-$1\alpha$, Bcl-2 and Baxin DU145 Prostate Cancer Cells Transplanted in Nude Mouse between X-Ray and Neutron Irradiation (누드마우스에 주입된 DU-145 전립샘암에서 엑스선과 중성자선에 의한 HIF-$1\alpha$, Bcl-2, Bax 발현의 차이)

  • Kong, Moon-Kyoo;Kang, Jin-Oh;Kim, Sang-Ki;Shin, Dong-Oh;Park, Seo-Hyun;Kim, Chang-Ju;Chang, Hyun-Kyung
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.218-227
    • /
    • 2009
  • Purpose: To investigate the radiobiologic effects of neutron and X-ray irradiation on DU-145 prostate carcinoma cells by identifying the differences of HIF-$1\alpha$ expression and apoptosis. Materials and Methods: Nude mice were injected with the human prostate cancer cell line, DU-145, and then irradiated with 2 Gy and 10 Gy X-rays, or 0.6 Gy and 3.3 Gy neutrons, respectively. The mice were sacrificed at 24 hours and 120 hours after irradiation. The expression levels of HIF-$1\alpha$, Bcl-2 and Bax were compared with immunohistochemical staining and western blotting. The apoptotic indexes were compared with the Terminal deoxynucleotidyl biotin-dUTP nick and labeling (TUNEL) assay. Results: At day 1, HIF-$1\alpha$ and Bcl-2 expression decreased, while Bax expression and the number of TUNEL positive cells increased in neutron irradiated groups for the control and X-ray irradiated groups. The Bcl-2/Bax ratio was significantly lower in the neutron irradiated groups regardless of dose (p=0.001). The same pattern of the differences in the expressions of the HIF-$1\alpha$, Bcl-2, Bax, Bcl-2/Bax ratio, and apoptotic indexes were indentified at day 5. HIF-$1\alpha$ expression was related with Bcl-2 (p=0.031), Bax (p=0.037) expressions and the apoptotic indexes (p=0.016) at day 5. Conclusion: Neutron irradiation showed a decrease in HIF-$1\alpha$, Bcl-2 expression, and Bcl-2/Bax ratio, but increased Bax expression regardless of dose. This study suggests that the differences radiobiological responses between photon and neutron irradiation may be related to different HIF-$1\alpha$ expression and subsequent apoptotic protein expressions.

Ultrasonographic Measurement of Articular Cartilage Thickness of Medial Femoral Condyle in Knee Osteoarthritis (슬관절 골관절염에서 초음파를 이용한 대퇴 내과 관절 연골의 두께 측정)

  • Kim, Jung-Man;Kim, Tae-Hyung;Im, Dong-Sun;Kang, Min-Gu;Lee, Kyu-Jo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the correlation between the medial joint space on weight bearing simple X-ray and the ultrasonographic articular cartilage thickness. Materials and Methods: The articular cartilage thickness of 91 osteoarthritic knees of 73 patients were measured with weight bearing simple X-ray and ultrasonography between June 2010 and September 2010. Male were 13 and female were 60. Right knees were 35, left knees were 20 and bilateral involvements were 18. Medial joint spaces on X-ray were measured in full extension view and $45^{\circ}$ PA(Rosenberg) view. Femoral cartilage thicknesses at and those at the point between the middle 1/3 and posterior 1/3 area were measured by ultrasonography, that were scanned coronally at $30^{\circ}$ flexion and $130^{\circ}$ flexion respectively. The results were analyzed statistically by Pearson correlation test and Bland-Altman plot test. Results: Medial joint spaces measured in full extension view and femoral articular cartilage thicknesses at the point between the anterior 1/3 and middle 1/3 area measured with sonography were statistically correlated and medial joint spaces measured in $45^{\circ}$ PA view and those at the point between the middle 1/3 and posterior 1/3 area measured with sonography were also correlated (P<0.05, $SD{\pm}2$). Conclusion: The measurement of articular cartilage thicknesses by the ultrasonography was easy even in the patient who are unable to take weight bearing view and was thought to be a useful diagnostic and follow up method to examine the degenerative change in addition to simple radiographic examination in the knee osteoarthritis.

  • PDF