Pinhole Bone Scintigraphic Manifestation of Fibrous Dysplasia (섬유성 이형성증의 바늘구멍 골스캔 소견)

  • Baek, Jee-Hee;Lee, Sung-Yong;Kim, Sung-Hoon;Chung, Yong-An;Kim, Bum-Soo;Song, Ha-Hun;Chung, Soo-Kyo;Kang, Si-Won;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.452-458
    • /
    • 1997
  • To evaluate the pinhole scintigraphic findings and its significance, authors retrospectively compared the pinhole bone scintigrams and corresponding radiograms of 16 lesions in 14 patients with fibrous dysplasia. They were diagnosed pathologically in 10 lesions and radiologically in 6 lesions. The mean age of patients was 41.1 years. The mean interval between two studies was 1.1 days. Locations were ribs 7, pelvic bone 4, clavicle 1, long bones 4(femur 2, tibia 1, humerus 1). The radiographic findings were as follows : the central portions were radiolucent(n=9), ground-glass opacities(n=5) or sclerotic(n=2) and the peripheral appearance were sclerotic rim(n=5), septation(n=7), cortical perforation (n=10) and invisible cortical thinning(n=9). Pinhole scintigraphic findings were as follows; Central portions showed normal 1+ uptake in 6 cases(radiolucent 5, ground-glass opacity 1), slightly increased 2+ upta- ke in 7 cases(radiolucent 4, ground-glass opacity 3), and marked 3+ uptake in 3 cases(ground-glass opacity 1, sclerotic 2). The 15 of 16 lesions showed more intense uptake in the peripheral portion: slightly increased 2+ uptake corresponding to the sclerotic rim(5/5) and unvisible cortical thinning(1/9), and irregular foci of marked 3 + uptake corresponding to septation(7/7), cortical perforation(10/10) and invisible cortical thinning (8/9). One of 16 lesions showed homogeneous 2+ uptake. In conclusion, pinhole scintigram provides information on regional activity of the fibrous dysplasia, which would be helpful in diagnosis, prediction of prognosis and determination of treatment plan.

  • PDF

Outcome of Patch Angioplasty for Left Main Coronary Ostial Stenosis (좌주관상동맥 개구부 협착에서의 혈관성형술의 결과)

  • Kang, Chang-Hyun;Na, Chan-Young;Seo, Hong-Joo;Kim, Jae-Hyun;Lee, Cheul;Chang, Yoon-Hee;Hwang, Seong-Wook;Baek, Man-Jong;Oh, Sam-Se;Kim, Woong-Han;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.56-63
    • /
    • 2004
  • Background: Patch angioplasty is an alternative surgical procedure to coronary artery bypass grafting (CABG) for left main coronary ostial stenosis. The purpose of this study is to evaluate the outcome of patch angioplasty by analyzing the short-term and long-term results. Material and Method: Twenty nine patients who had undergone patch angioplasty due to left main coronary ostial stenosis between July 1991 and May 2003 were enrolled in the study. The mean age of the patients was 53.1 $\pm$12.5 years. There were 8 males and 21 females, and there were 12 female patients who had no risk factor for atherosclerosis. Twenty six (89.7%) patients showed isolated coronary ostial stenosis without any distal coronary lesion. Result: Anterior approach was used in 28 patients and superior approach was used in one patient. Transsection of the main pulmonary artery was used in one patient. Concomitant CABG was performed in 4 patients because of left anterior descending artery lesions in 3 patients and unstable postoperative hemodynamic status in one patient. Hospital mortality had occurred in one patient (3.4%) and late mortality also in one patient, therefore the overall 5 year survival rate was 91.2$\pm$6.1%. Seventeen coronary angiographies were done in 13 patients (44.8%) postoperatively. Two distal patch stenoses, 1 proximal patch stenosis, and 1 new right coronary ostial lesion were identified and 3 percutaneous interventions and 1 CABG were performed during the follow-up period. The overall 5 year freedom from reintervention rate was 82.4 $\pm$ 8.5%. Aortic regurgitation less than grade 1 had developed postoperatively in 4 patients and one patient showed progression of preexisting aortic regurgitation from grade II to III. Conclusion: Patch angioplasty in left main coronary ostial lesion showed acceptable short-term and long-term results in this study. However, restenosis at the patch anastomosis site and aortic regurgitation should be carefully investigated during the follow-up period.

Dynamic Characteristics of Actuator for High Density Optical Recording Pick-up (고밀도 기록용 광픽업의 ACTUATOR 동특성)

  • 임경화;이용훈;김석중;이재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.258-263
    • /
    • 1995
  • 미래 정보와 시대에서 중추적인 역할을 할 광관련 멀티미디어 장비들은 최근 관련 산업계에서 주목을 받기 시작하고 있고 특히 기존 VTR(Video Tape Recorder) 시장을 대체할 차세대 DVDR(Digital Video Disk Recorder)는 기술전쟁이라고 할 정도로 선진 기업의 연구가 치열해지고 있다. DVDR 시스템에서는 필요한 정보들을 레이저빔을 이용한 광학신호로 바꾸어 광디스크에 기록, 재생하는 광픽업이 절대적으로 필요하게 된다. 그런데 광픽업의 위치추종기구인 Actuator는 정확한 위치추종(.+-.1.$\mu$m 오차이내)을 할 수 있는 성능이 요구되며 서보의 특성상 20KHz 이하에서 불필요한 모우드가 가진되지 않는 정밀부품이어야 하므로 Actuator 각 부품의 동적인 특성을 명확히 규명할 필요가 있다. 따라서 본 연구에서는 우선 Actuator 각 부품과 가동부 전체의 중량 및 진동해석을 통해 동특성을 조사하였다. 그리고 Actuator의 중요한 기본성능중 하나인 구동감도 확보여부를 검토할 필요가 있기 때문에 유한요소법 프로그램인 ANSYS를 이용하여 자기회로 부분에 대한 해석을 구하였다. 또한 가동부와 자기회로 등 하위부품을 조립하는 과정에서 발생하는 조립오차로 인해 불필요한 공진과 회전형상이 야기될 수 있으므로 동특성 및 문제점 파악을 위한 민감도 분석이 필요하다. 따라서 본 연구에서는 가동부의 관성 모멘트 값과 강체에 대한 일반식을 이용한 자체 프로그램을 작성하여 조립공차를 구하였다. 이와같은 과정을 통해 구해진 설계값을 바탕으로 실제 제작된 Actuator에 대해서는 비접촉식 측정방법을 통해 동특성값을 측정하였고 이를 해석값과 상호 비교하였다.동강성행렬법(dynamic stiffness matrix method)을 이용하여 해석하고자 한다. 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.ive structures utilized in Client/server architecture for distribution and cooperative processing of application between server and client this study presents two different data management methods under the Client/server environment; one is "Remote Data Management Method" which uses file server or database server and. the other is "Distributed Data Management Method" using distributed database management system. The result of this study leads to the conclusion that in the client/server environment although distributed application is assumed, the data could become centralized (in the case of file server or database server) or decentralized (in the case of distributed

  • PDF

Flexural Strength of Composite HSB Girders in Positive Moment (HSB 강합성거더 정모멘트부의 휨저항강도)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.389-398
    • /
    • 2010
  • The flexural strength of composite HSB I-girders under a positive moment was investigated using the moment-curvature analysis method to evaluate the applicability of the current AASHTO LRFD design specifications to such girders. A total of 2,391 composite I-girder sections that satisfied the section proportion limits of the AASHTO LRFD specifications was generated by the random sampling technique to consider a wide range of section properties. The flexural capacities of the sections were calculated inthe nonlinear moment-curvature analysis in which the HSB600 and HSB800 steels were modeled as an elasto-plastic strain-hardening material, and the concrete, as a CEB-FIP model. The effects of the ductility ratio and the compressive strength of the concrete slab on the flexural strength of the composite girders made of HSB and SM520-TMC steels were analyzed. The numerical results indicated that the current AASHTO LRFD equation can be used to calculate the flexural strength of composite girders made of HSB600 steel. In contrast, the current AASHTO LRFD equation was found to be non-conservative in its prediction of the flexural strength of composite HSB800 girders. Based on the numerical results of this study for 2,391 girders, a new design equation for the flexural strength of composite HSB800 girders in a positive moment was proposed.

Numerical analysis of pre-reinforced zones in tunnel considering the time-dependent grouting performance (터널 사전보강영역의 경시효과를 고려한 수치해석 기법에 관한 연구)

  • Song, Ki-Il;Kim, Joo-Won;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.109-120
    • /
    • 2007
  • Auxiliary support systems such as the reinforced protective umbrella method have been applied before tunnel excavation to increase ground stiffness and to prevent the large deformation. However, determination procedure of geotechnical parameters along the construction sequence contains various errors. This study suggests a method to characterize the time-dependent behavior of pre-reinforced zones around the tunnel using elastic waves. Experimental results show that shear strength as well as elastic wave velocities increase with the curing time. Shear strength and strength parameters can be uniquely correlated to elastic wave velocities. Obtained results from the laboratory tests are applied to numerical simulation of tunnel considering its construction sequences. Based on numerical analysis, initial installation part of pre-reinforcement and portal of tunnel are critical for tunnel stability. Result of the time-dependent condition is similar to the results of for $1{\sim}2$ days of the constant time conditions. Finally, suggested simple analysis method combining experimental and numerical procedure which considering time-dependent behavior of pre-reinforced zone on tunnel would provide reliable and reasonable design and analysis for tunnel.

  • PDF

Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration (디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동)

  • Park, Jung-Hoon;Choi, Nak-Sam
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.125-132
    • /
    • 2020
  • The polymerization shrinkage behavior of dimethacrylate-based composite (Clearfil AP-X, Kuraray) and silorane-based composite (Filtek P90, 3M ESPE) used for dental composite restorations was measured using digital image correlation method. The stress distribution on the surface of specimen was calculated by finite element analysis with equivalent elastic modulus and was compared with the measured shrinkage distribution. Camera images were monitored by a CCD camera during and after the irradiation of light. As a result of the DIC analysis, a non-uniform shrinkage distribution was observed in both composite resins, and the resin core inside the ring specimen had free flowability, leading to in greater shrinkage strain than the resin/ring interfacial region. It was observed that as the distance from the center of the resin increased, the radial average shrinkage strain decreased. The radial average shrinkage strain during light irradiation occurred to be 33% for P90 and 57% for AP-X of the entire strain at the end of the test. The shrinkage behavior of P90 and AP-X was measured to be significantly different from each other during light irradiation. In the resin near the resin/ring interface, it was confirmed that the tensile strain rapidly formed to increase after light irradiation, causing a tensile stressed, interface weak.

Evaluation on the biocompatibility, bone cell activity and bone regenerative capacity of chitosan-PLLA bilayer porous membrane (Chitosan-PLLA 다층 다공성 차폐막의 생체적합성, 골세포활성도 및 골재생 능력에 관한 연구)

  • Park, Jun-Beom;Nam, Sung-Heon;Kim, Kyoung-Hwa;Lee, Sang-Chul;Lee, Seung-Jin;Kim, Tae-II;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Han, Soo-Boo;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.549-561
    • /
    • 2005
  • 이 연구의 목적은 새로이 제작된 chitosan-poly(L-lactic acid)(PLLA) 다층 다공성 차폐막의 생체적합성 및 골세포활성도 및 골재생능을 평가하는 것이다. 제작된 차폐막을 24 well에 넣고 clonal osteoblast-like cell line(MC3T3-E1)을 접종한 군을 실험군으로, 차폐막을 사용하지 않은 대조군으로 하였다. 배양 1일, 7일 및 14일째에 각 well에서 세포수를 측정하였다. 주사전자현미경을 이용하여 차폐막에 부착된 세포의 형태관찰을 시행하였다. RNA 추출 및 RT-PCR을 실시한 후, agarose gel상에서 전기영동하여 조골세포 표식자인 collagen type I(COL), osteopontin(OP) 및 osteocalcin(OC) mRNA의 발현을 관찰하였다. 제작된 매트릭스의 생체적합성 및 골재생능을 관찰하기 위하여 백서의 두개골에 직경 8mm의 원형 결손부를 형성한 후 차폐막을 이식한 군을 실험군으로, 아무 것도 넣지 않은 군을 대조군으로 하여 4주 경과 후 실험동물을 희생시킨 후 조직학적관찰을 시행하였다. 시간경과에 따른 부착세포수 관찰결과, 배양 14일까지 조골세포의 수가 지속적으로 증가하였고, 주사전자현미경으로 세포의 형태 관찰결과, 배양된 세포들은 중층의 형태로 성장하면서 시간경과에 따라 세포가 응집되는 양상을 나타내었다. 관찰 기간동안 COL, OP, 및 OC mRNA의 발현이 관찰되어 배양 전 기간동안 조골세포의 형질이 잘 유지되고 있음을 알 수 있었다. 백서 두개골 결손부에 이식된 차폐막은 염증반응 없이 주위 조직과 우수한 생체적합성을 나타내었으며, 차폐막을 이식하지 하지 않은 대조군에 비해 높은 신생골 형성을 나타내었다. 이상의 관찰결과로 새로이 제작된 chitosan-PLLA 차폐막은 우수한 생체적합성 및 골재생능을 나타냄을 알 수 있었으며, 향후 이를 골조직 재생 및 치주조직유도재생 분야에 응용될 수 있을 것으로 생각된다.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

Reaction Mechanism and Curing Characteristics of Chicken Feather-Based Adhesives and Adhesive Properties of Medium-Density Fiberboard Bonded with the Adhesive Resins (닭털로 제조한 접착제의 반응기작 및 경화 특성과 이를 이용하여 제조한 중밀도섬유판의 접착 특성)

  • Yang, In;Park, Dae-Hak;Choi, Won-Sil;Oh, Sei Chang;Ahn, Dong-uk;Han, Gyu-Seong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.385-394
    • /
    • 2017
  • In this study, reaction mechanism and curing characteristics of adhesives formulated with NaOH- and $H_2SO_4$-hydrolyzed chicken feather (CF) and formaldehyde-based crosslinkers were investigated by FT-IR and DSC. In addition, adhesive properties and formaldehyde emission of medium-density fiberboards (MDF) applied with the adhesives were measured. CF-based adhesives having a solid content of 40% and over were very viscous at $25^{\circ}C$, but the viscosity reduced to $300{\sim}660m{\cdot}Pa{\cdot}s$ at $50^{\circ}C$. Consequently, the adhesives could be used as a sprayable resin. Through the FT-IR spectra of liquid and cured CF-based adhesives, addition reaction of methylol group and condensation reaction between the functional groups with the use of formaldehyde-based crosslinkers were identified. From the analysis of DSC, it was elucidated for CF-based adhesives to require a higher pressing temperature or longer pressing time comparing to commercial urea-formaldehyde (C-UF) resin. MDF bonded with CF-based adhesives, which was formulated with 5% NaOH-hydrolyzed CF (CF-AK-5%) and PF of formaldehyde to phenol mole ratio of 2.5 (PF-2.5), and pressed for 8 min had higher MOR and IB than those with other CF-based adhesives. MOR and IB of MDF bonded with the CF-based adhesives regardless of formulation type and pressing time were higher than those with C-UF resin. When the values compared with the minimum requirements of KS standard, IB exceeded the KS standard in all formulations and pressing time, but MOR of only MDF bonded with CF-AK-5% and PF-2.5 and pressed for 8 min satisfied the KS standard. What was worse, 24-TS of MDF bonded with all CF-based adhesives did not satisfied the KS standard. However, MOR and 24-TS can be improved by increasing the target density of MDF or the amount of wax emulsion, which is added to improve the water resistance of MDF. Importantly, the use of CF-based adhesives decreased greatly the formaldehyde emission. Based on the results, we reached the conclusion that CF-based adhesives formulated under proper conditions had a potential as a sprayable resin for the production of wood panels.

Relationship Between Carotid Intima-Media Thickness Using Ultrasonography and Diagnostic Indices of Metabolic Syndrome (초음파를 이용한 경동맥 내-중막 두께와 대사증후군 진단지표의 연관성)

  • Ko, Kyung-Sun;Heo, Kyung-Hwa;Won, Yong-Lim;Lee, Sung-Kook;Kim, Ki-Woong
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.285-291
    • /
    • 2009
  • The aim of the present study was undertaken to investigate the association between diagnostic indices of metabolic syndrome(MetS) with carotid intima-media thickness using ultrasonography. The participants in the study were 315 male employees without carotid atherosclerosis and other cardiovascular disease. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. Anthropometric parameters and biochemical characteristics were done using each specific equipments and the NCEP-ATP III criteria were used to define MetS. They were examined by B-mode ultrasound to measure the carotid intima-media thickness(carotid IMT) at the near and far walls of common carotid and bifurcation(bulb). The mean carotid IMT was $0.739{\pm}0.137\;mm$ and it's thickness significantly increased with the increase in age. Also, amounts of systolic and diastolic blood pressure, triglyceride and fasting glucose were significantly increased with the increase in age. Carotid IMT were significantly correlated with BMI(r=0.170, p=0.004), systolic(r=0.148, p=0.011) and diastolic blood pressure(r=0.123, p=0.036) and HDL-cholesterol(r=-0.164, p=0.005). On multiple logistic regression analysis for the diagnostic indices of MetS, carotid IMT were significantly associated with blood pressure(OR=4.220, p<0.01) and MetS(OR=1.301, p<0.05). The results indicate that blood pressure and MetS are important risk factors for carotid atherosclerosis.

  • PDF