• Title/Summary/Keyword: 경사 각도

Search Result 1,827, Processing Time 0.033 seconds

A STUDY ON THE POSTOPERATIVE STABILITY OF OCCLUSAL PLANE IN ORTHOGNATHIC SURGERY PATIENTS DEFENDING ON THE DIFFERENCE OF OCCLUSAL PLANE (악교정 수술시 교합평면의 차이에 따른 술후 안정성에 관한 연구)

  • Hwang, Chung-Ju;Lim, Seon-A
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.237-253
    • /
    • 1998
  • Surgical-orthodontic treatment is performed for the skeletal Class III patients with no remaining growth and too big a skeletal discrepancy (or camouflage treatment, and two jaw surgery is needed in order to have maximum effect in such patients. In two jaw surgery cases, surgical alteration of the occlusal plane is necessary to establish optimal function, esthetics and postoperative sability, therefore the establishment of the occlusal plane is essential in diagnosis and treatment. The object of this study is to evaluate the stability of the indiviual ideal occlusal plane bsaed on the architectural and structural craniofacial analysis of Delaires. Thus, the subjects of this study were 48 patients who underwent two jaw surgery, and divided in two groups. Each group were composed of 24patients, A group were operated with ideal occlusal plane and B group were not. Two groups were compared at the preoperative, immediate postoperative (average 4.3days), and long-term postoperative (average 1.3years) lateral cephalometric radiographs. The following results were obtained: 1. There was no significance in occlusal plane angulation between $T_2\;and\;T_3$. Average long term follow-up changes of occlusal Plane angle were $0.24^{\circ}{\pm}2.43$, with FH plane and $0.15{\circ}{\pm}2.16{\circ}$ with SN plane in all 48 patients. These results demonstrated that the occlusal plane after two jaw surgery in skeletal Class III malocclusion was stable. 2. There was no significance in postoperative stability of occlusal plane between A and B group. 3. There was no significance in postoperative stability of occlusal plane depending on surgeon and operative method within each group. 4. The postoperative changes of occlusal plane were correlated to the postoperative changes of jaw rather than tooth position. 5. There was no correlation between the postoperative changes of occlusal plane and maxillary impaction and mandibular setback with surgery.

  • PDF

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

A Study on the Potential Vegetation Recovery according to the Environment and Type of Tunnel Entrance and Exit (고속도로 터널 입·출구부 유형과 주변 환경에 따른 식생복구 잠재성에 관한 연구)

  • Lee, Sang-Cheol;Choi, Song-Hyun;Kim, Dong-Pil;Song, Jae-Tak;Oh, Hyun-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.161-172
    • /
    • 2012
  • The purpose of this study is to classify, evaluate and grade the existing highway tunnels to increase landscape and natural statistics keeping the structural safety about tunnel gates area and induce the ones that will be constructed in the future by drawing the improvements and restoring the techniques as an environment-friendly. To examine the types of tunnel gate area, total 54 tunnels were investigated by selecting Gyeongbu Expressway, Yeongdong Expressway, and Jungang Expressway. Tunnel entrances and exit ports were classified as a Wall-closed type and Protruding type, which is based on tunnel gate type. Vegetation Landscape types were classified as Multilayer-Same as the surrounding landscape_(MS), Multilayer-Difference of surrounding landscape_(MD), Single layer-Same as the surrounding landscape_(SS), Single layer-Difference of surrounding landscape_(SD), and a Desolate type which based on vegetation layers and environment-friendly. Potential vegetation recovery was identified based on the structural stability and revegetation potential of the tunnel. The factors include the structural stability of the slope height and slope gradient were selected. Revegetation potential was identified as a growth potential. This factor was used in the step to classify vegetation recovery potential of a tunnel. The result, which investigated the types of tunnel entrances and exit parts has found that the most typical in 33 places was a Wall closed type with 61.1% of the total ones. The case of vegetation landscape types was created but different from the ones surrounding it with 85.2% of the total ones. It is judged that the currently constructed vegetation of tunnel entrance and exit parts had put convenience on the safety and management before landscape consideration. In addition, tunnel entrance and exit parts with excellent potential for vegetation recovery were all Protruding type. In addition, it is judged that slope stability can easily obtain growth. Therefore, entrance and exist of the highway tunnels, which will be constructed in the future, should reflect location and the result of the natural and ecological survey in design by performing it in advance and their types, which minimize the damage area range, should be applied to the local characteristics suitably. In addition, the ecologically healthy tunnel construction should be done by introducing active vegetation recovery techniques based on its safety.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Predicting the Goshawk's habitat area using Species Distribution Modeling: Case Study area Chungcheongbuk-do, South Korea (종분포모형을 이용한 참매의 서식지 예측 -충청북도를 대상으로-)

  • Cho, Hae-Jin;Kim, Dal-Ho;Shin, Man-Seok;Kang, Tehan;Lee, Myungwoo
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.333-343
    • /
    • 2015
  • This research aims at identifying the goshawk's possible and replaceable breeding ground by using the MaxEnt prediction model which has so far been insufficiently used in Korea, and providing evidence to expand possible protection areas for the goshawk's breeding for the future. The field research identified 10 goshawk's nests, and 23 appearance points confirmed during the 3rd round of environmental research were used for analysis. 4 geomorphic, 3 environmental, 7 distance, and 9 weather factors were used as model variables. The final environmental variables were selected through non-parametric verification between appearance and non-appearance coordinates identified by random sampling. The final predictive model (MaxEnt) was structured using 10 factors related to breeding ground and 7 factors related to appearance area selected by statistics verification. According to the results of the study, the factor that affected breeding point structure model the most was temperature seasonality, followed by distance from mixforest, density-class on the forest map and relief energy. The factor that affected appearance point structure model the most was temperature seasonality, followed by distance from rivers and ponds, distance from agricultural land and gradient. The nature of the goshawk's breeding environment and habit to breed inside forests were reflected in this modeling that targets breeding points. The northern central area which is about $189.5 km^2$(2.55 %) is expected to be suitable breeding ground. Large cities such as Cheongju and Chungju are located in the southern part of Chungcheongbuk-do whereas the northern part of Chungcheongbuk-do has evenly distributed forests and farmlands, which helps goshawks have a scope of influence and food source to breed. Appearance point modeling predicted an area of $3,071 km^2$(41.38 %) showing a wider ranging habitat than that of the breeding point modeling due to some limitations such as limited moving observation and non-consideration of seasonal changes. When targeting the breeding points, a specific predictive area can be deduced but it is difficult to check the points of nests and it is impossible to reflect the goshawk's behavioral area. On the other hand, when targeting appearance points, a wider ranging area can be covered but it is less accurate compared to predictive breeding point since simple movements and constant use status are not reflected. However, with these results, the goshawk's habitat can be predicted with reasonable accuracy. In particular, it is necessary to apply precise predictive breeding area data based on habitat modeling results when enforcing an environmental evaluation or establishing a development plan.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.

A study on the limit of orthodontic treatment (교정 치료의 한계에 관한 연구)

  • Kim, Sun-Ju;Park, So-Young;Woo, Hae-Hong;Park, Eun-Jie;Kim, Young-Ho;Lee, Shin-Jae;Moon, Seong-Cheol;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.165-175
    • /
    • 2004
  • Information on the limits of treatment could allow for more rational treatment Planning and better results after treatment. From this point of view, this article has attempted to discuss the limits of orthodontic tooth movement. A relatively wider range of tooth movement is expected after Class III surgical-orthodontics than after conventional orthodontic treatment in general. The purposes of this Paper were: first, to evaluate the reliability of teeth position measuring gauge; and second, to elucidate the limits of orthodontic tooth movement. Dental casts of fifty-fine subjects were analyzed by using Set-up model checker (InVisitec Co., Korea) before and aster the Class III surgical-orthodontic treatment. The changes of maxillary and mandibular dental arch widths were also measured from the canines to the second molars. To test the inter-examiner reliability, randomly selected casts were measured by another examiner. Descriptive statistics and paired t tests were used to explain the tooth movement during treatment. The results showed a relatively good reliability of measuring instruments and a very diverse range of tooth movement. Collective changes by the orthodontic tooth movement evaluated in Class III surgical-orthodontics allowed for a suggestive interpretation of specific treatment patterns. Arch width changes during the inter-arch coordination were mainly the result of tipping in both buccal segments. Based on the results of this study, the possibility of a change in dentition as a result of orthodontic treatment should be understood in order to launch a well-organized plan of treatment.

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN (복합레진 표면에 대한 APF gel의 영향)

  • Yuk, Gun-Yeung;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Topical fluoride application for children is a widely peformed procedure in the field of pediatric dentistry to prevent dental caries. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surface of the restorative materials. The aim of this study was to evaluate the surface changes in composite resins to topical fluoride. Composite resins(Z $250^{(R)}$, Ultraseal $XT^{(R)}$ Filtek $flow^{(R)}$ $Revolution^{(R)}$, $Denfil^{(R)}$) in topical fluoride agents were immersed and their surface roughness, weight loss and SEM were evaluated. The results were as follows : 1. The 4 minutes-immersion groups showed more roughened surface than 1 minute-immersion groups and the control groups showed the smoothest surface among all the materials, and there was statistically significant difference except the revolution between the groups. 2. There was no significant difference between the 1 minute-immersion groups and 4 minutes-immersion groups in weight loss. 3. The experimental group treated with topical fluoride gel showed the generally mere roughened surface than control group in the SEM findings.

  • PDF

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.