• Title/Summary/Keyword: 경사계산

Search Result 707, Processing Time 0.032 seconds

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Distribution Characteristics and Dynamics of the Lindera sericea Population at Mt. Mudeung, Mt. Cheonbong and Mt. Chogye (무등산, 천봉산 및 조계산에서 털조장나무 개체군의 분포특성과 동태)

  • Lim, Dong-ok;Choi, Dea-hun;Yun, Hong-gyun
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.570-579
    • /
    • 2015
  • Lindera sericea, which belongs to genus Lindera in the Lauraceae family, is labeled under Least Concerned (LC) among Korean rare plants, floristics specific species IV grade and also flagpole species of the Mudeung National Park. It is distributed in Mt. Mudeung, Mt. Cheonbong and Mt. Chogye within gradients from $12^{\circ}$ to $51^{\circ}$. The slope area is from northeast to northwest sides and the altitude range of distribution site is between 220 m and 533 m. The vascular plants in the quadrate where Lindera sericea were studied were identified as a total of 72 taxa; 37 families, 54 genera, 66 species, 5 variants and 1 forma. Among the floristics specific species, IV grade species was Lindera sericea and III grade species were Stewartia pseudocamellia and Acer palmatum. Korean endemic species were Stewartia pseudocamellia and Carex okamotoi. As for the vegetation group, Quercus mongolica and Q. serratak - Lindera sericea, Styrax japonicus populations were found in Mt. Mudeung area where Lindera sericea appeared, Stewartia pseudocamellia-Lindera sericea and Sasa borealis populations were found in Mt. Cheonbong areas, Carpinus laxiflora - Lindera sericea and Sasa borealis populations were found in Mt. Chogye area, and Stewartia pseudocamellia-Lindera sericea and Sasa borealis populations were found in Songgwangsa area. A total number of 662 Lindera sericea individuals were examined. The number of trees with 1 trunk including younger individuals was 353 (53.32%), and the number of trees with 2 to 5 stems was 270 (40.79%). The number of trees with the greatest number of sprouts was 27. Of 662 trees in total, the total number of sprouts was 1,198. Among these, 699 trees (58.34%) were between 50 cm and 150 cm in height. The tallest tree was 585 cm. The most common root-collar diameter of sprouts (992, 82.81%) was under 1 cm, followed by the sprouts with collar diameter from 1.0 to 1.5 cm(156, 13.2%). Among them, the largest root-collar diameter was 3.2 cm. This Lindera sericea specimen had the tallest trunk (565 cm) which was torn lengthwise on one side. Its root and breast parts were decayed by 50% and 25 respectively. Some branches of the three trunks that were more than 4 m in length were dead in the apical portion. Therefore, it is proposed that the Korean Lindera sericea maintains an apical dominance tree type while showing morphological adaptation as a typical shrub because it autonomously decays some branches and trunks over a certain height while increasing the number of its sprouts.

Development of a Korean Standard Structural Brain Template in Cognitive Normals and Patients with Mild Cognitive Impairment and Alzheimer's Disease (정상노인 및 경도인지장애 및 알츠하이머성 치매 환자에서의 한국인 뇌 구조영상 표준판 개발)

  • Kim, Min-Ji;Jahng, Geon-Ho;Lee, Hack-Young;Kim, Sun-Mi;Ryu, Chang-Woo;Shin, Won-Chul;Lee, Soo-Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.103-114
    • /
    • 2010
  • Purpose : To generate a Korean specific brain template, especially in patients with Alzheimer's disease (AD) by optimizing the voxel-based analysis. Materials and Methods : Three-dimensional T1-weighted images were obtained from 123 subjects who were 43 cognitively normal subjects and patients with 44 mild cognitive impairment (MCI) and 36 AD. The template and the corresponding aprior maps were created by using the matched pairs approach with considering differences of age, gender and differential diagnosis (DDX). We measured several characteristics in both our and the MNI templates, including in the ventricle size. Also, the fractions of gray matter and white matter voxels normalized by the total intracranial were evaluated. Results : The high resolution template and the corresponding aprior maps of gray matter, white matter (WM) and CSF were created with the voxel-size of $1{\times}1{\times}1\;mm$. Mean distance measures and the ventricle sizes differed between two templates. Our brain template had less gray matter and white matter areas than the MNI template. There were volume differences more in gray matter than in white matter. Conclusion : Gray matter and/or white matter integrity studies in populations of Korean elderly and patients with AD are needed to investigate with this template.

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

Mapping of the Righteous Tree Selection for a Given Site Using Digital Terrain Analysis on a Central Temperate Forest (수치지형해석(數値地形解析)에 의한 온대중부림(溫帶中部林)의 적지적수도(適地適樹圖) 작성(作成))

  • Kang, Young-Ho;Jeong, Jin-Hyun;Kim, Young-Kul;Park, Jae-Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.2
    • /
    • pp.241-250
    • /
    • 1997
  • The study was conducted to make a map for selecting righteous tree species for each site by digital terrain analysis. We set an algorithmic value for each tree species' characteristics with distribution pattern analysis, and the soil types were digitized from data indicated on soil map. Mean altitude, slope, aspect and micro-topography were estimated from the digital map for each block which had been calculated by regression equations with altitude. The results obtained from the study could be summarized as follows 1. We could develope a method to select righteous tree species for a given site with concern of soil, forest condition and topographic factors on Muju-Gun in Chonbuk province(2,500ha) by the terrain analysis and multi-variate digital map with a personal computer. 2. The brown forest soils were major soil types for the study area, and 29 tree species were occurred with Pinus densiflora as a dominant species. The differences in site condition and soil properties resulted in site quality differences for each tree species. 3. We tried to figure out the accuracy of a basic program(DTM.BAS) enterprised for this study with comparing the mean altitude and aspect calculated from the topographic terrain analysis map and those from surveyed data. The differences between the values were less than 5% which could be accepted as a statistically allowable value for altitude, as well as the values for aspect showed no differences between both the mean altitude and aspect. The result may indicate that the program can be used further in efficiency. 4. From the righteous-site selection map, the 2nd group(R, $B_1$) took the largest area with 46% followed by non-forest area (L) with 23%, the 5th group with 7% and the 4th group with 5%, respectively. The other groups occupied less than 6%. 5. We suggested four types of management tools by silvicultural tree species with considering soil type and topographic conditions.

  • PDF

Analysis of the primary and the permanent teeth dimension In korean hemifacial microsomia patients (한국인 반안면 왜소증 환자의 유치와 영구치 크기에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.43-52
    • /
    • 2000
  • Hemifacial microsomia ( HFM ) is the second most common craniofacial abnormalies. HFM represnted a spectrum of clinical findings such as hypoplasia of the mandibular ramus and condyle, confinement of maxilla growth, external and/or middle ear defects, involvement of some cranial suture, buccal soft tissue, facial nerve, and muscles in the affected side. HFM often showed progressive facial asymmetry and occlusal plane slanting to the affected side with growth. There were several reports about asymmetry of tooth maturation, hypodontia, delayed eruption, enamel hypoplasia in HFM. Since teeth develope in close association with size and morphology of the maxillary and the mandible, it is highly likely that dental changes will be present in HFM. So the Purpose of this study was to investigate the differences of the primary and the permanent teeth dimensions in the maxillary and the mandibular dentition between the affected and the non-affected side of HFM.. The sample of this study consisted of 34 unilateral HFM Patients (18 males and 16 females, average age : 5 year 11 months old). The authors examined the mesiodistal and the faciolingual dimensions of the primary and the permanent teeth and performed statistical study by using paired t-test. The results were as follows 1. The mesiodistal dimensions of the mandibular second primary molar and the mandibular first permanent molar in the affected side of HFM were significantly smaller than those of non-affected side. But there were no significant differences in the anterior teeth and the mandibular first primary molar. It means that a gradient of severity from anterior teeth to posterior teeth was found in the mandibular dentition. 2. Although there were no significant differences in the faciolingual dimensions of the primary and the permanent teeth in the maxillary and the mandibular dentition between the affected and non-affected side of HFM, there were general trend of compensatory increase in faciolingual dimension of the mandibular primary and the permanent teeth in the affected side Therefore these results showed that HFM might affect on the abnormality of tooth dimension, especially the most posterior teeth, in the affected side of the mandible.

  • PDF

CRANIOFACIAL STRUCTURE AND ARCH DIMENSION OF ADULT CLASS III MALOCCLUSION (성인 III급 부정교합자의 악안면골격구조 및 치열궁형태에 관한 연구)

  • Lee, Dong-Geun;Suhr, Cheong
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.359-372
    • /
    • 1997
  • This study was conducted to discern differences of craniofacial, dentoalveolar structure and model measurements between sex and between class n openbite group and non-openbite group. The sample consisted of 49 adult patients with class Il malocclusion. 24 linear measurements, 22 angular measurements and 12 ratios were selected in lateral cephalometry. Also, arch width, length, anterior crowding, average molar relation were measured or calculated in diagnostic model. The data were evaluated by t-test and multiple discriminant analysis. The results were as follows, 1. Most linear measurements, with the exception of MnBL and AUDH, were significantly larger in male(p<0.05). but, intermaxillary relations and spatial position of maxilla and mandible relative to cranial base were not different for both sex. 2. With the exception of upper and lower anterior crowding, lower arch width, upper arch length, AMR, male exhibited significantly larger measurements in model analysis (p<0.05). 3. Size differences of maxilla and mandible between openbite and non-openbite group were not significant(p>0.05). but openbite group showed significantly increased genial angle(p<0.05), FH-CoGo(p<0.01), FH-NA(p<0.01) and FH-NB, FH-NPog (p<0.05). 4. ALFH and PUDH were larger(p<0.05) in openbite group. this result served as compensation for the spatial position of mandible relative to cranial base. AUPUDH (p<0.001) and ALPLDH(p<0.05) were lower in openbite group. upper anterior crowding was the only measurement which showed difference between openbite and non-openbite group(p<0.05). 5. For the purpose of classifying adult class n openbite and non-openbite group, multiple discriminant analysis was done genial angle, ALPLDH, AUPUDH, FH-NA were included in multiple discriminant equation. 39 cases($92.86\%$) were correctly classified when applied to the sample used in this study.

  • PDF

Design of Truck Escape Ramps (자동차 긴급 피난 차선의 계획 설계)

  • 구본충
    • Journal of the Korean Professional Engineers Association
    • /
    • v.28 no.4
    • /
    • pp.54-75
    • /
    • 1995
  • This synthesis has been prepared from a review of literature on Truck Escape Ramps technology and a survey of current practice by state department of transportation. Their locations have been determined usually from a combination of accident experience and en-gineering judgement, but new tools are emerging that can identify needs and sites without waiting for catastrophic accidents to happen. The Grade Severity Rating Systems holds promise in this regard. Design Procedures for truck excape ramps continue to evolve. Gravel arrester beds are clearly the preferred choice across the country Rounded aggregate, uniformly graded in the approximate size range of 13 to 18mm. Tech-nical publications typically have dassified TER types as paved gravity, sandpile, and ar-rester bed ramps. The design speed for vehicle entry into the ramp in critical to the deter-mination of ramp length. An escape ramp should be designed for a minimum entry speed of 130km/hr, a 145km/hr design being preferred. The ramps should be straight and their angle to the roadway align-ment should be as possible. The grade of truck escape ramps show the adjustment of ramp design to local topography, such as the tradeoff of ramp length against earthwork requirements. A width of 9 to 12m would more safety acommodate two or more outof con-trol vehicles. Reguarding comments on the most effective material, most respondents cited their own specification or referred to single graded, rounded pea gravel. The consensus essentially Is that single graded, well -rounded gravel is the most desirable material for use in arrester beds. The arrester beds should be constructed with a minimum aggregate depth of 30cm. Successful ramps have used depths between 30 and 90cm.

  • PDF

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.