• 제목/요약/키워드: 겹침 이음 길이

검색결과 41건 처리시간 0.025초

겹침이음길이 및 구속 철근에 따른 헤드철근의 구조적 성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Headed Bars by Lap Length and Confinement Details)

  • 유호일;이용택;김승훈;채서호;반병열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.286-289
    • /
    • 2006
  • Headed bars have used to the anchoring of the tension or compression longitudinal bars and of the shear reinforcing bars. Recently, lap splices of headed bars are attempted to the joints of precast concrete members and to the connections between old and new concrete members. Previous Michael's experimental research showed that confinement details had an effect on the lap splice performances of headed bars. In this study, the lap splice performances of headed bars(D25) with lap length and confinement details are evaluated through the experimental works. Four specimens, of which variables were the lap length of headed bar and the type of confine details, were tested for the performance evaluation on lap splice. Test results show that the lap length confinement reinforcement improve the performance of lap splice.

  • PDF

고강도 콘크리트 휨부재의 정착 및 겹침이음길이에 관한 실험적 연구 (Experimental Research on Development and Splices Length in High-Strength Concrete Flexural Members)

  • 이기열;김우;정기오
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.865-871
    • /
    • 2003
  • This paper presents the test results of 24 beam-end specimens to investigate the effect of concrete strength and cover thickness on the development resistance capacity in tensile lap splice length regions. The results showed that as higher strength concrete was employed, nor only development resistance capacity was influenced by cover thickness, but also more sufficient safety factor reserved shorter than the lap splice length provision in current design code. From experimental research results, high-strength concrete development length was not inverse ratio of ($\sqrt{f_{ck}}$) but directly inverse of $f_{ck}$, and it is also said that there is a certain limit length of the embedded steel over which the assumption of uniform bond stress distribution is valid specially for high-strength concrete not having a same embed length such as normal-strength concrete in current design criteria hypothesis.

  • PDF

원전구조물의 고강도철근(550MPa) 사용에 따른 기계적이음 경제성 분석 (Cost Analysis on Mechanical Splice of High-Strength Reinforcement (550MPa) used in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.155-156
    • /
    • 2019
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, lap splices of high-strength(550MPa) bars can be used but it is expected that lap splice length of reinforcement will be increased significantly. The increased lap splice length will be lead to increase in construction cost & period and to problems of other bar congestions. Therefore, this study will analyze the economic feasibility on mechanical splice of high-strength reinforcement used nuclear power plant structures instead of lap splice.

  • PDF

고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구 (A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid)

  • 이종석;김영삼;신홍철;김영근;강충모
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.153-159
    • /
    • 2014
  • 본 연구에서는 고경질 도막재로 PET 필름을 접합하는 시공방법에 있어서 PET 필름의 표면처리 조건 및 겹침이음 길이에 따른 접합특성 및 내구특성을 검토하였는데, 그 결과 무처리 보다 코로나 방전 처리에 의해 접촉각, 접합 인장강도, 벗김저항성이 개선되었다. 특히 시험체 E (코로나 방전+프라이머+강접접착제+폴리에스터 부직포)에서 가장 높은 것으로 나타났으며, 특히 겹침 이음길이 15mm 이상일 때 16주간 장기간 열화처리에도 안정적인 접합성능을 확보하는 것으로 나타나 방수재료로서 수밀성을 확보할 것으로 판단된다.

시간에 따른 F13T 고장력 볼트의 체결력 감소 (Time Dependent Reduction of Clamping Forces of High Strength Bolt F13T)

  • 조재병;성택룡
    • 대한토목학회논문집
    • /
    • 제29권4A호
    • /
    • pp.291-297
    • /
    • 2009
  • 실험을 통해 고장력 볼트의 릴렉세이션를 측정하였다. 종류와 표면 처리가 다른 볼트를 사용하여 체결길이가 서로 다른 블록형태와 겹침이음형태의 시험체를 조립하였다. 항온항습실에서 시간 경과에 따라 볼트에 도입된 축력을 변형률 게이지를 통하여 측정하였다. 볼트축력의 감소율은 모든 시험체에서 10% 미만으로 나타났다. 결합 형태, 볼트종류, 체결길이 그리고 볼트의 표면 처리가 서로 다른 여러 경우에 대해 실험결과를 이 연구에서 제안한 릴렉세이션 추정 모델을 이용하여 비교, 검토하였다. 제안한 모델은 여러 경우에 대한 실험 결과와 모두 합리적으로 잘 합치하고 있다. F13T와 F10T 볼트사이에 차이점을 발견할 수 없으나 다크로 볼트의 최종 체결력 감소율은 일반 볼트보다 30% 정도 높으며, 또한 전체적으로 볼트 체결길이가 짧아짐에 따라, 전단면의 수가 증가함에 따라 높아지는 경향을 보여주고 있다.

축방향철근 겹침이음길이에 따른 RC원형 교각의 거동특성 - 실험적 연구 - (Seismic Behavior of Circular Sectional RC Bridge Columns with Various Lap-splice Lengths - An Experimental Study -)

  • 김익현;선창호;이승화;박광순;서형열
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.47-56
    • /
    • 2012
  • It is known that seismic performance of existing bridges having insufficient lateral confinements and lap-splices of longitudinal reinforcements at the base of column decreases dramatically. In this study, small-scaled model tests have been performed to confirm the seismic behaviors of RC bridge piers with various lap-splice lengths. The 8 test models have circular section with diameters of 0.65 m, 0.8 m, 1.0 m, and lap-splice lengths of B-class or C-class. The test results show that the failure modes of models are not depending on the lap-splice length itself but depend on the ratio of lap-splice length to diameter, and that the displacement ductility is also affected by this ratio.

외피형태에 따른 GFRP 보강근의 겹침 이음길이 (Lap Splice Length of Glass Fiber Reinforced Polymer (GFRP) Reinforcing Bars with Different Surface Design)

  • 최동욱;이창호;하상수;박영환;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.449-452
    • /
    • 2004
  • The lap splice lengths of deformed steel reinforcing bars and GFRP bars with two different to surface type were experimentally compared using beam specimens. The purpose was to evaluate the length required of the GFRP bar to develop strength equivalent to the conventional steel reinforcing bar. The main test variable was the lap splice length. Two different GFRP bar surfaces were tested: (1) spiral-type GFRP bars and (2) sand coated GFRP bars. For the conventional steel bars (SD400 grade), strength over 400 MPa in tension was reached using the lap splice length of $30d_b$. Splice failure was observed in the specimen with the lap splice length of $20d_b$. For the spiral-type and sand coated GFRP bars, the tensile strength developed in the GFRP bars decreased with decreasing splice lengths. Development of the cracks on beam surfaces was clearly visible for the beams reinforced with the GFRP bars. Mid-span deflections, however, were significantly smaller than the comparable beams with conventional steel bars indicating potential ductility problem.

  • PDF

탄소섬유 메쉬를 사용한 철근콘크리트 보의 휨보강 (Flexural Strengthening of Reinforced Concrete Beams Using Carbon Fiber Mesh)

  • 서수연;윤현도;최창식;최기봉
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.181-190
    • /
    • 2005
  • 본 연구에서는 탄소섬유메쉬(Carbon Fiber Mesh, CFM)를 이용한 철근콘크리트 보의 휨보강 효과를 연구하며 CFM의 정착과 겹침이음방법에 따른 영향을 연구하고자 한다. 휨이 지배적인 5개의 철근 콘크리트 실험체를 제작하고 CFM으로 보강한 후 단순지지형태로 가력을 하여 그 보강효과를 규명하고자 한다. 보의 전체 길이는 2400mm이며 깊이와 폭이 모두 300mm로서 휨이 지배될 수 있도록 실험체를 계획하였다. 실험으로부터, 균열이 시작되는 단계에서 CFM의 보강효과는 미약한 것으로 나타났으나, 균열발생 이후에는 보의 휨강성확보의 측면에서 효과가 있는 것으로 나타났다. 보강된 실험체와 보강되지 않은 실험체의 비교를 통하여 CFM보강효과를 확인할 수 있었으며, 균열발생시와 항복시에 대하여 보강효과를 반영하여 예측한 계산값과 실험결과가 좋은 일치를 보이는 것으로 나타났다.

철근 비부착 및 절단 기법을 사용한 PC 접합부의 실험적 연구 (Experimental Study on the Precast Concrete Joint using Re-bar Debonding and Cutting Technique)

  • 이원호;문정호;이용재;이한준
    • 한국방재학회 논문집
    • /
    • 제2권4호
    • /
    • pp.131-141
    • /
    • 2002
  • 지하주차장을 PC화할 때 각각의 부재 접합상태에 따라 설계방법 및 시공방법에 많은 차이가 발생하게 된다. 특히 PC 벽체를 상호 연결하기 위한 접합부에서 수평철근을 겹침이음 방법에 의해 접합하는 경우, 수평철근의 이음길이를 충분히 확보하여야 하기 때문에 시공성이 저하되는 문제점이 있다. 따라서, PC 벽체 수평철근의 돌출길이를 최소화하기 위하여 철근 비부착 기법 및 철근 절단 기법을 적용하는 것을 본 연구의 목적으로 하고 있다. 즉, 철근 콘크리트 부재에서의 위험단면의 위치는 일반적으로 부재의 단부가 되고, 철근의 정착길이는 이 위험단면으로부터의 길이가 된다. 그런데 위험단면의 위치를 비부착 철근 공법 및 철근 절단 공법을 사용하여 부재 안쪽으로 이동함으로서, 수평철근의 정착길이를 최소화시킬 수 있다. 본 연구에서는 철근 비부착 기법 및 철근 절단 기법의 적용 가능성을 파악하기 위해 5개의 실험체를 실물크기로 제작하여 실험적 연구를 실시하고, 절단 철근 및 비부착 철근이 시험체의 거동에 미치는 영향을 비교 및 분석한 결과, 위험단면의 이동을 위하여 철근 비부착 기법 및 철근 절단 기법의 사용이 가능한 것으로 판단된다.

직선화 가공성을 고려한 코일철근의 실험적 부착강도 평가 (Experimental Evaluation on Bond Strengths of Reinforcing Bar in Coils with Improved Machinability during Straightening Process)

  • 천성철;최완철;진종민
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.53-61
    • /
    • 2013
  • 코일철근의 직선화 가공성을 향상시키기 위한 마디 형상으로, 철근 축과 마디 사이각 $50^{\circ}$, 마디 윗면 폭(crest width) $0.15d_b$, 마디의 종단면 각도(flank inclination) $55^{\circ}$에 초승달 모양 지압면을 가진 생선뼈 마디(fishbone-shaped transverse rib)를 제안하였다. 이 형상은 직선화 기계의 롤러 홈(groove)과 철근 외부의 접촉면적을 넓혀 마디 손상을 최소화하며 직선도를 향상시키고 가공 생산성을 높일 것으로 기대된다. 제안된 형상을 포함하여 마디 각도가 상이한 3종류의 코일철근(SD500D16 강종)에 대한 부착강도 평가를 위해 겹침이음실험을 실시하였다. 3종의 코일철근은 기존 부착강도 평가식에 따른 예측값보다 평균 10%이상 높은 부착강도를 지닌 것으로 평가되었다. 이것은 코일철근의 상대마디면적비가 기존 평가식 유도에 사용된 실험보다 높기 때문으로 판단된다. 부착강도에 대한 직선철근과 코일철근의 상관계수(correlation coefficient)는 0.94이상 이였으며, 코일철근의 부착성능이 직선철근과 거의 유사함을 알 수 있다. 따라서 실험에 사용된 코일철근의 정착길이와 이음길이 설계에 현행설계기준을 적용하는 것이 타당한 것으로 평가된다.