• Title/Summary/Keyword: 결정적 시험

Search Result 1,767, Processing Time 0.03 seconds

Experimental Study on Evaluation of Fatigue Crack Growth Rate of Steel Plates using Crack Opening Displacement (COD(Crack Opening Displacement) 측정을 통한 강재의 피로균열진전속도 추정에 관한 실험적 연구)

  • Kim, Kwang-Jin;Kim, In-Tae;Ryu, Yong-Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.589-597
    • /
    • 2010
  • Steel structures have a higher probability of being damaged by fatigue than by other causes of deterioration. As such, their maintenance to prevent fatigue damage is essential to sustain their safety and performance during their service period. In their maintenance, the current state of their fatigue cracks must be assessed to determine appropriate reinforcement methods and the suitable time intervals of periodic inspections when fatigue cracks are detected. Determining the crack growth rate is a successful method of predicting fractures, but it requires technical knowledge on fracture mechanics and experience in numerical methods and software for finite element analysis. In this study, a fatigue crack growth test on through-thickness cracked steel plates was conducted to assess the crack growth rate without superior technical knowledge and experience. The relationship between the Crack Opening Displacement (COD) and the crack growth rate was found in relatively long fatigue cracks.

Statistical Effective Interval Determination and Reliability Assessment of Input Variables Under Aleatory Uncertainties (물리적 불확실성을 내재한 입력변수의 확률 통계 기반 유효 범위 결정 방법 및 신뢰성 평가)

  • Joo, Minho;Doh, Jaehyeok;Choi, Sukyo;Lee, Jongsoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1099-1108
    • /
    • 2017
  • Data points obtained by conducting repetitive experiments under identical environmental conditions are, theoretically, required to correspond. However, experimental data often display variations due to generated errors or noise resulting from various factors and inherent uncertainties. In this study, an algorithm aiming to determine valid bounds of input variables, representing uncertainties, was developed using probabilistic and statistical methods. Furthermore, a reliability assessment was performed to verify and validate applications of this algorithm using bolt-fastening friction coefficient data in a sample application.

Seismic Qualification of Class 1E Battery by Combined Analysis and Testing (수치해석과 실험을 통한 안전등급 축전지의 내진검증)

  • 김영중;박성환;정태영;정정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.87-91
    • /
    • 1992
  • 축전지를 탑재한 프레임형 랙에 대한 공진탐색시험결과를 이용하여 유한요 소에 의한 수치해석모형을 결정하였다. 내진검증시험은 에이징시험을 거친 3 개의 축전지를 포함하여 28개의 축전지를 탑재한 시험랙을 대상으로 수행되 었다. 공진탐색시험으로부터 구한 모달특성치를 이용하여 지진응답을 해석하 였으며 실험치와 부합함을 확인하였다. 시험랙의 지진응답이 실제 설치될 60 개의 축전지를 갖는 전체랙의 응답보다 크므로, 시험랙에 의한 내진검증이 보다 열악한 조건에서 수행되었다고 볼 수 있다. 시험랙에 대한 내진검증시 구조부재의 구조적 안정성과 축전지의 성능유지를 확인한 바 있으므로 전체 랙의 경우에도 내진검증이 이루어졌다고 판단된다.

  • PDF

Optimal Test Instruction Set for Microprocessor Data Processing Testing (마이크로프로세서 데이터 처리 시험을 위한 최적시험명령어)

  • 안광선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 1984
  • This paper deals with the selection of minimal test instruction set for microprocessor data processing test. This test method is based on a function description of the instructions which are obtained from the data given by the user's manual. Selecting procedure is done in 3 steps: 1) a test execution graphs are represented on the instructions which are grouped functionally, 2) the essential graphs, the eliminable graphs, the eliminable graphs, and the eligible graphs are built, 3) optimal test instruction set from the essential graphs and the eligible graphs is defined. In the case of INTEL 8048, 50 test instructions can be selected optimally from 8048 instruction repertories (96 instructions)

  • PDF

A Study on Electrochemical Polarization Test for Embrittlement Damage Evaluation of Aged Cr-Mo Steel (Cr-Mo강 시효재의 취화손상 평가를 위한 전기화학적 분극시험에 관한 연구)

  • Yu, Hyo-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.411-419
    • /
    • 1999
  • It has been well recognized that a long term service at elevated temperature of $350^{\circ}C{\sim}550^{\circ}C$ induces embrittlement damage due to carbide precipitation and/or P, Sb and Sn segregation at grain boundaries and thereby deteriorates the grain boundary strength of heat resisting components in the energy-related plants. Therefore, it is very important to assess quantitatively the extent of embrittlement damage of heat resisting components to secure the reliable and efficient service condition and to prevent brittle failure in service. However, because fracture tests are limited in size and number of specimen obtained from the structural components, nondestructive test method is required. In this study, the optimum electrochemical parameters are investigated and discussed to evaluate nondestructive embrittlement damage for aged 2.25Cr-1Mo steels by means of electrochemical polarization test method (ECPTM) in proper corrosive environment. In addition, the electrochemical test results are compared with embrittlement degree evaluated by semi-nondestructive SP test.

  • PDF

Analysis on Heat Loss of Hybrid Safety Injection Tank to Predict Pressure Equalizing Time (혼합형 안전주입탱크의 압력평형 예측을 위한 열손실 평가)

  • Kim, Myoung Jun;Ryu, Sung Uk;Kim, Jae Min;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • In the event of loss of coolant accident (LOCA) and station black out (SBO) in the primary system of a nuclear reactor, the coolant water should be injected to reactor coolant system (RCS) without any intervention of operators or active components. To satisfy the requirements, hybrid safety injection tank (Hybrid SIT) was suggested by Korea Atomic Energy Research Institute (KAERI). The pressure equalizing time of Hybrid SIT is an important parameter to determine the timing of coolant injection. To predict the pressure equalizing time of the Hybrid SIT, a separate effect test facility was constructed and sensitivity tests were conducted in various conditions. The main parameter determining the pressure equalizing time was obtained from separate effect test (SET) results. The wall of condensation on the inner wall of SIT and direct contact condensation on the water surface affected to the pressure equalizing time very much. In this study, the effect of each condensation phenomena on pressure equalizing time was quantitatively analyzed from results of SET and a prediction method of pressure equalizing time was proposed.

An Analysis of Electrical and Mechanical Properties on Forest Fire of Polymer Insulator for T/L (송전용 플리머애자의 산불 영향에 따른 전기적 기계적 특성 분석)

  • Choi, I.H.;Choi, J.H.;Lee, D.I.;Min, B.U.;Sin, T.W.;Bang, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2244-2246
    • /
    • 2005
  • 우리나라 송전선로는 대부분 산지에 위치하고 있기 때문에 산불과 같은 화재가 발생 시 폴리머애자에 대한 신뢰성에 중요한 문제점을 발생시킬 수 있다. 따라서 산불의 가장자리 온도인 $600^{\circ}C$ 부근에 노출된 폴리머애자의 재질에 대한 전기적, 기계적 특성시험과 하우징 재질 특성 분석을 실시하였다. 그 결과 애자의 전기적, 기계적 시험은 기준치 이상으로 합격하였으며, 하우징 표면은 무기물이 노출되어 다공성의 특성을 보였고, 내아크시험 결과는 하부 갓의 아크소멸 시간은 A시료는 260초, 290초였고, B시료는 335초, 336초였다. 또한, 열분석 결과 $220^{\circ}C$ 근처에서 ATH의 분해가 일어나 결정수가 방출되어 실리콘 고무의 열화가 나타났다.

  • PDF

Study on the Determination of the Maximum Injection Pressure for Groundwater Rechargement (지하수 함양시 최대 주입압력 결정을 위한 연구)

  • Choi, Jin O;Jeong, Hyeon Cheol;Chung, Choong Ki;Kim, Chang Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.501-508
    • /
    • 2022
  • Required essential technique is to determine the maximum recharge pressure in the well with condition of non-ground failure for the recovery of the groundwater. Based on the classical soil mechanics, the maximum recharge pressure was estimated with the numerical anlaysis and laboratory triaxial test. In the numerical analysis, the maximum recharge pressure is defined as the ground failure stress. The ground failure of the sand was defined as the piping and the one of the caly was to the undrained failure by the confined pressure increment. In the triaxial test, the recharge pressure in the ground was modified by the back pressure in the specimen. In case of sand, the volume strain was dramatically increased at the 93 % of the maximum back pressure, same meaning of the 0 effective stress state. In case of clay, the only radial volume strain was to reached 1.5 % without failure. Therefore, The maximum recharge pressure could be determined with the numerical analysis and triaxial test.

The Influence of Bonding Parameters on the Contact Resistance, Adhesion and Reliability of Anisotropically Conductive Film(ACF) (이방성 전도 필름의 접촉 저항, 접착력 및 신뢰성에 미치는 접속 변수의 영향)

  • Im, Myeong-Jin;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.399-407
    • /
    • 1998
  • 본 연구에서는 LCD패키지용 이방성 전도 필름의 전기적, 기계적 특성 및 신뢰성에 미치는 접속 변수의 영향을 연구하였다. 이방성 전도 필름을 통한 전기적 전도 현상을 각각의 도전 입자와 기판 사이의 기계적 접촉에 의해 접촉 방향으로만 전류가 흐르게 되는 것이 주되는 전도 기구이다. 따라서 접속 압력에 따라 각각의 도전 입자의 변형으로 기판 사이의 접촉 면적이 변하는데 이방성 전도필름의 접촉 저항은 이런 접촉 변화에 의해 결정된다. 접속 압력에 따라 초기에 접촉 저항은 감소하다가 점차 접촉 저항기가 안정화되는 거동을 보였다. 그러나 높은 접속 압력에서는 오히려 저항치가 약간 증가함을 보였다. 이방성 전도 필름 접속의 접착력을 평가하기 위해 필 테스트(peel test)를 시행하였는데, 접속 압력과 접속 온도를 증가 시킬수록 이방성 전도 필름 접속의 접착력을 평가하기 위해 고온 시효 시험, 온도 사이클링 시험, 고온 고습 시험의 신뢰성 시험을 시행하였으며, 이중 고온 고습 시험이 ACF접속의 전기적, 기계적 특성에 가장 악영향을 주었다. 또 큰 압력으로 접속된 것보다 작은 압력으로 접속되었을 때, 그리고 도전입자로는 금속 코팅 된 폴리머 입자가 사용될 때 신뢰성이 상대적으로 좋은 것을 발견했다.

  • PDF

화학공장용 프로세스 펌프의 특성

  • 이동양
    • Journal of the KSME
    • /
    • v.28 no.1
    • /
    • pp.37-41
    • /
    • 1988
  • 일반적으로 화학공장에서 요구되는 프로세스 펌프는 취급하는 액의 물리적 화학적 성질 및 고 형체(solid)함량, 결정생성 여부 등을 고려 이에 충분히 견디고 유지보수가 용이하며 가격 면에 서도 저렴하고 여러 가지 운전 조건에 상응할 수 있는 호환성 있는 제품이어야 한다. 다양한 액성 및 운전조건에 적합한 펌프 선정에는 실제적인 많은 시험과 경험이 필요하다. 본 글에서는 원심펌프 선정시 보편적으로 고려되어야 할 일반사항에 대하여 기술하고자 한다.

  • PDF