• Title/Summary/Keyword: 결정성 분석

Search Result 11,210, Processing Time 0.049 seconds

The Performance Analysis of Equalizer for Next Generation W-LAN with OFDM System (OFDM 방식의 차세대 무선 LAN 환경에서 등화기의 성능 분석)

  • Han, Kyung-Su;Youn, Hee-Sang
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.1
    • /
    • pp.44-51
    • /
    • 2002
  • This paper describes the performance evaluation and analysis of an Orthogonal Frequency-Division Multiplexing (OFDM) system having the least Inter Symbol Interference (ISI) in a multi-path fading channel environment. Wireless Local Area Network (W-LAN) in accordance with IEEE 802.11a and IEEE 802.11b provides high-speed transmission to universities, businesses and other various places. In addition, service providers can offer a public W-LAN service on restricted areas such as a subway. The proliferation of W-LAN has led to greater W-LAN service demands, but problems are also on the rise in offering a good W-LAN service. In particular, urban areas with high radio wave interference and many buildings are vulnerable to deteriorated QoS including disconnected data and errors. For example, when high-speed data is transmitted in such areas, the relatively high frequency generates ISI between Access Points (AP) and Mobile Terminals (such as a notebook computer), leading to a frequency selective fading channel environment. Consequently, it is difficult to expect a goodW-LAN service. The simulation proves that the OFDM system enables W-LAN to implement QoS in high-speed data transmission in a multi-path fading channel environment. The enhanced OFDM performance with 52 sub-carriers is verified via data modulation methods such as BPSK, QPSK and 16QAM based on IEEE 802.11a and punched convolutional codes with code rate of 1/2 and 3/4 and constraint length of 7. Especially, the simulation finds that the OFDM system has better performance and there is no data disconnection even in a mobile environment by applying a single tap equalizer and a decision feedback equalizer to a mobile channel environment with heavy fading influence. Given the above result, the OFDM system is an ideal solution to guarantee QoS of the W-LAN service in a high-speed mobile environment.

  • PDF

Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion (CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석)

  • Chang, You-Song;Cho, Kil-Ho;Byun, Woo-Mock;Hwang, Mi-Soo;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.127-134
    • /
    • 1993
  • Percutaneous needle biopsy of pulmonary lesion with use of fluoroscopic guidance is well established as a diagnostic tool but limited by the small size and inaccessibility of certain lesions. However, percutaneous needle biopsy has been used increasingly in relation to advance and the safty of smaller biopsy needle and new imaging modalities such as ultrasound and CT. CT, because of its characteristics of high resolution, allows tissue sampling with considerable safety from area that heretofore could not be visualized under fluoroscopy. The authors summarized 44 pulmonary lesions that underwent CT-guided transthoracic biopsy with fine-needle over a 14 month period and analyzed the sensitivity of PTNB. CT-guided PTNB was done with 20 gauge or 22 gauge Westcott biopoy needle(Manan medical products, USA). A diagnosis was made in 27 of 44 cases(61%) including malignany in 19 of 24 cases and benignancy in 8 of 20 cases. The pulmonary mass lesions were located at the peripheral zone of the lung field in 33 cases and at the central zone in 11 cases. Complications were observed in 2 cases which were pneumothorax and hemoptysis each but specific therapy was not required. The sensitivity of PTNB by one session was 61%(27/44). The sensitivity of malignancy was 79%(19/24) and benignancy was 40%(8/20). These results suggest the usefulness of PTNB using fine needles be increased in earlier diagnosis and improved staging of pulmonary nodular lesions without significant complications.

  • PDF

Cloning and Characterization of Xylanase 11B Gene from Paenibacillus woosongensis (Paenibacillus woosongensis의 Xylanase 11B 유전자 클로닝과 특성분석)

  • Yoon, Ki-Hong
    • Microbiology and Biotechnology Letters
    • /
    • v.45 no.2
    • /
    • pp.155-161
    • /
    • 2017
  • A gene coding for the xylanase predicted from the partial genomic sequence of Paenibacillus woosongensis was cloned by PCR amplification and sequenced completely. This xylanase gene, designated xyn11B, consisted of 1,071 nucleotides encoding a polypeptide of 356 amino acid residues. Based on the deduced amino acid sequence, Xyn11B was identified to be a modular enzyme, including a single carbohydrate-binding module besides the catalytic domain, and was highly homologous to xylanases belonging to glycosyl hydrolase family 11. The SignalP4.1 server predicted a stretch of 26 residues in the N-terminus to be the signal peptide. Using DEAE-Sepharose and Phenyl-Sepharose column chromatography, Xyn11B was partially purified from the cell-free extract of recombinant Escherichia coli carrying a copy of the P. woosongensis xyn11B gene. The partially purified Xyn11B protein showed maximal activity at $50^{\circ}C$ and pH 6.5. The enzyme was more active on arabinoxylan than on oat spelt xylan and birchwood xylan, whereas it did not exhibit activity towards carboxymethylcellulose, mannan, and para-nitrophenyl-${\beta}$-xylopyranoside. The activity of Xyn11B was slightly increased by $Ca^{2+}$ and $Mg^{2+}$, but was significantly inhibited by $Cu^{2+}$, $Ni^{2+}$, $Fe^{3+}$, and $Mn^{2+}$, and completely inhibited by SDS.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Radiographic Findings and Atelectasis in Children Admitted to Hospital with Acute Asthma (입원한 천식 환아들의 흉부 방사선 소견과 무기폐)

  • Jung, Yoo-Jin;Jung, Hye-Jin;Lee, Kyung-Yil;Lee, Won-Bae;Yang, Dong-Hurn
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.519-523
    • /
    • 2002
  • Purpose : We aimed to evaluate the abnormalities of chest radiographs including atelectasis in children who were admitted with bronchial asthma. Methods : We retrospectively analyzed the 357 chest radiographs and the clinical and laboratory features of the 144 children with asthma, who were admitted at Daejoen St. Mary's Hospital from April 1994 to May 1998. Results : Clinical and laboratory characteristics were as follows : male to female ratio, 2.1 : 1; mean age, 4.8 years of age; mean numbers of admission, 2.5; mean hospitalization, 5.0 days; mean IgE, 387 IU/mL; mean eosinophil count, $362/mm^3$. In the abnormal findings of the 357 radiographs, there were 314 cases(88.0%) of hyperinflation, pulmonary infiltration 35.0%, atelectasis 5.3% and pneumomediastinum 0.3%. All(19) cases of atelectasis were observed in the right lung field with mostly segmental and lobular distribution, except one with lobar involvement. Atelectasis was predominant in males and those under 2 years of age. There was a tendency that the right upper lung was more involved under two years while the right lower lung was more involved over seven years of age. Conclusion : Radiographs of children admitted to hospital with bronchial asthma showed abnormal findings including pneumonia or atelectasis(5.3%). These abnormal findings can help to determine other therapeutic modalities in addition to asthma treatment.

Automatic Generation of DB Images for Testing Enterprise Systems (전사적 응용시스템 테스트를 위한 DB이미지 생성에 관한 연구)

  • Kwon, Oh-Seung;Hong, Sa-Neung
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.37-58
    • /
    • 2011
  • In general, testing DB applications is much more difficult than testing other types of software. The fact that the DB states as much as the input data influence and determine the procedures and results of program testing is one of the decisive reasons for the difficulties. In order to create and maintain proper DB states for testing, it not only takes a lot of time and efforts, but also requires extensive IT expertise and business knowledge. Despite the difficulties, there are not enough research and tools for the needed help. This article reports the result of research on automatic creation and maintenance of DB states for testing DB applications. As its core, this investigation develops an automation tool which collects relevant information from a variety of sources such as log, schema, tables and messages, combines collected information intelligently, and creates pre- and post-Images of database tables proper for application tests. The proposed procedures and tool are expected to be greatly helpful for overcoming inefficiencies and difficulties in not just unit and integration tests but including regression tests. Practically, the tool and procedures proposed in this research allows developers to improve their productivity by reducing time and effort required for creating and maintaining appropriate DB sates, and enhances the quality of DB applications since they are conducive to a wider variety of test cases and support regression tests. Academically, this research deepens our understanding and introduces new approach to testing enterprise systems by analyzing patterns of SQL usages and defining a grammar to express and process the patterns.

Distribution and Identification of Halophilic Bacteria in Solar Salts Produced during Entire Manufacturing Process (천일염 생산공정별 미생물 분포 조사 및 호염미생물 동정)

  • Na, Jong-Min;Kang, Min-Seung;Kim, Jin-Hyo;Jin, Yong-Xie;Je, Jeong-Hwan;Kim, Jung-Bong;Cho, Young-Sook;Kim, Jae-Hyun;Kim, So-Young
    • Microbiology and Biotechnology Letters
    • /
    • v.39 no.2
    • /
    • pp.133-139
    • /
    • 2011
  • In this study, we determined the changes in microbial numbers in solar salts according to the manufacturing process and storage duration. The salt samples were harvested from salt farms in Shinan (area 2) and Yeonggwang (area 1). They were serially diluted ten-fold and then placed on 4 kinds of cultivable media (mannitol salt agar, eosin methylene blue, plate count agar, and trypticase soy agar). After incubation, we obtained 62 halophilic isolates from the salt samples. Coliform and general bacteria were not detected in all salt samples. By 16S rRNA sequencing analysis, we found 12 kinds of halophilic bacteria belonging to the genera Halobacillus, Halomonas, Bacillus, Idiomarina, Marinobacter, Pseudoalteromonas, Vibrio, Salinivibrio, Virgibacillus, Alteromonas, Staphylococcus and some un-known stains. In our study, we discovered two novel species that have a 16S rDNA sequence similarity below 97%.

A STUDY ON THE ROLL-ALONG TECHNIQUE USED IN 2D ELECTRICAL RESISTIVITY SURVEYS (2차원 전기비저항 탐사에 사용되는 ROLL-ALONG 기법에 대한 고찰)

  • WonSeokHan;JongRyeolYoon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.155-164
    • /
    • 2003
  • The validity and efficiency of the roll-along technique widely used in 2-D electrical resistivity survey are analyzed in case of the dipole-dipole and the Wenner-Schlumberger arrays by numerical modelling. The shallow anomalous resistivity bodies are successfully inverted both in the dipole-dipole and in the Wenner-Schlumberger arrays because the shallow data of pseudosection are not omitted by the roll-along technique. However, the deep anomalous resistivity bodies can not be well resolved due to the skip of observed data which is more significant in the Wenner-Schlumberger array having relatively poor horizontal coverage of obtaining data. Carrying out electrical survey adopting the dipole-dipole array, the skip of data is insignificant because it is unfeasible to expand the electrodes to the maximum electrode separation coefficient($n_max$) owing to low S/N ratio. In case of the Wenner-Schlumberger array, however, because it is generally feasible to expand the electrodes $n_max$ to the owing to high S/N ratio, it is highly possible that skip of data from the roll-along technique causes significant distortion of inversion results. Therefore, adopting the Wenner-Schlumberger array having deeper median depth(Edwards, 1977) than do the dipole-dipole array on condition of the same unit electrode spacing( ($a$) ) and $n_max$, it is recommended to determine $a$ based on not $n_max$but $n_prob$free from the skip of observing data and forward electrodes with keeping overlap interval 3/4 of the survey line length in order to reduce the distortion of resistivity structure and perform resistivity survey efficiently. These results are confirmed by numerical modelling.

  • PDF

The Difference in the Latitude of Price Acceptance between On- and Off-line transaction in Stock Industry (증권업의 온라인과 오프라인간 가격수용범위 (latitude of price acceptance) 차이에 관한 연구)

  • Hong, Jae-Weon;Kwak, Young-Sik
    • Journal of Global Scholars of Marketing Science
    • /
    • v.13
    • /
    • pp.71-88
    • /
    • 2004
  • Although the factors that affect the width of latitude of price acceptance is well documented, the attempt to develop a practice-oriented methodology to calibrate the region of price insensitivity (i.e., a latitude of price acceptance) for a given individual brand has been relatively rare. The researcher aims to try to full this gap by developing a conjoint analysis-based procedure that can be applied to many industries. Furthermore, we examine the difference in the latitude of price acceptance between on- and off-line transaction in stock industry in Korea. The conjoint analysis-based procedure was applied to measure the disaggregate price response curve for individual stock investment both on- and off line transaction channel. The curves from the samples enable us to estimate the individual choice probabilities corresponding to applied price points. Using t-test the differences in mean choice probabilities between the list price and another price point were tested, through which we can get the latitude of price acceptance for a given brand in stock market. These procedures were tested in on- and off-line stock market in South Korea. The results showed that investors on off-line channel have wider latitudes of price acceptance than the investors on on-line transaction system.

  • PDF

Analysis of Characteristics of Medical Accidents and Disputes in Orthodontic Area (교정과영역의 의료사고 및 분쟁의 성격분석)

  • Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.1-22
    • /
    • 1999
  • As people are more concerned about their health and medical care, there have been an increasing number of medical disputes due to increased medical demand. In order to prevent and provide solution to currently surging medical accidents and disputes related to orthodontic treatment, in July 1998, the Korean Association Of Orthdontists surveyed 2,200 members of Korean Association of orthodontists on 30 items to recognize the pattern of medical accidents and prevent them. The survey was about accident-related items including personal profiles of members and patients who have undergone medical accidents or disputes, the cause and solution to the accidents, cautions related to members orthodontic treatment, and medical recording and archival. Based on the survey result, we analyzed characteristics of medical accidents and disputes in orthodontic area. It is more important to predict and prevent possible medical accidents or disputes based on current situation than to solve them after disputes occur. For this, we should not be negligent in raising treatment proficiency level based on patient-doctor trust and in obtaining new medical information. We should also provide medical environment where Patients themselves can decide whether to get treatment after they are offered detailed explanation on diagnosis, treatment procedure, complication, and possible hazard. We should take caution when treating patients and pay attention to charting and maintenance, which is the most fundamental, as well. Also at the Korean Association of orthodontists level, it is desired to provide education program on prevention and solution to medical accidents and disputes, and actions and organizations that can help when accidents and disputes occur.

  • PDF