• Title/Summary/Keyword: 검출키

Search Result 152, Processing Time 0.019 seconds

DNA Watermarking Method based on Random Codon Circular Code (랜덤 코돈 원형 부호 기반의 DNA 워터마킹)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.3
    • /
    • pp.318-329
    • /
    • 2013
  • This paper proposes a DNA watermarking method for the privacy protection and the prevention of illegal copy. The proposed method allocates codons to random circular angles by using random mapping table and selects triplet codons for embedding target with the help of the Lipschitz regularity value of local modulus maxima of codon circular angles. Then the watermark is embedded into circular angles of triplet codons without changing the codes of amino acids in a DNA. The length and location of target triplet codons depend on the random mapping table for 64 codons that includes start and stop codons. This table is used as the watermark key and can be applied on any codon sequence regardless of the length of sequence. If this table is unknown, it is very difficult to detect the length and location of them for extracting the watermark. We evaluated our method and DNA-crypt watermarking of Heider method on the condition of similar capacity. From evaluation results, we verified that our method has lower base changing rate than DNA-crypt and has lower bit error rate on point mutation and insertions/deletions than DNA-crypt. Furthermore, we verified that the entropy of random mapping table and the locaton of triplet codons is high, meaning that the watermark security has high level.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF