• Title/Summary/Keyword: 검출기

Search Result 2,229, Processing Time 0.293 seconds

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

A Study on Multiuser Detector for MC-DS/CDMA System (MC-DS/CDMA 시스템을 위한 다중 사용자 검출에 관한 연구)

  • 우대호;조남현;장병건;윤태성;변윤식
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.919-922
    • /
    • 2001
  • 다중 반송파를 사용하는 직접 확산 코드 분할 다중 접속 방식에서는 다중 사용자들에 의해서 시스템의 성능에 영향을 미치는 문제인 다중 사용자 간섭이 발생된다. 이 문제를 해결하기 위해서 사용된 기법이 다중 사용자 검출이다. 기존 방안으로 부공간 최소 평균 제곱 에러 다중 사용자 검출기가 존재한다. 이 검출기는 정확한 타이밍과 채널에 대한 정보가 필요하다. 이에 이점을 극복하기 위해서 부공간 MMSE 구조에 적응 구조를 더하여 검출 능력을 향상 시키고자 하였다. 모의 실험 결과 제안된 검출기가 기존 검출기 보다 BER 10/sup -3/ 기준에서 약 0.5[dB]의 신호대 잡음 이득을 얻을 수 있음을 나타내고 있다. 따라서 제안된 검출기가 기존 검출기보다 더 나은 성능을 지니고 있음을 알 수 있다.

  • PDF

Correction of the Characteristic of Response of X-ray Detector Using Linear Modeling. (선형화 모델링을 이용한 디지털 X-선 검출기 반응 특성의 보정)

  • Park, Hyun-Sun;Jang, Seok-Hwan;Huh, Young;Kim, Whoi-Yul
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.539-542
    • /
    • 2001
  • 본 논문에서는 검출기의 반응 특성을 선형화 모델링 하여 정규화 할 수 있는 방법을 제안한다. 디지털 의료영상 시스템에서 X-선을 검출하는 검출기의 반응 특성이 모든 검출기마다 다르기 때문에 이 특성을 쉽고 빠르게 정규화 하는 방법이 필요하다. 본 논문에서는 균일한 피사체에 X-선 조사량의 비율을 다르게 하여 두 번 찍은 영상으로 검출기의 반응 특성을 정규화 한다. 실험 결과 일정한 두께의 납 평판에 조사량을 달리하여 촬영한 두 개의 결과 영상을 가지고 검출기의 반응 특성을 보정하면 매우 안정된 결과 영상을 얻을 수 있다.

  • PDF

Development of Control System for Thimble Handling Equipment for Neutron Flux Mapping (노내 핵계측 검출기 안내관 인출 및 삽입 장비 제어시스템의 개발)

  • Byun, Seung-Hyun;Cho, Byung-Hak;Park, Joon-Young;Lee, Jae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1995-1996
    • /
    • 2006
  • 검출기 안내관은 노내 핵계측 계통의 중성자 분포 측정을 위한 이동형 검출기의 이동경로를 제공할 뿐만 아니라 원자로 냉각수 계통의 압력경계를 유지하는 안전성 등급의 중요한 설비이다. 그러나, 인출과 삽입을 위한 검출기 안내관 취급은 의외로 낙후되어 작업자의 인력에만 의존하고 있는 실정이며, 원자로 격납용기 내부에 위치한 고방사선 지역에서 작업이 수행되고 있는 실정이다. 따라서 노내 핵계측 계통의 검출기 안내관의 안정적인 관리를 위해 검출기 안내판을 일정한 힘으로 인출하고 삽입할 수 있는 자동화시스템의 개발이 이루어지고 있다. 전력연구원에서 개발한 안내관 취급기구는 롤러에 의해 안내관을 파지하고, DC 모터 구동에 의해 안내관을 인출하고 삽입하는데, 본 논문에서는 안내관 취급 기구의 제어 시스템 구성과, 롤러와 안내관 사이에 발생하는 슬립을 고려한 제어기 구조를 제안하고, 실험을 통해 구현한 제어 시스템의 효용성을 보인다.

  • PDF

방사선동위원소를 이용한 밀도/수분함량 측정계기의 회로설계

  • 송정호;황주호;길경석;김기준
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.365-372
    • /
    • 1997
  • 이 연구의 목적은 밀도측정 및 수분함량측정용 RI 계기의 개발에 있다. 방사성동위원소를 이용하여 성토시공의 현장다짐 밀도 및 수분함량 측정에 이용되곤 있는 RI 계기는 중성자 검출부분, 감마선 검출부분, 고전압 공급부분, 마이크로 컴퓨터 부분으로 크게 나눌 수 있다. 감마선을 검출하는 G-M 검출기는 그 특징으로 인해 방사선검출 전기회로가 간단하다. 그러나 열중성자를 검출하는 He-3 검출기는 검출기에서 발생하는 신호원이 매우 작아서 검출회로의 상호 간섭으로 인한 전기적 잡음이 발생한다 이 잡음을 제거하는 것이 He-3 중성자 검출기로 열중성자를 검출하는데 중요한 문제이다. 본 연구에서 제작하는 RI 계기는 원자력법에서 제한하는 방사능 이하를 (100$\mu$Ci 의 밀봉선원) 사용하므로 종래의 RI 계기에 비해 방사선의 검출수가 줄어든다. 이에 따라 검출기의 개수를 늘려서 방사선을 검출해야 한다. 또한 본 연구에서는 He-3검출기의 검출 스펙트럼을 분석하여 적정한 방사선 검출 측정영역을 결정하였다.

  • PDF

A Study on the Germanium Radiation Detector Compensated by Gamma-ray Irradiation

  • Moon, P.S.
    • Nuclear Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.85-94
    • /
    • 1975
  • The n-type germanium crystals have been irradiated by $^{60}$ Co gamma-ray with 647 Mrad at room temperature for compensation. The Ge(${\gamma}$) detectors were fabricated from the gamma-ray irradiated germanium single crystals. The detector characteristics of the Ge (${\gamma}$) detectors were comparable to those of thin Ge(Li) detectors and high purity germanium detectors. The thermal stability of the Ge (${\gamma}$) detector showed a feasibility for ambient temperature storage.

  • PDF

Image System Using Dual Energy Detector (이중 에너지 검출기를 이용한 영상 시스템)

  • Yeo, Hwa-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3517-3523
    • /
    • 2010
  • Single exposure dual X-ray imaging can be used to separate soft and dense-material images for medical and industrial applications. This study keep focusing baggage inspection system(BIS) specifically. New detector modules for single exposure dual X-ray imaging are consisted of low energy detector (LED) and high energy detector (HED). First, the optimized thickness of copper filter coupled HED to separate low energy and high energy was simulated by the given X-ray energy (140 kVp, 1 mA) using Monte Carlo simulation codes, MCNPX. So as a result of simulation, the copper filter thickness is 0.7 mm. For the design of PIN photodiode, ATLAS device simulation tool was used. 16 channels PIN photodiode of 1.5 mm ${\times}$ 3.2 mm for Dual X-ray imaging detector was fabricated in the process of ETRI. And its dark current and quantum efficiency, terminal capacitance were measured. It was proven that the Lanex Fast B coupled HED were a sufficient candidate to replace the CsI(Tl) commerced in dual X-ray system, since these give a strong signal, overcoming system noise. Finally dual X-ray image was acquired through correction of the LED X-ray Image and the HED X-ray Image.

Low-Noise Detector Design for Measuring the Electric Conductivity of Liquids (액체의 전기 전도도 측정을 위한 저잡음 검출기 설계)

  • Kim, Nam Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.287-292
    • /
    • 2012
  • In this paper, design of a conductivity detector using a synchronous demodulation is presented to detect the electric conductivity of liquids with low noise. For the purpose, the detector is constructed by the combination of a carrier generator, conductivity detecting cell, and synchronous demodulator. The signal-to-noise ratio(SNR) of the detector is improved by adjusting the frequency bandwidth of the demodulator, whereby infinitesimal conductivity signals can easily be measured under various noise environments. As an application example, a conductivity detector, which is applied to the air monitoring in a fabrication process of semiconductor chips, is designed using the synchronous demodulation. The validity of the design technique is verified by experiments. Since experimental results are shown to approach the design performance of the detector, the synchronous demodulation proves to be useful to the design of a conductivity detector for measuring the infinitesimal electric conductivity of liquids.

Statistical Model-Based Voice Activity Detection Using the Second-Order Conditional Maximum a Posteriori Criterion with Adapted Threshold (적응형 문턱값을 가지는 2차 조건 사후 최대 확률을 이용한 통계적 모델 기반의 음성 검출기)

  • Kim, Sang-Kyun;Chang, Joon-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.76-81
    • /
    • 2010
  • In this paper, we propose a novel approach to improve the performance of a statistical model-based voice activity detection (VAD) which is based on the second-order conditional maximum a posteriori (CMAP). In our approach, the VAD decision rule is expressed as the geometric mean of likelihood ratios (LRs) based on adapted threshold according to the speech presence probability conditioned on both the current observation and the speech activity decisions in the pervious two frames. Experimental results show that the proposed approach yields better results compared to the statistical model-based and the CMAP-based VAD using the LR test.

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.