• Title/Summary/Keyword: 검출기교정

Search Result 113, Processing Time 0.025 seconds

Dependence Evaluation of the Self-Absorption Correction Factor for p-type High Purity Germanium Detector Characteristics (p-type HPGe 검출기 특성에 따른 밀도 보정인자 의존도 평가)

  • Jang, Mee;Ji, Young-Yong;Kim, Chang-Jong;Lee, Wanno;Kang, Mun Ja
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The precise determination of the activity for each radionuclide in environmental samples requires the self-absorption correction factor. In this research, we derived the self-absorption correction factor for three p-type high purity germanium detectors using the Monte Carlo code MCNPX. These detectors have different characteristics such as crystal diameter, height and size of the core. We compared the calculated full-energy peak efficiency with the experimental value using a standard sample with $1g/m^3$ density and verified the modeling. We simulated the dependency of the full-energy peak efficiency on the 0.3, 0.6, 0.9, 1.0, 1.2 and $1.5g/m^3$ samples and obtained the corresponding self-absorption correction factor. The self-absorption correction factors calculated for the three detectors differ by less than 1% over most of the energy range and sample densities considered. This indicates that the self-absorption correction factors are independent of the crystal characteristics of HPGe detector.

The Study of CsI(Tl) Scintillation Detector Design and Signal Processing for the Measurement of the Radiation Distribution (방사선 분포측정용 CsI(Tl) 검출기 설계 및 신호처리에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho;Kim, Jong-yeol;Jeong, Sang-hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.778-779
    • /
    • 2016
  • In This paper, We designed the scintillation detector for measuring radiation signals in units of pixels for a radiation source that is distributed in the space. And we carried out a study to design a radiation imaging by the module for obtaining the detection signal. For measuring radiation distribution we configure a radiation detector combining CsI(Tl) scintillator and a photodiode. In addition, its performance was verified via gamma irradiation test.

  • PDF

A Method for Detection and Correction of Pseudo-Semantic Errors Due to Typographical Errors (철자오류에 기인한 가의미 오류의 검출 및 교정 방법)

  • Kim, Dong-Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.10
    • /
    • pp.173-182
    • /
    • 2013
  • Typographical mistakes made in the writing process of drafts of electronic documents are more common than any other type of errors. The majority of these errors caused by mistyping are regarded as consequently still typo-errors, but a considerable number of them are developed into the grammatical errors and the semantic errors. Pseudo semantic errors among these errors due to typographical errors have more noticeable peculiarities than pure semantic errors between senses of surrounding context words within a sentence. These semantic errors can be detected and corrected by simple algorithm based on the co-occurrence frequency because of their prominent contextual discrepancy. I propose a method for detection and correction based on the co-occurrence frequency in order to detect semantic errors due to typo-errors. The co-occurrence frequency in proposed method is counted for only words with immediate dependency relation, and the cosine similarity measure is used in order to detect pseudo semantic errors. From the presented experimental results, the proposed method is expected to help improve the detecting rate of overall proofreading system by about 2~3%.

Detecting Spelling Errors by Comparison of Words within a Document (문서내 단어간 비교를 통한 철자오류 검출)

  • Kim, Dong-Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.12
    • /
    • pp.83-92
    • /
    • 2011
  • Typographical errors by the author's mistyping occur frequently in a document being prepared with word processors contrary to usual publications. Preparing this online document, the most common orthographical errors are spelling errors resulting from incorrectly typing intent keys to near keys on keyboard. Typical spelling checkers detect and correct these errors by using morphological analyzer. In other words, the morphological analysis module of a speller tries to check well-formedness of input words, and then all words rejected by the analyzer are regarded as misspelled words. However, if morphological analyzer accepts even mistyped words, it treats them as correctly spelled words. In this paper, I propose a simple method capable of detecting and correcting errors that the previous methods can not detect. Proposed method is based on the characteristics that typographical errors are generally not repeated and so tend to have very low frequency. If words generated by operations of deletion, exchange, and transposition for each phoneme of a low frequency word are in the list of high frequency words, some of them are considered as correctly spelled words. Some heuristic rules are also presented to reduce the number of candidates. Proposed method is able to detect not syntactic errors but some semantic errors, and useful to scoring candidates.

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

A study on slim-hole neutron logging based on numerical simulation (소구경 시추공에서의 중성자검층 수치모델링 연구)

  • Ku, Bonjin;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.219-226
    • /
    • 2012
  • This study provides an analysis on results of neutron logging for various borehole environments through numerical simulation based on a Monte Carlo N-Particle (MCNP) code developed and maintained by Los Alamos National Laboratory. MCNP is suitable for the simulation of neutron logging since the algorithm can simulate transport of nuclear particles in three-dimensional geometry. Rather than simulating a specific tool of a particular service company between many commercial neutron tools, we have constructed a generic thermal neutron tool characterizing commercial tools. This study makes calibration chart of the neutron logging tool for materials (e.g., limestone, sandstone and dolomite) with various porosities. Further, we provides correction charts for the generic neutron logging tool to analyze responses of the tool under various borehole conditions by considering brine-filled borehole fluid and void water, and presence of borehole fluid.

Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma (플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • An ion energy spectrometer which has the $45^{\circ}$ parallel electrostatic deflection plate was designed and constructed for measuring ion temperature in high temperature plasma. The energy calibration and the energy resolution were studied in detail for a hydrogen ion at the $0.24{\sim}1.92\;keV$ energy using electrostatic accelerator with a duoplasmatron ion source. The voltage of the deflection plate was linearly increased for the decreased ion detector position at the constant ion energy and decreased for the increased ion energy at the fixed ion detector position. The inclination of the deflection plate voltage to the ion energy was between 0.92 and 1.61, and linearly decreased for the increased the ion detector position. The measured energy resolution, which is $4.2%\;{\sim}\;11.6%$ in this experiment region, was improved for the increased ion dector position and ion energy. The relative efficiency was increased for the decreased the ion detector position. The ion energy spectrum of the DC plasma in the multi-purpose plasma generator was measured using this equipment. The ion temperature was 203-205 eV at the discharge voltage 320 V, discharge current 1.7 A.

  • PDF

Slant Estimation and Correction for the Off-Line Handwritten Hangul String Using Hough transform (Hough 변환을 이용한 오프라인 필기 한글 문자열의 기울기 추정 및 교정)

  • 이성환;이동준
    • Korean Journal of Cognitive Science
    • /
    • v.4 no.1
    • /
    • pp.243-260
    • /
    • 1993
  • This paper presents an efficient method for estimationg and correcting the slant of off-line handwritten Hangul strings.In the proposed method,after extracting contours from input image.Hough tranform is applied to the contours to detect lines and estimate slants of the lines.When Hough trans form is applied to the contours,pixels which are not parts of the same stroke could be detected as a line.In order to exclude these lines from slant estimation process,detected lines which have the length less than threshold are eliminated.Experiments have been performed with address images which were extracted from live envelopes provided by Seoul Mail Center.Experimental results show that the proposed method is superior to the previous methods,which had been done with handwritten English strings.in estimation the slant of off-line handwritten Hangul strings.

Investigation on the techniques of quality control for radiation counting systems (방사선 측정기의 품질관리 기법에 대한 고찰)

  • Song, Byoung-Chul;Kim, Young-Bok;Han, Sun-Ho;Oh, Se-Jin;Lee, Myung-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.414-420
    • /
    • 2011
  • In this study, radiation measurement system has been investigated to set up for the radioisotopes analysis in the radioactive waste samples after selecting the radiation counters of alpha beta and gamma nuclides. The counting efficiencies for alpha, beta and gamma measurement systems were calibrated. To obtain stability of the radiation detectors, quality control program has been established. Also, minimum detectable activities (MDAs) depending on the type of samples were calculated for increasing the confidence level for analytical result.