• Title/Summary/Keyword: 검출감도

Search Result 359, Processing Time 0.022 seconds

Quality Comparison between Gamma Irradiation and Freeze Drying Methods in Preparing Kimchi for the Long-term Storage (장기저장이 가능한 김치제조를 위한 감마선 조사와 동결건조법의 품질비교)

  • Park, Jin-Gyu;Park, Jae-Nam;Han, In-Jun;Song, Beom-Seok;Kim, Jae-Hun;Lee, Ju-Woon;Hwang, Han-Joon;Kim, Young-Duk;Byun, Myung-Woo
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • This study compared microbial load, texturre, histological properties, and sensory characteristics of gamma-irradiated (20 kGy) Kimchi and freeze-dried Kimchi under condition; of long-tenn storage. immediately after irradiation, no aerobic bacteria were detected, but microbial load of freeze-dried Kimchi decreased by only 1 log cycle in comparision with the nonirradiated control sample. The firmness of irradiated Kimchi was significantly higher than that of rehydrated freeze-dried Kimchi (p<0.05). Scanning electron microscopy showed collapse of the microstructure in epidermis tissues of rehydrated Kimchi. 'The sensory scores for color, texture, and taste of irradiated Kimchi were higher than those for rehydrated freeze-dried Kimchi.

Distribution of Sexually Transmitted Viral Diseases in Busan (부산지역 바이러스성 성병 감염양상 연구)

  • Cho, Kyung-Soon;Na, Young-Ran;Joe, Hyeon-Cheol;Lee, Jung-Hee;Jung, Myung-Ju
    • Korean Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.177-184
    • /
    • 2006
  • This study was performed to evaluate the prevalence of high risk Human papilloma virus (HPV), Herpes simplex virus type 1, 2 (HSV-1,2), Hepatitis B virus (HBV) and Human Immuno deficiency virus (HIV) infection with sexual transmitted viral diseases in Busan during 2004 to 2005. six hundred seventy four samples of cervical swabs were tested for sexually transmitted viral diseases. Among the isolated viruses, 23 (3.4%) samples were HPV and 3 (0.4%) and 9 (1.3%) samples were HSV 1 and 2, respectively. Among the 586 serum samples tested for viruses, HSV IgM 121 (3.6%), HSV-1 IgG 487 (83.1%), HSV-2 IgG 135 (23.0%), HBsAg 26 (4.4%), HBeAg 7 (1.2%), and HIV (0%) types were found. HPV genotypes were detected in 16 patients, of which 13 cases were high risk type HPV, 3 cases were low risk type HPV, and multi infection were detected in 7 cases. In the age distribution of the patients, 7.2% of infection tested from cervical swabs occurred in under the age of 20, while 100% of infection was found to occur in those who were 40 years old or older in the serum samples. The outbreak pattern in their occupations was found to be the highest at the health organization (amusement quarter) for the cervical swabs, and at infirmary (commercial sex worker) for the serum samples, respectively.

Quality Characteristics of Kimchi according to Garlic Content during Fermentation (마늘 첨가량에 따른 김치의 발효 중 품질 특성 변화)

  • Choi, Yun-Jeong;Hwang, Ye-Seul;Hong, Sung Wook;Lee, Mi-Ai
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1638-1648
    • /
    • 2016
  • This study was conducted to analyze the quality characteristics of kimchi in terms of garlic content (0~4.5%). Kimchi was made at $4^{\circ}C$ for 8 weeks, and pH, acidity, organic acid content, free sugar content, microbial counts, flavor pattern, and sensory characteristics were measured. The results show that kimchi containing garlic had a higher pH and lower acidity during fermentation than control kimchi without garlic. Principal component analysis enabled differentiation of the flavor pattern of kimchi according to fermentation period and garlic content. Addition of garlic to kimchi significantly decreased the numbers of total bacteria and lactic acid bacteria for 2 weeks after production. The numbers of total bacteria and lactic acid bacteria increased rapidly up to 2 weeks during fermentation and thereafter decreased gradually. Coliform counts were higher in the control than in kimchi containing garlic, whereas there was no detection after 4 weeks. Yeast and mold counts decreased significantly with increasing garlic content during the initial fermentation stage. Counts could not be detected in kimchi containing garlic. After 4 weeks, counts could not be detected in kimchi without garlic. Among kimchi with different garlic contents, fermentation was slower in kimchi with high garlic content; scores for off-odor and off-note taste were lower as well.

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.

Analysis of Magnetic Flux Leakage based Local Damage Detection Sensitivity According to Thickness of Steel Plate (누설자속 기반 강판 두께별 국부 손상 진단 감도 분석)

  • Kim, Ju-Won;Yu, Byoungjoon;Park, Sehwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • To diagnosis the local damages of the steel plates, magnetic flux leakage (MFL) method that is known as a adaptable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied in this study. To analysis the sensitivity according to thickness of steel plate in MFL method based damage diagnosis, several steel plate specimens that have different thickness were prepared and three depths of artificial damage were formed to the each specimens. To measured the MFL signals, a MFL sensor head that have a constant magnetization intensity were fabricated using a hall sensor and a magnetization yoke using permanent magnets. The magnetic flux signals obtained by using MFL sensor head were improved through a series of signal processing methods. The capability of local damage detection was verified from the measured MFL signals from each damage points. And, the peak to peak values (P-P value) extracted from the detected MFL signals from each thickness specimen were compared each other to analysis the MFL based local damage detection sensitivity according to the thickness of steel plate.

Comparative Analysis of the Flavor Compounds in Cultivated Chrysanthemum indicum L. (국내 육성 감국의 품종별 향기성분 비교 분석)

  • Oh, Kyeong Yeol;Goo, Young Min;Jeong, Won Min;Sin, Seung Mi;Kil, Young Sook;Ko, Keon Hee;Yang, Ki Jeung;Kim, Jin-Hyo;Lee, Dong Yeol
    • Journal of Life Science
    • /
    • v.28 no.12
    • /
    • pp.1523-1528
    • /
    • 2018
  • This study investigated the chemical composition of four Korean cultivated Chrysanthemum indicum L. (Gamguk 1 ho, Gamguk 2 ho, Gamguk 3 ho, and Wonhyang) which are used in the food and fragrance industries to identify their volatile flavor compounds. These compounds were analyzed using headspace GC-MS from plant samples cultivated in the same region of Korea (Sancheong-gun, Gyeongsangnam-do). A total of 23 compounds were identified, eight of which were common across the four cultivars. The major flavor components in the three Gamguk plants were identified as 3-carene, camphene, ${\beta}$-phellandrene, eucalyptol and (+)-camphor. Eleven compounds, including (+)-camphor at 31.40%, were identified in Gamguk 1 ho. Gamguk 2 ho was found to contain 12 flavor compounds, predominant of which was camphene at 25.60%. Thirteen compounds including (+)-camphor (26.88%) were identified in Gamguk 3 ho, while 17 were detected in the Wonhyang cultivar, including trans-piperitol (47.33%), sabinene, and ${\gamma}$-terpinyl acetate. These results indicate differences in the type and ratio of functional volatile flavor ingredients in Chrysanthemum indicum L. cultivars which is highly valuable as material for fragrance product development.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

Effective Defense Mechanism Against New Vulnerability Attacks (신규 취약점 공격에 대한 효율적인 방어 메커니즘)

  • Kwak, Young-Ok;Jo, In-June
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.499-506
    • /
    • 2021
  • Hackers' cyber attack techniques are becoming more sophisticated and diversified, with a form of attack that has never been seen before. In terms of information security vulnerability standard code (CVE), about 90,000 new codes were registered from 2015 to 2020. This indicates that security threats are increasing rapidly. When new security vulnerabilities occur, damage should be minimized by preparing countermeasures for them, but in many cases, companies are insufficient to cover the security management level and response system with a limited security IT budget. The reason is that it takes about a month for analysts to discover vulnerabilities through manual analysis, prepare countermeasures through security equipment, and patch security vulnerabilities. In the case of the public sector, the National Cyber Safety Center distributes and manages security operation policies in a batch. However, it is not easy to accept the security policy according to the characteristics of the manufacturer, and it takes about 3 weeks or more to verify the traffic for each section. In addition, when abnormal traffic inflow occurs, countermeasures such as detection and detection of infringement attacks through vulnerability analysis must be prepared, but there are limitations in response due to the absence of specialized security experts. In this paper, we proposed a method of using the security policy information sharing site "snort.org" to prepare effective countermeasures against new security vulnerability attacks.

Trends in Saliva Research and Biomedical Clinical Applications (타액 연구의 최신 지견과 임상 응용)

  • Soyoung Park;Eungyung Lee;Jonghyun Shin;Taesung Jeong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.1-12
    • /
    • 2023
  • Function of salivary gland and saliva composition can be an indicator of individual's health status. Recently, saliva has been thought to have a high potential for usage in the biomedical field to diagnose, evaluate, and prevent systemic health due to the technological advances in analyzing and detecting small elements such as immunological and metabolic products, viruses, microorganisms, hormones in saliva. As a diagnostic specimen, saliva has some useful advantages compared to serum. Because of simple non-invasive method, saliva sampling is quite comfort for the patient, and it doesn't require specialists to collect samples. The possibility of infection during the collection process is also low. For this reason, proteins, genetic materials, and various biomarkers in saliva are actively being utilized on studying stress, microbiomics, genetics, and epigenetics. For the research on collecting big data related to systemic health, the needs on biobank has been focused. Regeneration of salivary gland based on tissue engineering has been also on advancement. However, there are still many issues to be solved, such as the standardization of sample collection, storage, and usage. This review focuses on the recent trends in the field of saliva research and highlight the future perspectives in biomedical and other applications.

Simultaneous GC/MS Analyses of Organic acids and Amino acids in Urine using TMS-TFA derivative (TMS-TFA 유도체화를 이용한 소변여지 중 유기산과 아미노산의 GC/MS 동시분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.107-114
    • /
    • 2006
  • Early diagnosis and medical intervention are critical for the treatment of patients with metabolic disorders. A rapid analytical method was developed for simultaneous quantification of organic acids and amino acids in urine without labor-intensive pre-extraction procedure showing high sensitivity and specificity. A new method consisted of simple two-step trimethylsilyl (TMS)-trifluoroacetyl (TFA) derivatization using GC/MS-selective ion monitoring (SIM). Filter paper urine specimens were dried under nitrogen after being fortified with internal standard (tropate) in a mixture of distilled water and methanol. Methyl orange was added to the residue as indicator reagent. Silyl derivative of carboxylic functional group was followed by trifluoroacetyl derivative for amino functional group. N-methyl-N-(trimethylsilyl-trifluoroacetamide) and N-methyl-bistrifluoroacetamide were consecutively added and heated for 15-20 min at $65^{\circ}C-70^{\circ}C$, for TMS-TFA derivative, respectively. This reactant was analyzed by GC/MS-SIM. Linear dynamic range showed 0.001-50 mg with the detection limit of (S/N=3) 10-200 ng, and the quantification limit of 80-900 ng in urine. Correlation coefficient of regression line was 0.994-0.998. When the method was applied to the patients 'urine, it clearly differentiated the normal from the patient with metabolic disorder. The study showed that the developed method could be the method of choices in rapid and sensitive screening for organic aciduria and amino acidopathy.