• Title/Summary/Keyword: 검증연구

Search Result 32,342, Processing Time 0.102 seconds

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Genetic Relationship between Populations and Analysis of Genetic Structure in the Korean Native Chicken and the Endemic Chicken Breeds (한국재래닭 및 토착화 품종간의 유연 관계 및 유전 특성 분석)

  • Oh, J.D.;Kang, B.S.;Kim, H.K.;Park, M.N.;Chae, E.J.;Seo, O.S.;Lee, H.K.;Jeon, G.J.;Kong, H.S.
    • Korean Journal of Poultry Science
    • /
    • v.35 no.4
    • /
    • pp.361-366
    • /
    • 2009
  • The purpose of this study was to assess the genetic variation and establish the relationship amongst breeds and strains using 7 chicken specific microsatellite markers. A total of 317 DNA samples from four Korean native chicken (KNC) strains (KR: Korean Native Red chicken strain, KY: Korean Native Yellow chicken strain, KL: Korean Native Black chicken strain, KO: Ogol chicken strain) and three introduced endemic chicken breeds (LE: Leghorn chicken breed, RI: Rhode Island Red chicken breed, CO: Cornish chicken breed). The size of microsatellite markers was decided using GeneMapper Software (v.4.0) after being analyzed using an ABI 3130 Genetic Analyzer. Frequencies of microsatellites markers were used to estimate heterozygosities and genetic distances. The lowest distance (0.074) was observed between the KY and KL breeds and the highest distance (0.779) between the KL and LE breeds. The KNC strains (KR, KY, KL) have comparatively near genetic distance each other. On the other side, each individual was not ramified to different groups and were spread evenly in phylogenetic dendrogram about all the KNC of each strain populations. But the endemic breed populations (LE, RI, CO) were ramified to different groups. The microsatellite polymorphism data were shown to be useful for assessing the genetic relationship between Korean native strains and other foreign breeds.

Optimization of in vitro lily culture system with different treatments of taurine (타우린 처리에 의한 나리 기내 식물체 생산체계 최적화)

  • Lee, Sang-Hee;Yang, Hwan-Rae;Kim, Sun Tae;Jun, Tae Hwan;Kim, Yong Chul;Kim, Jong Bo
    • Journal of Plant Biotechnology
    • /
    • v.44 no.4
    • /
    • pp.484-489
    • /
    • 2017
  • Lilies as cut flowers are one of the most popular ornamental plants in South Korea. It is necessary to develop lily cultivars with high qualities. Therefore, highly efficient propagation systems are needed following release of elite cultivars. In this study, we used taurine treatment to improve the growth conditions including shoot and bulb formation, fresh weight gain, and reduction of rooting and browning. We experimentally evaluated the effect of taurine as a growth stimulator, at concentrations of 0, 2.5, 5, 10, 15 and 20 mg/l. The results showed that 20 mg of taurine enhanced shoot formation by 85% and increased fresh weight 5.5-fold, which was higher than the approximately four-fold increase in the control. In addition, multiple bulb formation rate was increased by 80% and rooting by 82% following exposure to 20 mg/l of taurine. The efficiency of taurine treatment was higher than that of control with 50% multiple bulb formation rate and 60% rooting rate. The browning was 10.6% at 2.5 mg/l of taurine when compared with 0.8% at 20 mg/l. Taurine showed a positive effect on the overall growth of lily plants in terms of increased fresh weight, shoot formation rate, rooting, and formation of multiple bulbs, indicating that taurine can be used as an alternative to amino acids or as an antioxidant such as citrate and vitamin C in plant tissue culture.

Seismic Design of Columns in Inverted V-braced Steel Frames Considering Brace Buckling (가새좌굴을 고려한 역 V형 가새골조의 기둥부재 내진설계법)

  • Cho, Chun-Hee;Kim, Jung-Jae;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • According to the capacity design concept which forms the basis of the current steel seismic codes, the braces in concentrically braced frames (CBFs) should dissipate seismic energy through cyclic tension yielding and cyclic compression buckling while the beams and the columns should remain elastic. Brace buckling in inverted V-braced frames induces unbalanced vertical forces which, in turn, impose the additional beam moments and column axial forces. However, due to difficulty in predicting the location of buckling stories, the most conservative approach implied in the design code is to estimate the column axial forces by adding all the unbalanced vertical forces in the upper stories. One alternative approach, less conservative and recommended by the current code, is to estimate the column axial forces based on the amplified seismic load expected at the mechanism-level response. Both are either too conservative or lacking technical foundation. In this paper, three combination rules for a rational estimation of the column axial forces were proposed. The idea central to the three methods is to detect the stories of high buckling potential based on pushover analysis and dynamic behavior. The unbalanced vertical forces in the stories detected as high buckling potential are summed in a linear manner while those in other stories are combined by following the SRSS(square root of sum of squares) rule. The accuracy and design advantage of the three methods were validated by comparing extensive inelastic dynamic analysis results. The mode-shape based method(MSBM), which is both simple and accurate, is recommended as the method of choice for practicing engineers among the three.

Estimation of Soil Surface Temperature by Heat Flux in Soil (Heat flux를 이용한 토양 표면 온도 예측)

  • Hur, Seung-Oh;Kim, Won-Tae;Jung, Kang-Ho;Ha, Sang-Keon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.3
    • /
    • pp.131-135
    • /
    • 2004
  • This study was carried out for the analysis of temperature characteristics on soil surface using soil heat flux which is one of the important parameters forming soil temperature. Soil surface temperature was estimated by using the soil temperature measured at 10 cm soil depth and the soil heat flux measured by flux plate at 5 cm soil depth. There was time lag of two hours between soil temperature and soil heat flux. Temperature changes over time showed a positive correlation with soil heat flux. Soil surface temperature was estimated by the equation using variable separation method for soil surface temperature. Arithmetic mean using temperatures measured at soil surface and 10 cm depth, and soil temperature measured at 5 cm depth were compared for accuracy of the value. To validate the regression model through this comparison, F-validation was used. Usefulness of deductive regression model was admitted because intended F-value was smaller than 0.001 and the determination coefficient was 0.968. It can be concluded that the estimated surface soil temperatures obtained by variable separation method were almost equal to the measured surface soil temperature.

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

Successful 20 hours Canine Allograft Preservation with new Solution Containing Triiodothyronine - Development of new lung preservation solution II - (삼요드티로닌을 포함한 폐보존액을 이용한 20시간 폐보존 - 새로운 폐 보존액의 개발 II -)

  • 성숙환;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.413-421
    • /
    • 1999
  • Background: Ischemia reperfusion injury is known to contribute to the major causes of the early graft failure in lung transplantation. Triiodothyronine (T3) has been suggested to ameliorate ischemia reperfusion injury from both in vivo and in vitro experiments of various organs. Prospecting its beneficial effect for pulmonary allograft preservation, we made a new solution by adding T3 into the extracellular type dextran solution. Material and Method: Twelve adult mongrel dogs underwent left lung allotransplantation. Six donor dogs were flushed with the new solution(Group 1, n=6), and the remaining six were flushed with Euro-Collins solution to serve as controls(Group 2, n=6). Allografts were stored in each preservation solution for 20 hours at 4$^{\circ}C$. Left single lung transplantations were performed. The right pulmonary artery and the right main bronchus were clamped at 15 minutes after the reperfusion and maintained throughout the experiment to evaluate the transplanted left lung function. Result: Arterial carbon dioxide tension was better in group 1 than in group 2 throughout the experiment period and the difference was statistically significant at 2 hours after reperfusion(28.0${\pm}$3.0 mmHg and 53.1${\pm}$17.4 mmHg, p<0.05). The differences of arterial oxygen partial pressure, peak airway pressure and pulmonary vascular resistance showed no statistical significance. The malondialdehyde(MDA) level, measured from tissue obtained at 120 minutes after reperfusion showed no statistically significant difference. The tissue wet/dry ratio of group 1(649${\pm}$27 %) was significantly lower than that of group 2(686${\pm}$71 %, p<0.05). The microscopic examination revealed varying degrees of injury represented mainly by findings such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. These findings were less severe in group 1 than those in group 2. Conclusion: The new solution demonstrated superior allograft preservation after 20 hour ischemia compared to Euro-Collins solution in canine single left lung transplantation model, these results suggest that T3 might be a promising agent for pulmonary allograft preservation.

  • PDF

Comparative Analysis of SWAT Generated Streamflow and Stream Water Quality Using Different Spatial Resolution Data (SWAT모형에서 공간 입력자료의 다양한 해상도에 따른 수문-수질 모의결과의 비교분석)

  • Park, Jong-Yoon;Lee, Mi-Seon;Park, Geun-Ae;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.11
    • /
    • pp.1079-1094
    • /
    • 2008
  • This study is to evaluate the impact of varying spatial resolutions on the uncertainty of Soil and Water Assessment Tool (SWAT) predicted streamflow, non-point source (NPS) pollution loads transport in a small agricultural watershed (1.21 $km^2$) for three cases of model input; Case A is the combination of 2 m DEM, QuickBird land use, Case B is the combination of 10 m DEM, 1/25,000 land use, and Case C is the combination of 30 m DEM, Landsat land use, soil data is used 1/25,000 for three cases respectively. The model was calibrated for 2 years (1999-2000) using daily streamflow and monthly water quality records, and verified for another 2 years (2001-2002). The average Nash and Sutcliffe model efficiency was 0.59 for streamflow and RMSE were 2.08, 4.30 and 0.70 tons/yr for sediment, T-N and T-P respectively. The model was run for a small agricultural watershed with three cases of spatial input data. The hydrological results showed that output uncertainty was biggest by spatial resolution of land use. Streamflow increase the watershed average CN value of QucikBird land use was 0.4 and 1.8 higher than those of 1/25,000 and Landsat land use caused increase of streamflow. On the other hand, The NPS loadings from the model prediction showed that the sediment, T-N and T-P of QuickBird land use (Case A) showed 23.7 %, 43.3 % and 48.4 % higher value than 1/25,000 land use (Case B) and 50.6 %, 50.8 % and 56.9 % higher value than Landsat land use (Case C) respectively.

Screening of 94 Plant Species Showing ACE Inhibitory Activity (식물자원으로부터 Angiotensin Converting Enzyme 저해활성 탐색)

  • Yun, Jeong-Sik;Chung, Byung-Hee;Kim, Na-Young;Seong, Nak-Sul;Lee, Hyeon-Yong;Lee, Jin-Ha;Kim, Jong-Dai
    • Korean Journal of Medicinal Crop Science
    • /
    • v.11 no.3
    • /
    • pp.246-251
    • /
    • 2003
  • Angiotensin converting enzyme(ACE) belongs to the class of zinc protease and plays an important role in the regulation of blood pressure. In this experiment, we investigated the inhibitory activities of ninety four plant extracts on ACE. The extracts were prepared by water and refluxing with 70% and 100% methanol. Among the extracts, two plant extracts such as Cassia tora, Persicaria cochinchinensis Kitagawa showed more than 60% inhibitory activities, and Foeniculum vulgare Gaertner, Scutellaria baicalensis Georgl, Caragana sinica (Buchoz) Rehder, Inula britannica var. chinensis showed $45.2{\sim}49.7%$ inhibitory activities. Twenty eight plant extracts such as Hemerocallis fulva L, Camptotheca acuminata Decne, Inula britannica var. chinensis, Xanthium strumarium, Polygonatum odoratum, Phellodendron amurense Rupr, Coix lachryma-jobi var. mayuen, Prunus ansu, Hibiscus mutabilis L, Thchosanthes kirilowii, Helianthus annuus, Juglans sinensis showed $30.3{\sim}39.7%$ Inhibitory activities. These results suggest that plant extracts which contain high ACE inhibitory activities may be useful as anti-hypertension agents and to the treatment of hypertension.

A Simultaneously Analytical Method of Phthalate and Adipate Plasticizers in Food Packaging by Dual-Column GC-FID System (Dual-Column GC-FID System을 이용한 식품 포장재 중 Phthalate류 및 Adipate류 가소제의 동시 분석법)

  • Kang Gil-Jin;Kwak In-Shin;Eom Mi-Ok;Jeon Dea-Hoon;Kim Hyung-il;Sung Jun-Hyun;Choi Jung-Mi;Kim Eun-Kyung;Lee Young Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.277-283
    • /
    • 2005
  • A plasticizer is a substance which is added to a material to improve its processability, flexibility and stratchability. Phthalates and adipates are the most frequently used plasticizers of poly(vinyl chloride) (PVC). However, they can migtate into food from PVC food packaging, and some of them are especially suspected as endocrine disruptors. In this study, Simultaneous analysis of 13 phthalates and 9 adipates were carried out by dual-column gas chromatography system equipped wi two FID detectors for rapid confirmation and quantification. The Proposed method was validated with > 0.993 of linearity in the ranges of 10-500 mg/l, < $3.5\%$ RSD of reproducability in 10 inter-days sample preparations, and > $98.1\%$ of recoveries for all the plasticizers. DEHA was detected in all the 3 PVC wraps at levels of 176.9-198.5mg/g. Among the 51 samples of PVC gaskets, the targeted plasticizers were detected in 41 samples. Of these plasticizer detected samples,40 contained DIDP at the levels of 157.3-374.7 mg/g and one contained DMP at the levels of 165.6 mg/g. Also, some plasticizers were detected in other packaging materials such as PET, PP, PE, Pulp. But it might be attributed to contamination in manufacturing.