• Title/Summary/Keyword: 검증시험

Search Result 4,367, Processing Time 0.042 seconds

Estimation Method of Resilience Pads Spring Stiffness for Sleeper Floating Tracks based on Track Vibration (궤도 진동기반의 침목플로팅궤도 침목방진패드 스프링강성 추정 기법 연구)

  • Jung-Youl Choi;Sang-Wook Park;Jee-Seung Chung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.1057-1063
    • /
    • 2023
  • The urban railway sleeper floating track, the subject of this study, is an anti-vibration track to reduce vibration transmitted to the structure. currently, the replacement cycle of resilience pad for sleeper floating tracks is set and operated based on load. however, most previous studies were conducted on load-based structural safety aspects, such as fatigue life evaluation of sleeper anti-vibration pads and increase in track impact coefficient and track support stiffness due to increase in spring stiffness. therefore, in this study, we measure the vibration acceleration of the ballast for each analysis section and use the results of 7 million fatigue tests to calculate the spring stiffness of the resilience pad for each section. the spring stiffness of the resilience pad calculated for each section was set as the analysis data and the concrete vibration acceleration was derived analytically. the adequacy of analysis modeling was verified as the analyzed concrete bed vibration acceleration for each section was within the field-measured concrete bed vibration acceleration range. using the vibration acceleration curve according to the derived spring stiffness change, the spring stiffness of the resilience pad is estimated from the measured vibration acceleration. therefore, we would like to present a technique that can estimate the spring stiffness of resilience pad of a running track using the vibration acceleration of the measured concrete bed.

Application of Eddy Current Sensor for Measurement of TBM Disc Cutter Wear (TBM 디스크커터의 마모량 측정을 위한 와전류센서의 적용 연구)

  • Min-Sung Park;Min-Seok Ju;Jung-Joo Kim;Hoyoung Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.534-546
    • /
    • 2023
  • If the disc cutter is excessively worn or damaged, it becomes incapable of rotating and efficiently cutting rockmass. Therefore, it is important to appropriately manage the replacement cycle of the disc cutter based on its degree of wear. In general, the replacement cycle is determined based on the results of manual inspection. However, the manual measurements has issues related to worker safety and may lead to inaccurate measurement results. For these reasons, some foreign countries are developing the real-time measurement system of disc cutter wear by using different sensors. The ultrasonic sensors, eddy current sensors, magnetic sensors, and others are utilized for measuring the wear amount of disc cutters. In this study, the applicability of eddy current sensors for real-time measurement of wear amount in TBM disc cutters was evaluated. The distance measurement accuracy of the eddy current sensor was assessed through laboratory tests. In particular, the accuracy of eddy-current sensor was evaluated in various environmental conditions within the cutterhead chamber. In addition, the measurement accuracy of the eddy current sensor was validated using a 17-inch disc cutter.

A Study on LNG Quality Analysis using a Raman Analyzer (라만분석기를 이용한 LNG 품질 분석 실증 연구)

  • Kang-Jin Lee;Woo-Sung Ju;Yoo-Jin Go;Yong-Gi Mo;Seung-Ho Lee;Yoeung-Chul Kim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.70-79
    • /
    • 2024
  • Raman analyzer is an analytical technique that utilizes the "Raman effect", which occurs when light is scattered by the inherent vibrations of molecules. It is used for molecular identification and composition analysis. In the natural gas industry, it is widely used in bunkering and tank lorry fields in addition to LNG export and import terminals. In this study, a LNG-specific Raman analyzer was installed and operated under actual field conditions to analyze the composition and principal properties (calorific value, reference density, etc.) of LNG. The measured LNG composition and calorific value were compared with those obtained by conventional gas chromatograph that are currently in operation and validated. The test results showed that the Raman analyzer provided rapid and stable measurements of LNG composition and calorific value. When comparing the calorific value, which serves as the basis for LNG transactions, with the results from conventional gas chromatograph, the Raman analyzer met the acceptable error criteria. Furthermore, the measurement results obtained in this study satisfied the accuracy criteria of relevant international standards (ASTM D7940-14) and demonstrated similar outcomes compared to large-scale international demonstration cases.

Review of In-situ Installation of Buffer and Backfill and Their Water Saturation Management for a Deep Geological Disposal System of Spent Nuclear Fuel (국외 사례를 통한 사용후핵연료 심층처분시스템 완충재 및 뒤채움재의 현장시공 및 포화도 관리 기술 분석)

  • Ju-Won Yun;Won-Jin Cho;Hyung-Mok Kim
    • Tunnel and Underground Space
    • /
    • v.34 no.2
    • /
    • pp.104-126
    • /
    • 2024
  • Buffer and backfill play an essential role in isolating high-level radioactive waste and retard the migration of leaked radionuclides in deep geological disposal system. A bentonite mixture, which exhibits a swelling property, is considered for buffer and backfill materials, and excessive groundwater inflow from surrounding rock mass may affect stability and efficiency of their role as an engineered barrier. Therefore, stringent quality control as well as in-situ installation management and inflow water constrol for buffer and backfill are required to ensure the safety of deep disposal facilities. In this study, we analyzed the design requirements of buffer and backfill by examining various laboratory tests and a field study of the Steel Tunnel Test at the Äspö Hard Rock Laboratory in Sweden. We introduced how to control the quality of buffer and backfill construction in-field, and also presented how to handle excessive groundwater inflow into disposal caverns, validating the groundwater retention capacity of bentonite pellets and the effectiveness of geotexile use.

Manufacture and Qualification of Composite Main Reflector of High Stable Deployable Antenna for Satellite (위성용 전개형 고안정 반사판 안테나 주반사판 제작 및 검증)

  • Dong-Geon Kim;Hyun-Guk Kim;Dong-Yeon Kim;Kyung-Rae Koo;Ji-min An;O-young Choi
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.219-225
    • /
    • 2024
  • It is essential to develop a light-weight, high-performance structure for the deployable reflector antenna, which is the payload of a reconnaissance satellite, considering launch and orbital operation performance. Among them, the composite main reflector is a key component that constitutes a deployable reflector antenna. In particular, the development of a high-performance main reflector is required to acquire high-quality satellite images after agile attitude control maneuvers during satellite missions. To develop main reflector, the initial design of the main reflector was confirmed considering the structural performance according to the laminate stacking design and material properties of the composite main reflector that constitutes the deployable reflector antenna. Based on the initial design, four types of composite main reflectors were manufactured with the variable for manufacturing process. As variables for manufacturing process, the curing process of the composite structure, the application of adhesive film between the carbon fiber composite sheet and the honeycomb core, and the venting path inside the sandwich composite were selected. After manufacture main reflector, weight measurement, non-destructive testing(NDT), surface error measurement, and modal test were performed on the four types of main reflectors produced. By selecting a manufacturing process that does not apply adhesive film and includes venting path, for a composite main reflector with light weight and structural performance, we developed and verified a main reflector that can be applied to the SAR(Synthetic Aperture Rader) satellite.

Development of Radar System for Laser Tracking System (레이저 추적 시스템을 위한 레이더 시스템 개발)

  • Ki-Pyoung Sung;Hyung-Chul Lim;Man-Soo Choi;Sung-Yeol Yu
    • Journal of Space Technology and Applications
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Korea Astronomy and Space Science Institute (KASI) developed an satellite laser ranging (SLR) system for tracking space objects using ultra-pulsed lasers. For the safe operation of SLR system, aircraft surveillance radar system (ASRS) was developed to prevent human damage from high power laser transmitted from the SLR system. The ASRS consists of the radar hardware subsystem (RHS) and main control subsystem (MCS), in order to detect flying objects in the direction of laser propagation and then stop immediately the laser transmission. The RHS transmits the radio frequency (RF) pulse signals and receives the returned signals, while the MCS analyzes the characteristics of received signals and distinguishes the existence of flying objects. If the flying objects are determined to be existed, the MCS sends the command signal to the laser controller in SLR system to pause the laser firing. In this study, we address the interface and operational scenarios of ASRS, including the design of RHS and MCS. It was demonstrated in the aircraft experiments that the ASRS could detect an aircraft and then stop transmitting high power laser successfully.

Non-clinical Trials using 14C-Acetaminophen to Validate Biomedical Accelerator Mass Spectrometry System (14C-아세트아미노펜 비임상시험을 통한 생체시료 분석용 가속질량분석기의 검증)

  • Jinho Song;Jae Hoon Shim;Jung Bae Park;Chang Su Yeo;Soo Hyeon Bae;Min Sun Choi;Mi Hye Kwon;Kyeong Min Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2023
  • Pharmacokinetic (PK) data provide pivotal information in drug development, and they are usually first studied in the preclinical stage using various animals. However, quite often, animal PK data may not match with human PK, especially in metabolites. Thus, most regulatory agencies in the world make it mandatory to obtain metabolite information using 14C radiolabeled drug in human for small molecule drug candidates. However, such studies are expensive and time consuming and they are usually done at the end of Phase II trials using ~3.7 MBq of 14C labeled drug in a limited number of human subjects. Introduction of accelerator mass spectrometry (AMS) in this kind of study has revolutionized it. Since AMS can measure 14C level as close as natural abundance, it can quantify the amounts of 14C labeled drugs and their metabolites produced in human body that consumes less than the amount of 0.0037 MBq of 14C labeled drug, a very safe level of radioactive dose in human. Therefore, it is now possible to conduct human 14C studies safely in early clinical trials without spending hefty amount of money and time. Korea Radioisotope Center for Pharmaceuticals(KRICP) at Korea Institute of Biological and Medical Sciences(KIRAMS) has established an AMS facility in 2018, housing a 0.5MV AMS manufactured at the US National Electrostatics Corps (NEC). The AMS instrument has been validated using various standard samples that have been prepared at Lawrence Livermore National Laboratory in the US, a worldly reputable provider of AMS standards. In this paper, we present a mass balance study for acetaminophen in rats using AMS and prove that the study results are equivalent with those of literature, which shows the AMS facilities at KRICP has successfully installed and be ready to be used in the various PK studies using 14C labelled compounds for new drug development.

Pomegranate Extract Improves Menopausal Syndrome in Ovariectomized Rats (난소 적출 동물모델에서 고흥산 석류 농축액의 갱년기 증상 개선 효과)

  • Wee, Ji-Hyang;Jung, Hyun Jung;Jung, Kyung Ok;Sung, Hea Mi;Shin, Yu-Rim;Park, Ju-Hyun;Seo, Hyeon-Young;Lim, Jung-Min;Chae, Han-Jeong;Lee, Ki Yung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.4
    • /
    • pp.506-515
    • /
    • 2015
  • In this study, the effect of Goheung pomegranate extract on postmenopausal syndrome was evaluated both in vitro and in vivo in ovariectomized Sprague-Dawly (SD) rats. Sixty female SD rats were divided into six groups: sham, sham operation and distilled water; OVX, ovariectomized and distilled water; PE1, ovariectomized and pomegranate concentrate (0.75 mL/twice/d); PE2, ovariectomized and pomegranate concentrate (1.5 mL/twice/d); PE3, ovariectomized and pomegranate concentrate (2.2 mL/twice/d); and CE, ovariectomized and commercial pomegranate concentrate (2.2 mL/twice/d). Percent bone volume (bone volume/tissue volume) and trabecular thickness (Tb.Th) improved in a dose-independent manner in PE1, 2, and 3. Especially, bone mineral density was significantly improved in PE3 (P<0.05) compared to OVX. Pomegranate extract reduced body weight and visceral fat mass. High density lipoprotein cholesterol (HDL-C) level slightly increased in a dose-independent manner in the experimental group. In addition, HDL-C/total cholesterol level of PE3 significantly increased (P<0.05) compared with OVX. These results show that pomegranate concentrate improved blood lipid levels and bone metabolism in ovariectomized rats. Therefore, Goheung pomegranate concentrates are expected to improve cardiovascular and bone-related diseases in menopausal women.

A Study on the Actual Conditions of and Satisfaction with the Existed Female Dress Forms Usage (국내 여성용 인대 사용 실태 및 만족도에 관한 연구)

  • Park Gin-Ah;Lee Hye-Young;Choi Jin-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.3 s.151
    • /
    • pp.378-385
    • /
    • 2006
  • To release fashion trends in an efficient way, many of the apparel business and fashion educational institutes in land adopt fashion shows employing fashion models. Modeling rather than flat pattern making realizes the majority of the complicated design works for the fashion shows. However, for the different measurements between the dress form and the real human model, problems often occur during the modeling and fitting processes. Researches on the standard dress form development representing professional fashion models' features are therefore in urgent need to enable the related apparel business and fashion institutes to make appropriate use of the dress form in their jobs. The study has been conducted as a preliminary study using a questionnaire method ultimately to develop the female dress form. A questionnaire in the research aimed at an investigation into the actual conditions of and satisfaction with the usage and the body measurements of existed dress forms. Approximately 30 fashion-related educational institutes and 10 apparel companies responded to the survey. Data derived from the survey was analyzed using SPSS version 10.1, the statistics tool. The results throughout the research were discussed in terms of largely three categories that are; (1) the general conditions of the usage of the dress form to prepare fashion shows: e.g. the frequency of holding the fashion show in an annual term, the proportion of professional and amateur models employed for the fashion show, the methods to construct garments, types and number of dress forms utilized and etc.; (2) factors considered to purchase the dress form e.g. its functionality, shapes, sizes, duration, price, A/S condition and etc.; and(3) satisfaction with the similarity between the dress form and the human body in the relation to the body measurements. Measurements in length wise, front and back waist lengths, neck to bust point on the dress forms were apparently differed from the ones of the actual body. In particular, differed torso length measurements cause the problem to have to alter the whole silhouette, consequently, the resultant patterns as well. In girth measurements, in order of bust and waist girths, the satisfaction was low.

Optimization of Analytical Methods for Octacosanol in Related Health-functional Foods with GC-MS (GC-MS를 이용한 건강기능식품 중 옥타코사놀 분석법 개발 연구)

  • Lee, Jin Hee;Oh, Mi Hyune;Lee, Kyung Jin;Kim, Yang Sun;Keum, Eun Hee;Park, Ji Eun;Cho, Mee Hyun;Seong, Min Hye;Kim, Sang A;Kim, Mee hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for health-functional foods (dietary food supplements) to establish regulatory standards and specifications in Korea. In this regard, we continue our research on developing analytical methods for the items. Octacosanol is the major component of polycosanol and is a high-molecular-mass primary fatty alcohol, obtained from sugar cane wax. Previous researchers have shown that octacosanol can lower cholesterol and has antiaggregatory properties, cytoprotective uses, and ergogenic properties for human health. Recently, octacosanol products have been actively introduced into the domestic market because of their functional biological activity. We have developed a sensitive and selective test method for octacosanol that the TMS derivatives by means of gas-chromatographic-tandem mass spectrometry (GC-MS). The trimethylsilyl ether derivative of the target analyte showed excellent chromatographic properties. The procedure was validated in the range of $12.5{\sim}200{\mu}g/L$. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.999, and the limits of detection (LOD) and limits of quantitation (LOQ) were $4.5{\mu}g/L$ and $13.8{\mu}g/L$, respectively. The high recoveries (92.5 to 108.8%) and precision (1.8 to 2.4%) obtained are in accordance with the established validation criteria. Our research can provide scientific evidence to amend the octacosanol test method for the Health-Functional Food Code.