• Title/Summary/Keyword: 검사 장치

Search Result 1,054, Processing Time 0.032 seconds

The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test (디지털 X선 촬영장치의 한계 검사 개선 및 유용성 평가)

  • Gil, Jong-Won;Park, Jeong-Ho;Bae, Seok-Hwan;Hwang, Hye-Jeong;Kim, Yong-Gwon
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.371-379
    • /
    • 2014
  • In this study, we conducted a survey on the limited examinations of the DR system to the 30 radiologic technologists engaging in the clinical sites and university hospitals in Daejeon metropolitan city from Oct. 15, 2012 to Nov. 15, 2012. Based on the survey results, we propose the conceptual design of a supplementary table for the conventional DR system to extend the examination capability and overcome the limitation of DR system. And, we evaluated the convenience and usefulness of the proposed table by applying it to five subjects. Ten experts were involved to evaluate the clinical usefulness of the obtained images. In this study, the experimental results show the feasibility to overcome the limited examination of the conventional DR system, and the proposed supplementary table may be beneficial to patients and hospitals.

Study on the 3D Assembly Inspection of Two-Step Variable Valve Lift Modules Using Laser-Vision Technology (레이저 비전을 이용한 2단 가변밸브 리프트 모듈의 3D 조립검사에 대한 연구)

  • Nguyen, Huu-Cuong;Kim, Do-Joong;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.949-957
    • /
    • 2017
  • A laser-vision-based height measurement system is developed and implemented for the inspection of two-step variable valve lift module assemblies. The proposed laser-vision sensor module is designed based on the principle of laser triangulation. This paper summarizes the work on 3D point cloud data collection and height difference measurements. The configuration of the measurement system and the proposed height measurement algorithm are described and analyzed in detail. Additional measurement experiments on the height differences of valves and lash adjusters of a two-step variable valve lift module were implemented repeatedly to evaluate the accuracy and repeatability of the proposed measurement system. Experimental results show that the proposed laser-vision-based height measurement system achieves high accuracy, repeatability, and stabilization for the inspection of two-step variable valve lift module assemblies.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

LED frame inspection system design and implementation (LED 프레임 검사 시스템 설계 및 구현)

  • Park, Byung-Joon;Kim, Sun-jib
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.359-363
    • /
    • 2017
  • The LED (Liquid Emitting Diode) frame device is a big part of the representative display industry in Korea. LED is an essential part for TV, monitor, notebook, and mobile phone. In Japan, Taiwan, China and other countries, investment in LEDs has been strengthened, and productivity has become an important issue. However, as the size of the parts becomes smaller, the inconsistent inspection by the human eye becomes a problem of reliability, so that the automatic inspection process becomes an essential issue in the field of LED module inspection. In this paper, we investigate defects in visual inspection process using computer vision technology. The inspection of the LED frame is made quickly and accurately, thereby improving the efficiency of the process and shortening the inspection time. As a result of applying the inspection system to the field, we confirmed that it is possible to inspect quickly and accurately.

An ability test for the use of indirect radiographic unit (간접촬영용 X-선 발생장치 성능 평가)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.37-41
    • /
    • 2004
  • Purpose : Raise ability cultivation in presence at a sicked business by performance management estimation of device through measurement. Also Learn a technology that measure exact tube voltage, exposure time, output dose. And it is to grasp photofluorography X-ray generator existing circumstances using at hospital. Material & Method : Investigated Photofluorography X-ray generator(inside, outside each 10) of 10 university hospitals using tube voltage, exposure time, output dose measuring instrument. Result : Photofluorography device that tube voltage correctness is incongruent by examination PAE decision came out 3, and at exposure time correctness examination 2 incongruent, Also 3 that calculate coefficient of variation about exposure in repeatability examination of exposure were incongruent. Inappropriate photofluorography device is 5 outside hospital(mobile unit) and the thing in hospital was 3 in 3 kind of efficiency test. It appeared high that photofluorography device outside hospital is more incongruent than thing in hospital. Conclusion : May ready situation that can offer patient medical service of good quality by radiation exposure reduction, image quality administration, retake decrease etc. by keeping performance of Photofluorography device. Therefore, is considered that need on-time efficiency test.

  • PDF

Study for Development of Nondestructive Inspection Device in Natural Gas Pipeline Using MFL Technology (MFL을 이용한 천연가스 배관용 비파괴 검사장비 개발에 관한 연구)

  • Cho S.H.;Kim D.K.;Park D.J.;Park S.S.;Yoo H.R.;Koo S.J.;Rho Y.W.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.10-16
    • /
    • 2002
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

Effect of Occlusal Stabilizing Splint for Osteoarthritis of Temporomandibular Joint (측두하악관절의 골관절염에 대한 교합안정장치의 치료효과)

  • Kim, Ji-Hyun;Jeon, Hye-Mi;Ok, Soo-Min;Heo, Jun-Young;Jeong, Jung-Hee;Ahn, Young-Woo;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.2
    • /
    • pp.113-123
    • /
    • 2012
  • To evaluate the treatment outcome of occlusal stabilizing splint in patients with TMJ osteoarthritis, the 76 subjects were chosen among the patients who presented to the Department of Oral medicine of Pusan National University Hospital, diagnosed as TMJ osteoarthritis by cone beam computed tomography, x-ray and clinical exam, and treated with occlusal stabilizing splint from 2009 to 2011. They were treated with physical therapy and medication before occlusal stabilizing splint delivery and checked monthly after occlusal stabilizing splint delivery. Subjective symptoms and clinical findings were investigated to evaluate and compare the subjects' status at the first visit, splint delivery visit and the last visit. The results were as follows; 1. Pain, noise, LOM and MCO were significantly improved between the first visit and occlusal stabilizing splint delivery visit, and between occlusal stabilizing splint delivery and the last visit. 2. In the acute group, pain and noise were significantly improved between the first visit and occlusal stabilizing splint delivery visit. Pain, LOM and MCO were significantly improved between splint delivery visit and the last visit 3. In the chronic group, pain, noise and LOM were significantly improved between occlusal stabilizing splint delivery visit and the last visit.

A Development of on Auto Inspection System for Automotive Valve-Seal using Standalone Vision (독립형 비전을 이용한 자동차용 Valve-Seal의 자동 검사시스템 개발)

  • Lee, Kyu-Hun;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.71-80
    • /
    • 2007
  • In this study, an inspection system for valve seal of automotive parts using standalone vision has been developed and presented. The system is comprised of eight CCD cameras, and mechanism that loads the automotive parts to the system for the inspection. An image processing algorithm for detecting two different types of defects of valve seals are developed and the effectiveness of the algorithm is experimentally verified. Inspection process is completed in 0.7 second with acceptable accuracy condition. It is envisaged that this inspection system will have a wide application in the automotive part manufacturing industry in the future.

All goods Inspection Convergence System for the Development of LCD Molybdenum Pin (LCD 몰리브덴 핀 개발을 위한 전수검사 융합시스템)

  • Lee, Jeongl-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.183-187
    • /
    • 2020
  • The molybdenum cup and molybdenum pin, which are the main materials of the molybdenum electrode used for the LCD BLU CCFL electrode, have not been developed in Japan and all of them are imported and used from Japan, is giving a competitive burden. In this research, to develop the manufacturing technology of molybdenum pin used for CCFL electrode of LCD BLU, development of linear processing technology, development of molybdenum wire surface treatment technology, development of wire cutting technology, production of molybdenum pin, design and fabrication of JIG and Fixture for inspection, molybdenum pin prototyping and analysis, and development of 100% molybdenum pin inspection technology. In this paper, especially, In this paper, especially, research on the convergency design for total inspection machine is treated. is treated.

Research and Development of Electrode Surface Inspection System (전극 표면 검사 장치 연구 개발)

  • Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.123-128
    • /
    • 2016
  • In manufacturing processing of a secondary battery, the visual inspection system is studied and developed to check the surface defects of the electrode plates. It consists of two parts, one is the hardware control and the other software implementation. The former is made up to the system configuration and the design of the optical system, the illuminations and the controllers. The latter is the detection algorithms of the surface defects. This system achieves the quality improvement of the electrode process and the price competitiveness. By using the proposed defects detection algorithms this system demonstrates the high reliability of spot, line, manhole, extraneous substance, scratch, and crater defect of a electrode plate surface.