• Title/Summary/Keyword: 검사 장비

Search Result 987, Processing Time 0.037 seconds

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

A Study on the Improvement of Performance Testing System of Domestic Surveying Equipment (국내 측량장비 성능검사제도 개선방안 연구)

  • MIN, Kwan-Sik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.53-63
    • /
    • 2016
  • In this paper, we proposed the improvements for performance test and surveying equipment regulations, standards, methods and procedures, depending on the need of improving the legal system for surveying equipment in a diverse and sophisticated surveying industry. This research was performed first investigating the existing legal systems(Act on the establishment and management of spatial data, Framework act on national standards, ISO 17123, JIS B 7912) with respect to the surveying equipment performance testing and the research for IOS and KOLAS suggested the improvements on the application for the surveying equipment performance testing standard. More exactly, first, two years were presented for the surveying equipment performance testing cycle considering the precise accuracy of the instrument stability, purpose and frequency of use, etc. Second, the abolition of the measurement distance by grade and the upward or cross-grade adjustment of the single prism standards about the light wave rangefinder and total station were suggested for the improvement on survey equipment performance criteria. Third, since the main function of total station is focused on a three-dimensional coordinate measurement due to the improvement of surveying equipment performance testing, it was proposed to use the precision(repeatability) of the coordinate measuring method as an evaluation method.

Safeguards Approach for the Verification of both Dry Canister and Transfer Campaign (건식저장고 및 Transfer Campaign에 대한 국가 계량관리 검사 접근방법)

  • 이재성;차흥렬;박완수;윤여창
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1997.10a
    • /
    • pp.32-37
    • /
    • 1997
  • 안전조치 측면에서 관심의 대상이 되어온 중수형 원전의 건식저장고 및 사용후 핵연료 이송 검증을 위한 안전조치 접근방법이 국가 계량관리 검사의 이행을 위하여 개발되었다. 이는 IAEA 사찰장비를 활용하지 못하는 우리나라의 현실을 반영하여 자체 개발된 비파괴검증장비가 이용되며, IAEA 안전조치 기준을 만족시킬 것으로 기대된다. 건식저장고에 대한 국가 계량관리 검사기준은 자체 개발된 비파괴검증장비와 봉인에 의존하는 기준이 제안되었으며, 검증활동은 시설운영자의 부담경감을 위하여 IAEA 사찰이 실시되는 기간동안 동시에 실시되도록 되어 있다. Transfer campaign 검증을 위하여 3명의 국가 계량관리 검사관이 검증활동에 참여하게 되며, 이를 통하여 이송작업의 연속성 유지 및 시설운영자의 부담경감 등이 달성됨과 함께 사참량의 감소가 기대된다. 본 논문은 국가 계량관리 검사의 시작과 함께 현실적인 어려움을 극복하면서, IAEA의 안전조치 기준을 만족하는 안전조치 접근방법을 제시하고 있으며, 안전조치 목적을 보다 적합하게 달성할 것으로 기대된다.

  • PDF

A Study on Vibration Effect of Sensitive Equipment for Aero-acoustics (공조 소음에 기인하는 정밀 장비 진동 영향에 관한 연구)

  • Ryu, Kuk-Hyun;Lee, Hong-Ki;Park, Hae-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.236-239
    • /
    • 2005
  • 본 연구에서는 정밀 측정/검사장비의 운영상 발생하는 에러의 원인을 규명하기 위함이다. C/R에 사용되어지는 정밀측정/검사장비는 장비 기초에 대하여 진동허용규제치를 장비 제작업체 제공한다. 이에 C/R 구조 및 장비 기초에 대하여 진동원 차단 방안등을 수행하게된다. 이러한 진동허용규제치를 만족시키기 위한 방안을 수행함에도 공조 소음등과 같은 요인에 의한 장비의 운영상 발생하는 진동과 관련된 에러를 규명하고 이를 제어하기 위한 연구를 수행하였다.

  • PDF

O-ring Size Measurement Based on a Small Machine Vision Inspection Equipment (소형 머신 비전 검사 장비에 기반한 O링 치수 측정)

  • Jung, YouSoo;Park, Kil-Houm
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.41-52
    • /
    • 2014
  • In this paper, O-ring size measurement algorithm based on a small machine vision inspection equipment which can replace a expensive and large machine vision inspection equipment is presented. The small machine vision inspection equipment acquires a image from a CCD camera shooting a measurement plane which located on a back light and the proposed size measurement algorithm is apply to the image. For improvement of size measurement accuracy, camera lens distortion correction and perspective distortion correction are conducted by software technique. Consider O-ring's shape, ellipse fitting model is applied. In order to increase the reliability of ellipse fitting, RANSAC algorithm is applied.

Color Compensation Method for Non-Contact Color Inspection on Plasma Display Panel (플라즈마 디스플레이 패널에서 비접촉식 칼라 검사를 위한 칼라 보정 방법)

  • 도현철;김우섭;진성일;태흥식
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.71-75
    • /
    • 2004
  • An efficient color compensation method is proposed to reduce the color difference between the camera based inspection system and the colorimeter based inspection system in a plasma display panel production line. The color compensation matrix can be constructed by using the relationship between RGB to XYZ conversion matrices, which are obtained by the RGB primaries and reference white chromaticity coordinates. Experimental results show that the non-contact color inspection system using the proposed color compensation method satisfactorily compensates the chromaticity coordinates acquired by the area color CCD camera to be matched to those measured by the colorimeter for various test color.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Development of a Framework for Anti-Collision System of Moving Drilling Machines on a Drill Floor (시추 작업장의 이동식 시추 장비 충돌 방지 시스템을 위한 프레임워크 개발)

  • Lee, Jaeyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.330-336
    • /
    • 2020
  • An anti-collision system between equipment is essential on a drill floor where multiple moving machines are operated simultaneously. This is to prevent accidents by halting the machines when required, by inspecting possibility of a collision based on the relative position data sent by the equipment. In this paper, we propose a framework for an Anti-Collision System (ACS) by considering expandability of the number of machines and computational speed, to promote development of drilling machines and corresponding ACS software. Each drilling equipment is represented as an object in the software with its own message format, and the message is constructed with serialization/deserialization to manage any additional equipment or data. The data handling process receives the current status of machines from the drilling control network, and relays a collision related message (including bypass signal) back to the machines. A commercial visualization software shows the bounding boxes moving with the equipment and indicates probable collision. It has been determined that the proposed system maintains total execution time below 5ms to process data from the network and relay the information hence, the system has no effect on the machine control systems having 100ms control cycle.

An On-the-fly Filtering Technique for Reducing Packet Inspection Overhead Against Worms and DDoS Attack (웜이나 DDoS 공격에 대한 패킷 검사 부하를 줄이는 간편 필터링 기법)

  • Ryu, Jin-Hyong;Lee, Jea-Kook;Kim, Sang-Min;Kim, Hyong-Shik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.57-61
    • /
    • 2008
  • 대부분의 보안 장비들은 웜이나 DDoS 공격들을 탐지하거나 차단하기 위하여 시그너쳐(signature) 검사방법을 이용한다. 웜이나 DDoS 공격은 네트워크에 부하를 주기 때문에 정상 서비스의 이용을 제한하고 심지어 보안장비를 동작하지 못하게 함으로써 네트워크를 마비시킬 수 있다. 본 논문에서는 패킷 유입량이 보안장비가 처리할 수 있는 범위를 벗어나면, 간편 필터를 이용하여 패킷 검사 오버헤드를 줄여 보안장비들의 가용성을 높이는 기법을 제안한다. 그리고 기존의 대표적인 웜들과 DDoS 공격 성향을 조사하여 타당성을 보인다.

  • PDF