• Title/Summary/Keyword: 검사체적

Search Result 159, Processing Time 0.028 seconds

Quantitative analysis of three dimensional volumetric images in Chest CT (흉부 CT 검사에서 3차원 체적 영상의 정량적 분석)

  • Jang, Hyun-Cheol;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.255-260
    • /
    • 2011
  • We wanted to evaluate the usefulness of three-dimensional reconstructive images using computed tomography for rib fracture patients. The reconstruction used in clinical multi planar reformation(MPR), volume rendering technique(VRT), and image data using quantitative methods and qualitative methods were compared. Much more, the artifact shadow was minimized to reconstruct with 3D volumetric image by using an law data in the analysis of the reconstructive image and chest CT scan of the evaluation result fractures of the thoracic patient. And we could know that the fractures of the thoracic determination and three dimension volume image reconstruction time were reduced.

Propagation of Bulk Longitudinal Waves in Thin Films Using Laser Ultrasonics (레이저 초음파를 이용한 체적종파의 박막 내 전파특성 연구)

  • Kim, Yun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.266-272
    • /
    • 2016
  • This paper presents the investigation of the propagation behavior of bulk longitudinal waves generated by an ultrafast laser system in thin films. A train of femtosecond laser pulses was focused onto the surface of a 150-nm thick metallic (chromium or aluminum) film on a silicon substrate to excite elastic waves, and the change in thermoreflectance at the spot was monitored to detect the arrival of echoes from the film/substrate interface. The experimental results show that the film material characteristics such as the wave velocity and Young's modulus can be evaluated through curve-fitting in numerical solutions. The material properties of nanoscale thin films are difficult to measure using conventional techniques. Therefore, this research provides an effective method for the nondestructive characterization of nanomaterials.

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

Feasibility Study on Diagnosis of Material Damage Using Bulk Wave Mixing Technique (체적파 혼합기법을 이용한 재료 손상 진단 적용 가능성 연구)

  • Choi, Jeongseok;Cho, Younho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • Ultrasonic nonlinear evaluation is generally utilized for detection of not only defects but also microdamage such as corrosion and plastic deformation. Nonlinearity is determined by the amplitude ratio of primary wave second harmonic wave, and the results of its comparison are used for evaluation. Owing to the experimental features, the experimental nonlinearity result contains system nonlinearity and material nonlinearity. System nonlinearity is that which is unwanted by the user; hence, it acts as an error and interrupts analysis. In this study, a bulk wave mixing technique is implemented in order to minimize the system nonlinearity and obtain the reliable analysis results. The biggest advantage of this technique is that experimental nonlinearity contains less system nonlinearity than that for the conventional nonlinear ultrasonic technique. Theoretical and experimental verifications are performed in this study. By comparing the results of the bulk wave mixing technique with those of the conventional technique, the strengths, weaknesses, and application validity of the bulk wave mixing technique are determined.

Fiber Volume Fraction Measurement of Fiber Reinforced Plastics by Using Gamma-Ray (감마선을 이용한 복합재료의 섬유체적분율 측정)

  • Jang, J.H.;Cho, K.S.;Chang, H.K.;Park, J.H.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.3
    • /
    • pp.151-155
    • /
    • 1997
  • In this research, nondestructive test using a radioisotope, $^{241}Am$ gamma-ray, was accomplished in order to evaluate the fiber volume fraction of the accumulated composite layers such as glass fiber/epoxy and carbon fiber/epoxy. Attenuation coefficients of the fiber and resin were measured respectively by NaI(T1) detector The fibers volume fraction was measured for various thickness of composite layers between 2 and 20mm. Fiber volume fraction of the composite layers were also measured for various amount of fibers. The experimental errors from nondestructive test using gamma-ray were in the range of ${\pm}1{\sim}2.5%$ in comparison with those from observation by optical microscopy. By selecting the optimum energy and activity of radioisotope, this method can provide a new means for the evaluation of the fiber volume fraction.

  • PDF

Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes (체적골밀도 측정법 동향: 수술부위 골밀도 분석)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.53-59
    • /
    • 2022
  • DEXA, as the standard areal bone mineral density (aBMD) measurement method, often shows an insuficient correlation between aBMDs of the measured bones and referring bones and is inaccurate due to the mass effect. In contrast, quantitative computer tomography (QCT), as a volumetric BMD (vBMD) measurement method, is being advanced so that it uses less radiation before, owing to improved CT device and computer imaging technology. Because dual-energy CTs can modulate the image signals showing tumor or specific chemicals as well as the ability to measure vBMD, they are expanding their application. For pre-checking vBMD of surgeon-specific bone volume at implantation candidate sites, a finite element creation-based local vBMD measurement technique was developed. The local vBMD measurement function for surgeon-specific shape volumes will be added to clinical imaging systems.

Numerical Modeling of Elastic Wave Scattering in an Isotropic Medium Containing an Orthotropic Inclusion (직교이방성 함유체를 포함하는 등방성 기지에서의 탄성파 산란 수치해석 모델)

  • Lee, Jung-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.69-79
    • /
    • 2001
  • A volume integral equation method(VIEM) is applied for the effective analysis of elastic wave scattering problems in unbounded solids containing general anisotropic inclusions. It should be noted that this newly developed numerical method does not require the Green's function for anisotropic inclusions to solve this class of problems since only the Green's function for the unbounded isotropic matrix is Involved In their formulation for the analysis. nis new method can also be applied to general two-dimensional elastodynamic problems with arbitrary shapes and number of anisotropic inclusions. Through the analysis of plane elastodynamic problems in unbounded isotropic matrix with an orthotropic inclusion, it is established that this new method is very accurate and effective for solving plane elastic problems in unbounded solids containing general anisotropic inclusions.

  • PDF

Qualification Requirements of Ultrasonic Examination Personnel for Preservice/Inservice Inspection of Nuclear Power Plant Components (원전(原電) 가동(稼勳) 중검사(中檢査) 초음파탐상검사(超音波探傷檢査) 요원(要員)에 대한 자격인정(資格認定) 요건(要件))

  • Lee, Jong-Po
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.1
    • /
    • pp.29-39
    • /
    • 1993
  • 초음파탐상검사는 그 검사결과가 여타 비파괴검사법에 비해 검사자, 검사장비, 절차서 등 검사 시스템에의 의존도가 높으며, 이중에서도 특히 검사자의 능력과 숙련도에 크게 좌우된다. 따라서 검사결과의 신뢰도를 높이기 위해서는 무엇보다도 검사자에 대해 엄격한 자격인정(Qualification)이 필요하다. 초음파탐상검사는 원자력 발전소 기기의 가동전중검사시 가장 많이 적용하는 체적검사법으로써, 결함검출 및 평가의 신뢰도를 확보하기 위하여 최근 관련 기술기준에서는 검사자에 대해 보다 엄격한 자격인정을 요구함과 아울러 초음파탐상검사 시스템(검사자, 장비, 절차서)에 대한 기량검증(Performance Demonstration)까지를 요구하고 있다. 위의 두 가지 요건을 성공적으로 충족시킬 수 있다면, 초음파탐상기술의 신뢰도는 크게 향상될 것이다. 본고에서는 최근 보다 강화된 원전 가동전중검사 초음파탐상검사 요원의 자격인정요건에 대해 자세히 알아봄으로써 관련 국내 기술기준의 제정과 앞으로 국내 원전 초음파탐상 검사요원에 대한 본 자격인정요건의 적용에 대비코자 하였다. 한편, "초음파탐상검사 시스템에 대한 기량검증 요건"은 초음파탐상 검사요원의 자격인정 요건과 밀접한 관계가 있으므로 다음에 별도로 기술코자 한다.

  • PDF

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.