A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen (복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Je-Bong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • 1. Purpose : This study is to present effective exposure conditions to acquire the best image of simple abdomen in Film Screen (F.S) system and Computed Radiography (C.R) system. 2. Method : In the F.S system, while an exposure condition was fixed as 70kVp, images of a patients simple abdomen were taken under the different mAs exposure conditions. Among these images, the best one was chosen by radiologists and radiological technologists. In the C.R system, the best image of the same patient was acquired with the same method from the F.S system. Both characteristic curves from F.S system and C.R system were analyzed. 3. Results : In the F.S system, the best exposure condition of simple abdomen was 70kVp and 20mAs. In the CR system, with the fixed condition at 70kVp, the image densities of human organs, such as liver, kidney, spleen, psoas muscle, lumbar spine body and iliac crest, were almost same despite different environments (3.2mAs, 8mAs, 12mAs, 16mAs and 20mAs). However, when the exposure conditions were over or under (below) 12mAs, the images between the abdominal wall and the directly exposed part became blurred because the gap of density was decreased. In the C.R system, while the volume of mAs was decreased, an artifact of quantum mottle was increased. 4. Conclusion : This study shows that the exposure condition in the C.R system can be reduced 40% than in the F.S system. This paper concluded that when the exposure conditions are set in CR environment, after the analysis of equipment character, such as image processing system(EDR : Exposure Data Recognition processing), PACS and so on, the high quality of image with maximum information can be acquired with a minimum exposure dose.

  • PDF

A Study on the DWI and Pathologic Findings of Cancer Cells (암 세포주의 확산강조영상과 병리학적 관계에 관한 연구)

  • Seong, Jae-Gu;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.239-244
    • /
    • 2011
  • In this study, we evaluated diffusion weighted imaging (DWI) to investigate whether the DWI parameters can predict characteristic parameters on pathologic specimens of tumor or not. CFPAC-1 was injected subcutaneously on the back flank of athymic nude mice (n=13) then two tumors were initiated on each mouse (2${\times}$13=26 tumors). The mice were sacrificed to make specimen immediately after initial MR imaging then were compared with the MR image. A dedicated high-field (7T) small-animal MR scanner was used for image acquisitions. A T1 and T2 weighted axial image using RARE technique was acquired to measure the T2 values and tumor size. DWI MR was performed for calculating ADC values. To evaluate tumor cellularity and determine the levels of MVD, tumor cells were excised and processed for H-E staining and immunostaining using CD31. T2 values and ADC values were computed and analyzed for each half of the tumors and compared to the correlated specimens slide. Median ADC within each half of mass was compared to the cellularity and MVD in the correlated area of pathologic slide. The mean of ADC value is $0.7327{\times}10^{-3}$ $mm^2/s$ and standard deviation is $0.1075{\times}10^{-3}$ $mm^2/s$. There is a linear relationship between ADC value and tumor necrosis (R2=0.697, p< 0.001). DW image parameters including the ADC values can be utilized as surrogate markers to assess intratumoral neoangiogenesis and change of the internal structure of tumor cells.

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Regeneration of a defective Railroad Surface for defect detection with Deep Convolution Neural Networks (Deep Convolution Neural Networks 이용하여 결함 검출을 위한 결함이 있는 철도선로표면 디지털영상 재 생성)

  • Kim, Hyeonho;Han, Seokmin
    • Journal of Internet Computing and Services
    • /
    • v.21 no.6
    • /
    • pp.23-31
    • /
    • 2020
  • This study was carried out to generate various images of railroad surfaces with random defects as training data to be better at the detection of defects. Defects on the surface of railroads are caused by various factors such as friction between track binding devices and adjacent tracks and can cause accidents such as broken rails, so railroad maintenance for defects is necessary. Therefore, various researches on defect detection and inspection using image processing or machine learning on railway surface images have been conducted to automate railroad inspection and to reduce railroad maintenance costs. In general, the performance of the image processing analysis method and machine learning technology is affected by the quantity and quality of data. For this reason, some researches require specific devices or vehicles to acquire images of the track surface at regular intervals to obtain a database of various railway surface images. On the contrary, in this study, in order to reduce and improve the operating cost of image acquisition, we constructed the 'Defective Railroad Surface Regeneration Model' by applying the methods presented in the related studies of the Generative Adversarial Network (GAN). Thus, we aimed to detect defects on railroad surface even without a dedicated database. This constructed model is designed to learn to generate the railroad surface combining the different railroad surface textures and the original surface, considering the ground truth of the railroad defects. The generated images of the railroad surface were used as training data in defect detection network, which is based on Fully Convolutional Network (FCN). To validate its performance, we clustered and divided the railroad data into three subsets, one subset as original railroad texture images and the remaining two subsets as another railroad surface texture images. In the first experiment, we used only original texture images for training sets in the defect detection model. And in the second experiment, we trained the generated images that were generated by combining the original images with a few railroad textures of the other images. Each defect detection model was evaluated in terms of 'intersection of union(IoU)' and F1-score measures with ground truths. As a result, the scores increased by about 10~15% when the generated images were used, compared to the case that only the original images were used. This proves that it is possible to detect defects by using the existing data and a few different texture images, even for the railroad surface images in which dedicated training database is not constructed.

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

Efficacy of Self-manipulation Technique in the Treatment of Patients with Anterior Disc Displacement without Reduction (비정복성 관절원판 전방변위 환자의 치료에 있어서 자가 수조작술의 효과에 대한 연구)

  • Kim, Ju-Sik;Lee, Chae-Hoon;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • Internal derangement of the temporomandibular joint(TMJ) is defined as an abnormal relationship of the articular disc to the condyle. Mandibular manipulation is one of the conservative treatments to be considered first to manage the patients with anterior disc displacement without reduction. Mandibular manipulation is used to increase articular mobility and to restore the displaced disc into an anatomically normal position. While Farrar's technique has been popularly used, Minagi et al., Mongini and Suarez introduced the manipulation technique conducted by the patients themselves. But there is no study on the efficacy of self-manipulation technique, comparing with conventional one. The aim of this study was to investigate the efficacy of the conventional and self-manipulation technique, which was modified to complement the previously described technique by Minagi et al., in the treatment of patients with anterior disc displacement without reduction. TMD patients, who visited Department of Oral Medicine of Seoul National University Dental Hospital from December, 2002 to November, 2004 and were diagnosed as anterior disc displacement without reduction by TMJ magnetic resonance imaging (MRI) were enrolled. Conservative treatments including physical therapy, exercise, behavioral therapy, stabilization splint therapy, and manipulation therapy were done to every single patient until the symptomsimproved enough to discharge the patient. The charts were reviewed retrospectively according to the type of manipulation. In the results, patients whose maximum mouth opening was more than 40 mm was higher in the self-manipulation group(69.9%) than in the conventional manipulation group(42.9%). But difference between two groups was not significant. According to the fact that we decided to discharge the patients whentheir mouth opening increased to more than 40 mm and subjective symptoms such as pain and discomfort were improved as well, treatment period of discharged patients was significantly shorter in the self-manipulation group($29.2{\pm}12.3$ weeks) than in the conventional manipulation group ($61.0{\pm}38.0$ weeks) (p<0.01). In conclusion, in the treatment of TMD patients with anterior disc displacement without reduction, the self-manipulation technique which is performed by patients themselves is an effective treatment modality for increasing the range of mouth opening and shortening the total treatment period.

Endoscopic Retrieval of Esophageal Fishhooks Using Cerclage Wire: A Case Report (내시경과 Cerclage Wire를 이용한 식도내 낚시바늘 제거: 증례보고)

  • Kim, Young-Ki;Uhm, Mi-Young;Seo, Eu-Gene;Ha, Mi-Hyun;Wang, Ji-Hwan;Jeong, In-Jo;Chang, Hong-Hee;Lee, Hee-Chun;Cho, Kyu-Woan;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.622-626
    • /
    • 2007
  • A 1.6-year-old, intact male beagle dog was presented with three day history of odynophagia and anorexia. According to the history and radiographic findings, the patient was diagnosed with esophageal and gastric foreign body due to ingesting fishhooks. Gastroesophagoscopy revealed that one fishhook located in the thoracic esophagus cranial to the heart base and the other located in the cardia region were connected with a single fishing line. Gastrotomy was performed to remove the fishhook in the cardia region and to sever the connecting fishing line. After gastrotomy, endoscopic attempts to remove the esophageal fishhook with a three, five pronged endoscopic grasping forceps, and a biopsy were unsuccessful because the fishhook was embedded deeply in the mucosa membrane. A handmade cerclage wire(16G) shaped like a snare forceps was advanced into the esophagus while visualizing the fishhook endoscopically. The cerclage wire was used to hang and retract the foreign body. The fishhook was retracted orally, resulting in successful removal. Ten days after the operation, the patient fully recovered and was discharged.

Quality Analysis of Fly Ash Through Correlation between Density by Hydrometer and Test Report (Hydrometer법을 이용한 밀도 측정값과 시험 성적서간 상관분석을 통한 플라이애시의 품질특성 분석)

  • Song, Heung-Ho;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.305-312
    • /
    • 2017
  • To evaluate the reliability of fly ash quality supplied to ready-mixed concrete plant using mass cylinder and hydrometer, in this research, the correlationship between the fly ash properties provided from certification and density measurement with suspension was evaluated. As a result, the reliability of the certification, except fineness and loss on ignition, all properties had a discord. Additionally, in the case of density, fineness, and L.O.I, the relation with the density measured using hydrometer showed high correlation, especially fineness was strongly related with the density measured using hydrometer. Furthermore, according to the comparative analysis with previous research, the fly ash used in this research was similar measurement with raw powder without any refining process, it is considered that the constant error of blaine test or using raw ash sample as a fly ash. In current standard regarding fly ash, the fineness range of class 2 can be changed from $3,000-4,500cm^2/g$ to $3,500-4,500cm^2/g$ for improved quality of fly ash in fineness aspect.

Functional MRI of Language Area (언어영역의 기능적 자기공명영상)

  • 유재욱;나동규;변홍식;노덕우;조재민;문찬홍;나덕렬;장기현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • Purpose : To evaluate the usefulness of functional MR imaging (fMRI) for language mapping and determination of language lateralization. Materials and Methods : Functional maps of the language area were obtained during word generation tasks and decision task in ten volunteers (7 right handed, 3 left-handed). MR examinations were performed at 1.5T scanner with EPI BOLD technique. Each task consisted of three resting periods and two activation periods with each period of 30 seconds. Total acquisition time was 162 sec. SPM program was used for the postprocessing of images. Statistical comparisons were performed by using t-statistics on a pixel-by- pixel basis after global normalization by ANCOVA. Activation areas were topographically analyzed (p>0.001) and activated pixels in each hemisphere were compared quantitatively by lateralization index. Results : Significant activation signals were demonstrated in 9 of 10 volunteers. Activation signals were found in the premotor and motor cortices, the inferior frontal, inferior parietal, and mid-temporal lobes during stimulation tasks. In the right handed seven volunteers, activation of language areas was lateralized to the left side. Verb generation task produced stronger activation in the language areas and higher value of lateralization index than noun generation task or decision task. Conclusion : fMRI could be a useful non-invasive method for language mapping and determination of language dominance.