A Visual Detecting System for The Rotation Axis of Golf Ball (영상 기반 회전 골프공 무게중심 검출 시스템)

  • Hyun, Woong-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.411-416
    • /
    • 2019
  • In this paper, we describe a measurement system based on vision for detecting the rotation axis of dimpled golf ball. Some golf balls have wrong rotation axis owing to bad production and scratch. A flying golf ball makes sliced or curved motion mainly to owing the wrong rotation axis of golf ball. Dimples of golf ball make a golf ball higher and more straight flying. When we hit a golf ball by driver or iron club, the dimpled ball flies straight and rotates as well. While the ball flying, the rotating axis of the ball convergence. And this makes the ball motion curved. If we hit a golf ball in direction of the rotation axis, the flying ball makes straight motion. In this paper, we develop a control system to detect convergence axis and time of flying golf ball based on vision system. To show validity of the developed system, We experimented several case for dimpled golf balls.

Spatial Dose Distribution for C-arm Examination within Operation Room Using Monte Carlo Method (몬테카를로 방법을 이용한 이동형 X선 투시검사 시 수술실 내 공간선량평가)

  • Kim, Jung-Hoon;Shin, Eom-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.205-210
    • /
    • 2021
  • The purpose of this study was to analyze the spatial dose according to the distance by location of medical workers when using a mobile X-ray fluoroscopy device in the operating room through a simulation experiment. The MCNPX program was used for the simulation, and the location of medical workers was set around the operating table, and the spatial dose distribution according to the distance and changes in imaging conditions was evaluated. As a result, The highest score was 2.74×10-4 mGy, 2.72×10-4 mGy, and 1.18×10-4 mGy based on the 10 cm distance from the operating table. Spatial dose depending on the distance 100cm, A point 5.15×10-5 mGy is decreased 19% of 10cm, D point 5.12×10-5 mGy, 19 % of 10cm, and G pint, 1.73×10-5 mGy is reduced by 15% of 10cm. Based on this study, medical-related workers directly or indirectly participating in surgery carry potential risks of radiation exposure during surgery, but there are difficulties in radiation protection due to the nature of their work. Therefore, efforts to reduce exposure suitable for the operating room environment will be required.

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.

Development of a Smartphone-based Total Bilirubin Measuring System for Screening of Jaundice (황달 선별검사를 위한 스마트폰 기반의 총빌리루빈 측정시스템의 개발)

  • Kim, Won-Jung;Song, Eunji;Rhee, Joowon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2021
  • Hyperbilirubinemia is the most common neonatal disease and is observed in about 80% of newborns worldwide in neonatal period within a week after birth. Untreated infant hyperbilirubinemia may lead to brain damage and even death, so it is very important to diagnose it quickly and accurately. In this study, a total bilirubin measurement system was developed that is portable and easy to use without pre-processing using a commercial smartphone. This system measures using the LED and camera of the smartphone without the need for additional devices, and because a small amount of blood is injected without pre-treatment, anyone can easily measure it in the field. In a comparative study with Cobas c111 results, accuracy meets CLIA guidelines with 94% (17/18) within ±0.4 mg/dL below 3 mg/dL and 98% within ±20% above 3 mg/dL (276/282). This system offers a simple, fast and accurate diagnosis for jaundice in infants and young children in low-resource settings.

A Study of the Development Safety Criteria for Hybrid Electrical Propulsion Fishing Boats (전기복합 추진어선의 안전기준 개발에 관한 연구)

  • Cheol eon Kang;Chul ho Baek;Sung hun Kim;Chan jae Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.207-214
    • /
    • 2023
  • Ships emit significant amounts of air pollution. To reduce ship emissions, the government has implemented the Eco-Friendly Ship Act to improve the marine air environment, under which the use of eco-friendly ships that use eco-friendly energy as a power source encouraged and technologies to reduce marine pollution are developed. Therefore, the revision of relevant laws and systems such as inspection and facility standards for the safe operation of eco-friendly ships is urgently needed, especially those for fishing vessels, which account for the majority of domestic coastal vessels. This study defines the core equipment for the application of electric complex propulsion systems to fishing boats and presents a minimum safety standard plan for the adoption and dissemination of eco-friendly fishing boats.

Analysis of Learning Effects MRI Education Content based on Virtual Reality (가상현실 기반 MRI 교육 콘텐츠 학습효과 분석)

  • Jung-Hun Lee;Jae-Goo Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2023
  • In order to overcome practical limitations in installing, managing and operating MRI machines with expensive equipment, this study developed and utilized virtual reality (VR) experience education by combining virtual reality (VR) with magnetic resonance imaging devices. The Students who experienced virtual reality-based educational systems were surveyed to identify possible side effects during the experience and self-directed learning ability and academic self-efficacy surveys were conducted to analyze the impact of virtual reality-based practice on learning. In the analysis of the self-directed learning ability survey there was no difference in the average between the student group who experienced education and the student group who did not but there was a significant difference in the average for each group. Virtual Reality-based practical education is expected to provide an efficient practice system by providing new learning methods and opportunities for education that can be repeated anytime, anywhere regardless of time and space.

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

A Study on Rapid Color Difference Discrimination for Fabrics using Digital Imaging Device (디지털 화상 장치를 이용한 섬유제품류 간이 색차판별에 관한 연구)

  • Park, Jae Woo;Byun, Kisik;Cho, Sung-Yong;Kim, Byung-Soon;Oh, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.29-37
    • /
    • 2019
  • Textile quality management targets the physical properties of fabrics and the subjective discriminations of color and fitting. Color is the most representative quality factor that consumers can use to evaluate quality levels without any instruments. For this reason, quantification using a color discrimination device has been used for statistical quality management in the textile industry. However, small and medium-sized domestic textile manufacturers use only visual inspection for color discrimination. As a result, color discrimination is different based on the inspectors' individual tendencies and work procedures. In this research, we want to develop a textile industry-friendly quality management method, evaluating the possibility of rapid color discrimination using a digital imaging device, which is one of the office-automation instruments. The results show that an imaging process-based color discrimination method is highly correlated with conventional color discrimination instruments ($R^2=0.969$), and is also applicable to field discrimination of the manufacturing process, or for different lots. Moreover, it is possible to recognize quality management factors by analyzing color components, ${\Delta}L$, ${\Delta}a$, ${\Delta}b$. We hope that our rapid discrimination method will be a substitute technique for conventional color discrimination instruments via elaboration and optimization.