• Title/Summary/Keyword: 검사장치

Search Result 1,054, Processing Time 0.035 seconds

A Study on the Heating of Lipiodol during Lymphangiography (림프관 조영술 시 리피오돌의 가온에 관한 고찰)

  • Kang, Rae-Wook;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.597-602
    • /
    • 2020
  • The study was conducted to improve the efficiency of the test and to reduce the exposure dose of patients and operators by analyzing the difference in the moving speed of Lipiodol according to the temperature during lymphography. The device for injecting Lipiodol at a constant pressure was self-made, and after inserting Lipiodol into the Connecting Tube, the moving speed of the contrast agent was photographed at temperatures of 26℃, 36℃, and 46℃ using a heat transfer device. Lipiodol movement time from the Support Catheter to 20cm was measured and analyzed, and statistical significance was confirmed. In the 46℃ environment, the average moving time was 11 seconds, at 36℃ the average was 13 seconds, and at 26℃ the average was 17 seconds. Lipiodol showed a significant difference in moving time with increasing temperature (p<.001), and it was confirmed that the higher the temperature, the faster the moving speed. In the case of lymphangiography, when heated to a certain temperature (46 degrees) rather than injecting Lipiodol at room temperature, the injection speed can be increased and the speed of movement in the lymphatic vessel can be improved.

Scanning Acoustic Microsope System Using 200MHZ ZnO Transducer (ZnO를 이용한 초음파 현미경의 제작과 평가)

  • Jang, Ji-Won;Do, Si-Hong;Lee, Jong-Gyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.4
    • /
    • pp.200-208
    • /
    • 1989
  • To the purpose of preparation for investigating aspect of material that not revealed by the light microscope and extending our knowledge in applicable field, a scanning acoustic microscope system of 200MHz was organized and appraised its performance with experiments. Professor N.CHUBACHI in Tohoku University in Sendai, Japan provided the ZnO transducer with lens. The system for transmitting and receiving ultrasonic pulses of 200nsec was organized with a rectangular audio wave generator for modulation of 200MHz carrier wave, gating system for transmitting and receiving, mixer for converting intermediate frequency, a directional coupler, ZnO transducer, radio frequency amplifiers. detecter and personal computer. The Scanning system was driven in micro steps with three stepping motors in the direction of x, y and z axes. The system was a reflecting type scanning acoustic microscope and the operation program processed graphics data from receiving echo intensities. Photograph of fish scale obtained by optical microscope was compared with its image by the scanning acoustic microscope organized here. The result was satisfiable.

  • PDF

The development of small water-jet propulsion for 150HP grade inboard type (150마력급 선내형 소형 워터제트 추진시스템 개발)

  • Lee, Joong-Seop;Lee, Chi-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.246-252
    • /
    • 2014
  • This study is on the development of 150PS inboard type of compact water jet propulsion system. The water jet is composed of intake, impeller, diffuser, reverse bucket and main shaft. Components of water jet have been manufactured through precision processing after sand casting. Development of water jet propelled engine has been finally completed by processes which are design, production and inspection on each component. The water jet performance characteristics show that 0.29 m3/s of maximum flow rate and 37 m/s of flow velocity have been secured in the ground test pool. Field test was performed by 21ft test ship that water jet propulsion equipment developed in this study was installed. As a result, the weight of hull, engine and other parts of the ship has been almost 1.2 ton and 45 km/h of maximum sailing speed has been recorded with 3700 rpm of engine in the domestic coast test.

Reliability of Infrared Thermographic Imaging in the Orofacial Region (구강안면부에서 적외선 체열검사의 신뢰도에 관한 연구)

  • Han, Dong-Joon;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.355-367
    • /
    • 2001
  • 치의학 분야에서 디지탈 근적외선 체열측정 장치(digital infrared thermographic imaging; DITI)의 응용이 미미한 것은 과거 열측정장치의 기술력이 부족한 것이 주된 요인이었다. 그러나 최근들어 기술이 진보함에 따라 실시간 열영상을 재현할 수 있게 되었고 이는 치의학 및 의학계에 많은 관심을 일으키고 있다. 지금까지의 연구를 보면 두개하악장애시 구강영역의 온도변화의 임상적 효용 가능성을 제시하였으나 안면 및 두경부에 대한 실제 기기 및 측정방법의 신뢰도에 대한 연구는 이루어지지 못한 상태이다. 본 연구에서는 DITI에 대한 신뢰도를 조사하였다. DITI의 모니터 상에서 비활동성 발통점의 부위를 찾아내기가 쉽지 않다. 따라서 모니터상에서 안면발통점(joint, temporalis anterior, masseter anterior, masseter inferior)의 부위를 찾아 온도를 찾아내는 방법과 미리 발통점 피부상에 링모양의 마크를 부착하여 모니터상에서 쉽게 찾아내는 방법을 사용하여 신뢰도를 조사하여 비교한 결과 다음과 같다. 1. 조사한 발통점 중에서 temporalis anterior, joint, masseter anterior과 masseter inferior의 순서로 피부온도가 유의하게 온도가 높았으나(p<0.05) masseter 내에서는 유의한 차이를 보여주지 않았다. 2. 4개의 발통점 모두에서 높은 열적 대칭성을 보였으며, 좌우 온도차이는 $0.1^{\circ}C$미만이었다. 3. 다른 시기에 조사한 조사자내 신뢰도는 두 조사자 모두 높은 상관관계를 보여주지 않았으며 대조군과 마크를 사용한 군간에는 뚜렷한 차이를 볼 수 없었다. 4. 동일한 시기에 조사한 조사자간 신뢰도는 두 시기 모두 joint 부위의 일부를 제외하고 높은 상관관계를 보여주었으며, 마크를 사용한 경우 사용하지 않은 경우 보다 훨씬 신뢰도가 높은 상관관계를 나타내었다. 이상의 결과로 보아 DITI는 두개하악장애환자에 대한 두경부 발통점의 온도변화를 측정하는 데 있어 시간에 따른 신뢰도는 결여되었으나 동일 시기의 측정에는 매우 유익할 것으로 사료되며, 특히 발통점에 대한 표시를 사용하는 경우 매우 정확한 온도를 조사할 수 있을 것으로 판단된다.

  • PDF

V-Zn계 산화물을 이용한 마이크로볼로미터적외선 센서의 구현

  • Han, Myeong-Su;Kim, Dae-Hyeon;Choe, In-Gyu;Go, Hang-Ju;Eom, Ju-Beom;Park, Jae-Seok;Sin, In-Hui;Lee, Byeong-Il;Kim, Du-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.376.2-376.2
    • /
    • 2014
  • 마이크로볼로미터 적외선 센서는 인체감지, 전자부품의 품질검사, 에너지 절감, 산업시설감시 및 군사용으로 다양하게 적용되고 있다. 기존에 이러한 적외선 센서의 감지재료로 VOx 또는 비정질 Si이 가장 많이 사용되고 있으며, VOx는 감도가 높고, 세계적으로 가장 많이 사용되고 있는 물질이다. 본 연구에서는 기존의 VOx 박막 증착법을 개선하여 Zn 산화물 박막을 혼용한 적외선 감지재료를 이용한 마이크로볼로미터 제작 및 특성에 대해 보고한다. RF sputtering 방법으로 약 140 nm의 VOx/ZnO/VOx 샌드위치 박막을 증착하고, 산소분위기에서 열처리함으로써 온도저항계수(TCR)가 약 -3.0 %/K의 값을 갖는 특성을 구현하였다. 갓 증착된 V-Zn 박막에서는 XRD 스펙트럼에서는 V2O5 관련 피크가 주로 관측되었으며, 산소열처리에 의해 VO2 피크가 새롭게 관측되었다. 볼로미터 감지소자는 유효면적 $50{\times}50{\mu}m^2$ 으로 bulk micromaching 공정을 통해 제작하였다. Si 기판위에 SiNx 박막을 PECVD 장치를 이용하여 증착하였으며, 적외선 감지층으로 V-Zn 산화물을 RF sputtering 방법으로 증착하여 열처리 후 SiNx passivation 박막으로 보호하였다. 열적고립을 위해 패터닝 후 Si 기판을 KOH 용액을 이용하여 약 $20{\mu}m$ 식각하여 소자를 구현하였다. 제작된 소자의 특성을 평가한 결과 반응도는 1.57e+4 V/W, 탐지도는 $8.79e+7cmHz^{1/2}/W$를 얻을 수 있었다. 소자의 동작 특성을 평가하기 위해 진공 압력을 1e-3 torr 이하에서 thermoelectric cooler를 장착한 metal package를 제작하여 동작온도에 따른 특성을 평가하였다. 동작온도를 $10^{\circ}C{\sim}40^{\circ}C$로 하여 측정한 결과 동작온도가 증가할수록 신호전압은 감소함을 알 수 있었다.

  • PDF

OSEK OS Based Gateway for Interconnecting WAVE and CAN (WAVE와 CAN 연동을 위한 OSEK OS기반 게이트웨이)

  • Kim, Ju-Young;Seo, Hyun-Soo;Lee, Sang-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.133-141
    • /
    • 2014
  • Recently, various services are provided by using WAVE protocol for communication among neighboring vehicles. And in order to operate stable system, the gateway for interconnecting in and out vehicle networks is required. In this paper, we propose gateway interconnecting WAVE and CAN protocol. The proposed gateway based on OSEK OS consists of a communication layer, a message translator layer and a message management layer. In the communication layer, WAVE communication part and CAN communication part are designed to communicate with WAVE and CAN. And in the message management layer, message management layer functions to store the received messages and check errors with the message. Based on these functions, experiment was conducted to analyze performance of the gateway with two scenarios such as transmitting periodically BSM as a message structure for safety services in vehicle-to-vehicle communications and responding to road side equipments requiring in-vehicle information. As a result of test, we verify our gateway performance by analyzing measured time in test scenarios.

Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom (ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.629-635
    • /
    • 2016
  • ACR phantom for quality control of magnetic resonance imaging equipment can evaluate magnetic resonance imaging picture quality through various structures within the phantom. In this study, percent Signal Ghosting and Slice position accuracy of imaging could be analyzed by attaching implant and the wire for correction of tooth using ACR phantom in Head coil of 3.0T equipment. In the T1 weighted imaging of the first slice and the eleventh slice of implant, the slice position accuracy appeared to be good in ingress bandwidth 300, and it was good in ingress bandwidth 130 when wire for correction was attached. Percent Signal Ghosting in the seventh slice of SE T1 weighted imaging, implant and wire for correction added all appeared to be good when ingress bandwidth was 230. It is thought that in case of implant dental prosthesis patients in brain exam using magnetic resonance imaging, optimum image can be obtained by changing ingress bandwidth.

Volatile flavor components of soybean pastes manufactured with traditional Meju and improved Meju (재래식 메주와 개량식 메주로 제조한 된장의 휘발성 향기성분)

  • Ji, Won-Dae;Lee, Eun-Ju;Kim, Jong-Kyu
    • Applied Biological Chemistry
    • /
    • v.35 no.4
    • /
    • pp.248-253
    • /
    • 1992
  • Volatile flavor components of soybean pastes, manufactured with traditional Meju and improved Meju, were extrated by simultaneous steam distillation-extraction apparatus and concentrated at atmosphere press. The concentrates were investigated GC-sniff evaluation by preparative gas chromatograph, and then analyzed and identified by GC/MS and Kovats retention index. Thirty nine components, including 11 alcohols, 4 aldehydes, 2 pyrazines, 4 acids, 3 fuans, 3 phenols, 3 esters, 3 hydrocarbons, 1 ketone, 5 miscellous ones were confirmed in soybean paste manufactured with traditional Meju. Twenty one components, including 4 alcohols, 2 aldehydes, 2 pyrazines, 2 acids, 1 fuan, 2 esters, 1 hydrocarbon, 2 ketones, 4 miscellous ones were confirmed in soybean paste manufactured with improved Meju. Ten components such as 3-methyl-1-butanol, 4-methyl-3-heptanol, trimethyl-pyrazine, 1-octen-3-ol, 2-furancarboxaldehyde, tetramethyl-pyrazine, benzaldehyde, 3-methyl-butanoic acid, naphthalene, 2-ethyl-3-methyl-oxetane were identified together in soybean pastes manufactured with traditional Meju and improved Meju.

  • PDF

Bio-Signal Acquisition System Using Mobile Device (휴대용 개인 정보 단말기를 이용한 생체신호 획득 시스템)

  • Kim Hyung-Bae;Kwon Man-Jun;Cha Eun-Jong;Chun Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.349-354
    • /
    • 2005
  • In this paper, we propose a mobile telemedicine system that acquires more easily and analyzes individual's bio-signal using PDA. It is not easy for modern people who live busily, disabled patients, or old people to visit hospital. The major goal of this study is to implement the mobile telemedicine systems that the captured bio-signal from remote hospital or other medical treatment device is transmitted via Bluetooth module in ubiquitous environment, PDA with built-in Bluetooth module receives its data and displays on the screen in various form. By implemented systems, it is possible to compare current bio-signal with historical bio-signal and analyze bio-signal, and it is able to make a self diagnosis and it is available to be examined and treated remote diagnosis by sending stored bio-signal to a medical doctor.

New Measurement of Whitening Effects by Using Confocal Scanning Laser Microscope (CSLM) (Confocal Scanning Laser Microscope (CSLM)을 이용한 신규 미백 효과 측정 연구)

  • Kim, Myong Ki;Cho, Seok-Cheol;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.3
    • /
    • pp.279-285
    • /
    • 2015
  • Hyperpigmentation on face is a highly anxiety-producing symptom, especially for women from the aspect of beauty. Pigmentation of the skin is related to the amount of melanin that provides protection against UV radiation. In vivo reflectance confocal microscopy is a non-invasive imaging tool allowing visualization of the skin without tissue alteration, by placing a microscopy directly on the living skin. The aim of this study was to develop the new evaluation method of whitening effects using in vivo reflectance confocal microscopy and to validate other instruments for measuring skin colors, and UV-induced hyperpigmentation was elicited on the inside skin of the forearm. It suggested that the new method for whitening effects using the confocal microscopy was useful to evaluate the de-pigmentation products and to easy for understanding to customers.