• Title/Summary/Keyword: 검사장치

Search Result 1,054, Processing Time 0.025 seconds

A Study on Usefulness of Diffusion Tensor Imaging (DTI6D) in Brain Ischemic Disease (뇌 허혈성 질환 확산텐서영상(DTI6D)의 임상적 유용성에 관한 연구)

  • Goo, Eunhoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.223-228
    • /
    • 2013
  • We evaluated the usefulness of $DTI_{6D}$ which was acquiring six direction diffusion data through compared to $DWI_{3D}$. Mean SNR and CNR were on $DWI_{3D}$ and $DTI_{6D}$ $44.01{\pm}13.36$, $37.15{\pm}11.44$ (p=0.029) and $18.47{\pm}9.66$, $19.88{\pm}9.20$(p=0.017). The number of lesions were $311{\pm}26.87$, $224.5{\pm}26.16$(p=0.041) on $DTI_{6D}$ and $DWI_{3D}$. Twenty patients were the more detected brain infarction lesion on $DTI_{6D}$. But there is no one the more detected on $DWI_{3D}$. And the more three direction diffusion data could get more information. However, we need to consider about the time consumption compared to DWI.

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Full-mouth rehabilitation with increasing vertical dimension on the patient with severely worn-out dentition and orthognathic surgery history: A case report (악교정수술 병력을 가진 과도한 치아 마모를 보이는 환자의 수직고경 증가를 동반한 전악 수복 증례)

  • Sang-Myeong Tak;Chang-Mo Jeong;Jung-Bo Huh;So-Hyoun Lee;Mi-Jung Yun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.33-43
    • /
    • 2023
  • Pathological wear across the entire dentition causes problems such as collapsed occlusal plane, reduced vertical dimension, anterior premature contact, inadequate anterior guidance, and tooth migration, thereby induce symptoms such as temporomandibular joint disorder, reduced masticatory efficiency, and tooth hypersensitivity. For the treatment of patients with excessive wear, evaluation of vertical dimension should be preceded along with analysis of the cause. The patient in this case was a 45-year-old female with a history of orthognathic surgery. Through clinical examination, radiographic examination, and model analysis, overall tooth wear, interdental spacing in the anterior maxillary region, retruded condylar position, and insufficient interocclusal space for prosthetic restoration were confirmed. Full mouth rehabilitation with increased vertical dimension was planned, the patient's adaptation to the new vertical dimension was evaluated with a removable occlusal splint and temporary prosthesis, and cross-mounting was performed based on the temporary restoration to fabricate the definitive zirconia prosthesis, maintaining the adjusted vertical dimension. It showed satisfactory functional and esthetic results through stable restoration of the occlusal relationship.

Catadioptric NA 0.6 Objective Design in 193 nm with 266 nm Autofocus (이중 파장 심자외선 카타디옵트릭 NA 0.6 대물렌즈 광학 설계)

  • Do Hee Kim;Seok Young Ju;Jun Ho Lee;Hagyong Kihm;Ho-Soon Yang
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.2
    • /
    • pp.53-60
    • /
    • 2023
  • We designed a catadioptric objective lens with a 0.6 numerical aperture (NA) for semiconductor inspection at 193 nm. The objective lens meets major requirements such as a spatial resolution of 200 nm and a field of view (FOV) of 0.15 mm or more. We selected a wavelength of 266 nm for autofocus based on the availability of the light source. First, we built the objective lenses of three lens groups: a focusing lens group, a field-lens group, and an NA conversion group. In particular, the NA conversion group is a group of catadioptric lenses that convert the numerical aperture of the beam focused by the prior groups to the required value, i.e., 0.6. The last design comprises 11 optical elements with root-mean-squared (RMS) wavefront aberrations less than λ/80 over the entire field of view. We also achieved the athermalization of the objective lens with focus-shift alone satisfying the performance of RMS wavefront aberration below λ/30 at a temperature range of 20 ± 1.2 ℃.

MITIGATION OF MAXILLARY ANTERIOR TEETH PROTRUSION WITH CEREBRAL PALSY USING REMOVABLE APPLIANCE : A CASE REPORT (뇌성마비환자에서 가철성장치를 이용한 상악 전치부 돌출 완화 : 증례보고)

  • Min, Boram;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.9 no.2
    • /
    • pp.122-126
    • /
    • 2013
  • Cerebral palsy is one of the primary handicapping conditions of childhood. The prevalence of malocclusions in patients with cerebral palsy is approximately twice than in general population. Even though these high rates of malocclusions, most clinicians may feel uncomfortable about treating such problems to reduce inclination of anterior teeth because to reduce of protrusion makes to decrease risk of trauma. This is the case report about mitigation of maxillary anterior teeth protrusion in patient with cerebral palsy. A 14 year old boy who had cerebral palsy visited our dental hospital. He had severe protrusive maxillary anterior teeth and narrow arch form. He was experienced at using Castillo morales appliance in early childhood. He had mild mental retardation and was able to learn simple skills. He and his parents had willing to improve his dental problems. A gentle impression taking on maxilla was done. Removable appliance was made including median screw and labial bow. We provide a period of adaption for 3 weeks. After of anterior teeth through activation of labial bow was done once a month by dentist. The treatment carried out for 10 months and we could observe reduced labial inclination of maxillary right central incisor and more wide arch form. Hawley type retainer was set at maxilla for retention. In conclusion, accompanying careful case selection and treatment, patient with cerebral palsy can be treated and should not be ignored their orthodontic needs.

A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System (압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구)

  • Lee, Jang-Won;Lim, Woo-Sub;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • This research is to evaluate the fire extinguishing performance at a mixing ratio of pressurized air in the fire extinguishing system of compressed air foam (CAF) which injects compressed air into foam liquid and then discharging. The experimental device is made use of exclusive foam extinguishing facility for compressed air foam that is produces based on Canada National Laboratory and UL 162 standard, apply model of oil fire (B Class) 20 unit in accordance with "Standard of Model Approval and Product Inspection for Fire Extinguishing Agent" to the fire Extinguishing model. Compressed air is injected through the air mixture and study the tendency depending on increasing air foam ratio 1 : 4, 1 : 7, 1 : 10. In addition, the comparison experiments between synthetic surfactants foam and AFFF carry out with it at the air foam ratio 1 : 4. As a result, in the condition of same discharging flow, fire extinguishing effect of AFFF is the fastest at the air foam ratio 1 : 7 and the slowest at 1 : 10. Moreover, the fire extinguishing effect of AFFF in the comparison expeiments between AFFF and synthetic surfactants foam is faster than the other.

A Study on Measurement of Penetration Depth of Steel Pipe Using the Impact-Echo Method (충격탄성파법에 의한 강관구조물 근입깊이 측정에 관한 연구)

  • Lee, Sang Hun;Kumagai, Takayuki;Endo, Takao;Han, Youn Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.89-89
    • /
    • 2011
  • 도로의 가드레일 지주 근입깊이의 부족에 의한 자동차의 전락사고 이 후, 일본의 국토교통성 등의 관계자들이 그 대책 세우기에 부심해 왔으나, 기설 지주의 근입깊이를 측정할 수 있는 방법은 아직까지 알려져 있지 않으며, 현재로서는 작업의 전 과정을 비디오로 촬영하여 그 기록을 남기도록 되어있다. 그러나 그것은 상당히 비효율적인 작업으로 엄밀한 감시기능을 다하지 못하고 있으며, 감독자와 시공자의 양자로부터 계측 도구의 개발이 절실히 요구되고 있다. 일부의 초음파 측정기 업자가 가드레일 지주의 근입깊이를 측정할 수 있다고 주장하고 있으나, 시장에는 아직 나타나지 않고 있으며, 그 측정시스템의 측정여부와 성능의 검증이 이루어지지 않고 있는 상황이다. 지금까지 충격탄성파법 또는 초음파법을 이용하여, 매설된 가드레일 지주의 근입깊이를 측정한 성공사례가 정식으로 보고된 바는 없으며, 같은 강관주인 눈사태 방지책의 지주 파이프에 대한 근입깊이의 측정은 본 연구그룹의 의해 행하여진 바가 있다. 검사봉이나 해머 등으로 대상물을 두드려서 탄성파를 발생시키고, 그것을 가속도계 또는 속도계의 진동센서로 감지하여 그 파형을 분석함으로써 대상물의 치수 등을 측정하는 충격탄성파법은, 특히 콘크리트를 대상으로 공동 및 매설물 등의 탐사, 균열깊이의 측정 등에 폭 넓게 사용되고 있다. 하지만 이 측정방법을 가드레일의 지주의 근입깊이 측정에 적용할 경우, 일반적으로 행하여지는 방법, 즉 진동센서를 대상물의 상단부(캡)에 설치하는 방법으로는 접합부에 의한 탄성파의 손실과 캡의 휨 진동에 의한 노이즈 등을 해결하기가 곤란해진다. 또한 지반의 존재로 인한 진동 모드의 변화와 진동에너지의 감소 등의 문제점을 해결하지 않으면 안 된다. 본 연구는 충격탄성파법을 이용하여 지반에 설치된 눈사태 방지책이나 가드레일의 지주와 같은 강관 구조물의 근입깊이를 측정하고자 하는 연구이다. 이를 위해 진동센서를 캡이 아닌 측면부에 취부장치를 이용하여 설치함으로써 길이방향의 탄성파를 측정할 수 있도록 하고, 실제 구조물에 대해 측정을 실시하여 그 측정시스템의 성능과 유용성을 검토하고자 한다. 또한 다양한 길이의 실험용 강관 파이프를 매설하고 측정실험을 실시하여 측정시스템의 적용성에 대해서도 검토하였다. 본 연구를 통하여, 수신센서를 파이프의 측면에 선접촉하게 함으로서 종파를 감지하여 근입깊이를 포함한 파이프의 전 길이를 측정하는 본 측정시스템은 매설된 강관 구조물의 길이 측정에 기본적으로 적용 가능함을 확인할 수 있었다. 특히 오거 굴착으로 시공된 경우에는 높은 정도의 측정성능을 보여주었다. 또한 항타관입 파이프에 대해서는 지반의 영향을 고려함으로써 길이의 측정이 가능하다는 것을 확인할 수 있었다. 즉, 오거 굴착 또는 항타 관입 등 시공방법에 따라 측정결과에 대한 지반의 영향 정도가 달라지며 파형 분석 및 길이 산정시 그 영향을 고려하여야 함을 확인하였다.

  • PDF

Staticposture stability evaluation of female elderly using stability evaluation device (균형능력 평가 장치를 이용한 여성노인의 정적자세안정성 평가)

  • Kim, Tae-Hyung;Yi, Jae-Hoon;Oh, Seong-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5518-5524
    • /
    • 2011
  • The purpose of this study is to investigate the change of balance ability on aging by measuring balance ability of elderly females whose age is over 65. The subjects are ten elderly women (the mean age: 71.9) able to walk without assistants, the assistant equipments and drug dependence and ten young healthy women (the mean age: 23.2). We measured stability index (ST), Fourier index (F), weight distribution (WD), weight distribution index (WDI), synchronization index (SI) and fall index (FI) by using Tetrax (Tetra-ataxiometric Posturography). In result, STs and Fs at the low frequency region (F1) represented the significant difference between two groups at all postures with PO (pillow with eye open) exception (p<.01). Fs at the other frequency regions (F2~F8) represented the significant difference between two groups (p<.05). WDI of the elderly women represented the higher values than the young women at all postures but there are the significant difference at PO and PC (pillow with eye closed) only. These results may be due to age-related ability decline of somatesthesia, vestibular organ, central nervous system.

A Red Ginseng Internal Measurement System Using Back-Projection (Back-Projection을 활용한 홍삼 내부 측정 시스템)

  • Park, Jaeyoung;Lee, Sangjoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.10
    • /
    • pp.377-382
    • /
    • 2018
  • This study deals with internal state and tissue density analysis methods for red ginseng grade determination. For internal measurement of red ginseng, there have been various studies on nondestructive testing methods since the 1990s, It was difficult to grasp the most important inner hole and inside whites in the grading. So in this study, we developed a closed capturing device for infra-red illumination environment, and developed an internal measurement system that can detect the presence and diameter of inner hole and inside whites. Made devices consisted of infrared lights with a high transmission rate of red ginseng in 920 nanometer wave band, a infra-red camera and a Y axis actuator with a red ginseng automatically controlled focus on the camera. The proposed algorithm performs an auto-focus system on the Y-axis actuator to automatically adjust the sharp focus of the object according to the size and thickness. Then red ginseng is rotated $360^{\circ}$ at $1^{\circ}$ intervals and 360 total images are acquired, and reconstructed as a sinogram through Radon transform and Back-projection algorithm was performed to acquire internal images of red ginseng. As a result of the algorithm, it was possible to acquire internal cross-sectional image regardless of the thickness and shape of red ginseng. In the future, if more than 10,000 different shapes and sizes of red ginseng internal cross-sectional image are acquired and the classification criterion is applied, it can be used as a reliable automated ginseng grade automatic measurement method.