• Title/Summary/Keyword: 검사장치

Search Result 1,049, Processing Time 0.03 seconds

Sonographer's Job Stress and its Effects on Job Satisfaction: Focused on Busan and Ulsan (초음파 검사자의 직무 스트레스가 직무만족도에 미치는 영향: 부산, 울산지역을 중심으로)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.263-271
    • /
    • 2017
  • The purpose of this study was to investigate the relationship between general characteristics, job stress and job satisfaction of 150 sonographer working in Busan and Ulsan area and to identify the predictors of job satisfaction. As a result, the higher the age, experienced job change, the more job satisfaction increased. The sub-factors of job stress and job satisfaction are significantly negative correlated with organizational system, lack of reward, occupational climate, job insecurity, insufficient job control, job demand. The most influential variables in job satisfaction were organizational system and lack of reward. Therefore in order to increase the job satisfaction of the sonographer, it is important to establish and institutional device related to effective organization, manpower management and compensation to reduce job stress.

Lung Lobe Torsion with Concurrent Intestinal Lymphangiectasia in a Maltese Dog (Maltese 개에서 림프관 확장증을 동반한 폐염전 발생 증례)

  • Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.262-266
    • /
    • 2011
  • A 4-year-old intact male, Maltese dog weighing 2.2 kg was presented for evaluation of tachypnea and hyperthermia. On initial evaluation, the dog was dyspneic, but alert and responsive. Muffled heart sound was noted with auscultation of the right hemithorax. The radiographic findings were consolidation of the right middle lung lobe, pleural effusion, and abdominal fluid accumulation. Thoracic computed tomography confirmed a contrast-enhancing mass within the right middle lung lobe. Surgical exploration of the thoracic cavity was performed using a right fifth intercostal thoracotomy. Examination of the right lung lobe revealed $360^{\circ}C$ torsion of the right middle lung lobe at the level of the hilus, in a clockwise direction. Lung lobectomy was performed using a thoracoabdominal stapling device with 2.5-mm vascular staples. Full-thickness intestinal biopsy by exploratory laparotomy was taken from the jejunum for histological assessment. Histopathologic examination of the full-thickness intestinal biopsy revealed distended lacteal located within the submucosa of the jejunum. Intestinal lymphangiectasia was resolved with prednisone and low fat diets. Subsequent communication with the owner revealed that the patient was in good health 6 months post-discharge.

A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test (Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구)

  • Lee, B.J.;Seo, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.228-236
    • /
    • 1995
  • In this paper the method to evaluate shielding deficiency by gamma scanning test was presented and verified theoretically by Monte Carlo code which is one of the best effective method for radiation shielding calculation. The cylindrical shielding model was selected to evaluate shielding deficiency by gamma scanning test. First, the reference shielding according to the design requirement of cask was fabricated specially and reference values were measured with Co-60 source and scintillation detector. As a result with which calculated the reference values, it is shown that maximum deficiency thickness for lead of true cylindrical shielding model was 12mm. To verify this, thickness of lead was calculated by MCNP code and maximum deficiency thickness was 11.6mm. The experimental result obtained by the use of reference shielding was in good agreement with the theoretical result within 4.1%. So, this method can be applied to inspect the shielding ability for great shielding or cask which the radioactive material is used. To perform measurement more exactly, the further work on the development of measuring equipment to display the results on the screen will be required.

  • PDF

Thermographic Evaluation of Beating Process of Experimentally Induced Infectious Arthritis in Horses (실험적으로 유발한 말 감염성 관절염의 치유경과에 대한 체열학적 평가)

  • Yang Young-Jin;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.22-30
    • /
    • 2006
  • This study was carried out to assess the usefulness of thermography for diagnosis and healing process of musculoskeletal disorder in horses. Horses with experimentally induced infectious arthritis were treated with bee venom or antibiotics for 5 weeks from 24 hours after inoculation of Staphylococcus aureus, the effectiveness of the 2 therapeutic drugs treatment was similar to each other. Thermographic evaluation was similar to any other tests, because the thermal pattern tend to return to normal with declining similar to those of clinical signs, laboratory experiments and healing of the lesion. This ability to assess inflammatory change noninvasively make thermography an ideal imaging tool to aid in the diagnosis of certain lameness condition or musculoskeletal disease in horses. These results suggested that thermographic evaluation in horses with musculoskeletal disorders were useful for diagnosis and helpful for monitoring of healing process.

Inspection System for Tracing Defects of Optical Film Using Contact Image Sensor (Contrast 향상 필름 평가를 위한 실시간 검사장치 개발)

  • Rhee, Hyug-Gyo;Jeon, Byeong-Hyug;Lee, Hoi-Yun;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.310-314
    • /
    • 2008
  • The light from the exterior considerably deteriorates the performance of displays including PDP (plasma display panel). Thus semi-conductor industries have developed a special optical film that can block or absorb the exterior light. In this paper, we propose a new inspection system for tracing the defects of the film. Our system is able to inspect a $1.5\;m\;{\times}\;1\;m$ area for 10 sec with $127\;{\mu}m\;{\times}\;50{\mu}m$ spatial resolution.

A Study on the Setting of Examination Limits for Radiographers in Medical Institutions (의료기관 내 방사선사의 검사 한도 설정에 관한 연구)

  • Jeong-Ho Kim;Gap-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.401-410
    • /
    • 2023
  • A radiographer is a job in charge of diagnostic imaging equipment, and must contribute to the promotion of public health by suggesting an appropriate level of work. To this end, we intend to present an appropriate level of work through evaluation of human harm according to work, statistical evaluation through questionnaires, and domestic and international trends. In the case of human harm evaluation, considering radiation exposure, 42.6%, shield work, 69.7%, and in the case of magnetic resonance imaging, the maximum length of stay in the examination room should be adjusted to 15 minutes and not exceed 30 times. According to the survey statistics, it was confirmed that the physical and mental burden increased due to the high workload and difficulty compared to working hours. Based on domestic and international trends, it is necessary to adjust the examination standards for domestic radiographers to 36.8% to promote national health through qualitative improvement of radiological examinations. something to do.

Performance Verification and Reliability Test of Tunnel Shotcrete Stressmeter (터널 숏크리트 응력계의 성능검증과 신뢰성 시험 연구)

  • Kim, Yeong-Bae;Park, Yeong-Bae;Lee, Seong-Won;Lee, Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.4
    • /
    • pp.113-126
    • /
    • 2024
  • Shotcrete lining is an important material for the stability of tunnels in NATM tunnels. However, stressmeters for stress measurements of shotcrete lining are installed in the field without performance verification because of a lack of research on methods, procedures, regulations, and reliability of measurement equipment. To solve this problem, all shotcrete stressmeters currently used in Korea were investigated. For each stressmeter, external inspection and structural and functional inspection were performed to identify defects and problems in devices. For this purpose, a shotcrete stressmeter performance test device capable of load loading in stages was developed and obtained KOLAS certification. Using the device, stressmeter performance tests were conducted. Structural problems of integrated- and cell-type shotcrete stressmeters were identified through concrete mold tests, and improvement plans and performance verification procedures were suggested. The results of this study are expected to contribute to the preparation of regulations for the performance verification of shotcrete stressmeters and the selection of measuring instruments in the field in the future.

Development of Interface Inspection System for On-board Signal Equipment (열차 차상신호 인터페이스 검사 시스템 개발)

  • Park, Jae-Young;Lim, In-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2324-2329
    • /
    • 2014
  • The inspection of distance to go train control system conducted only when train is in main line or inspecting line, that affects low work efficiency and hazard elements to safe operation. Before or after train operation, the interface test between on-board and wayside signal system must be conducted. In this paper, onboard signal interface inspection system based on the real-time automatic analysis of onboard system status information that is transmitted to the wayside system and the operation status check of the onboard signal device operates as a virtual train information that is transmitted to the onboard system have been proposed. And after building the inspection system to the inspecting track of Daejeon Subway Line 1, Panam Depot, the verification algorithm of proposed interface test and the results was presented. therefore, it has enhanced work efficiency to do not carry train operation of a half hour in test line to test on-board system.

A Study on the Thermal Coefficient Measurements of Special Steel by ESPI at High Temperature (고온에서 ESPI에 의한 특수강의 열팽창계수 측정에 관한 연구)

  • Kim, K.S.;Yang, S.P.;Kim, H.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.20-30
    • /
    • 1993
  • Electric Speckle Pattern Interferometry (ESPI) using a CW-laser, a video system and an image processor was applied to the thermal coefficient measurements on free thermal expansions at high temperatures : ESPI provides the distribution of in-plane displacement resolved in a preselected direction. ESPI retains the merits of little or no surface preparation, no contact with the surface and the real-time presentation of interference fringes. Appling ESPI at high temperatures, several problem which caused the reduction of fringe visibility were encountered. The problem on the turbulence in the hot air surrounding high temperature objects will be solved by using a vacuum chamber. The background radiations from the objects were suppressed considerably by an interference filter. The problem on the oxidation of the object surface could't be solved. The interference fringe, whose spacings were calculated by FFT to avoid human error, were observable up to $800^{\circ}C$. The results measured by ESPI were nearly equal to the data which have already been published, up to about $800^{\circ}C$.

  • PDF

Block based Smart Carving System for Forgery Analysis and Fragmented File Identification

  • Lee, Hanseong;Lee, Hyung-Woo
    • Journal of Internet Computing and Services
    • /
    • v.21 no.3
    • /
    • pp.93-102
    • /
    • 2020
  • In order for data obtained through all stages of digital crime investigation to be recognized as evidence capability, it must satisfy legal / technical requirements. In this paper, we propose a mechanism and implement software to provide digital forensic evidence by automatically recovering files by scanning / inspecting the unallocated area inside the storage disk block without relying on information provided by the file system. The proposed technique checks / analyzes the RAW disk data of the system under analysis in 512-byte block units based on information on the storage format / file structure of various files stored on the disk without referring to the file system-related information provided by the operating system. The file carving process was implemented, and a smart carving mechanism was proposed to intelligently restore deleted or damaged files in the storage device. As a result, we have provided a block based smart carving method to intelligently identify fragmented and damaged files in storage efficiently for forgery analysis on digital forensic investigation.