Fractionated Stereotactic Radiation Therapy for Intracranial Benign Tumor : Preliminary Results of Clinical Application (양성 뇌종양의 분할정위 방사선치료 : 임상적 응용의 예비적 결과)

  • Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Choi Dong Rak;Nam Jong Hyun;Lee Jung Il;Park Kwan;Nam Do-Hyun;Kim Moon Kyung
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.185-194
    • /
    • 1998
  • Purpose : With the development of stereotactic immobilization systems capable of reliable serial repositioning, fractionated stereotactic radiation therapy (FSRT) offers the Potential for an improved treatment outcome by excellent dose delivery, and dose distribution characteristics with the favorable radiobiological properties of fractionated irradiation. We describe our initial experience using FSRT for the treatment of intracranial benign tumor. Materials and Methods : Between August 1995 and December 1996. 15 patients(7 males and 8 females aged 6-70 years) were treated with FSRT. The patients had the following diagnosis pituitary adenoma(10) including one patient who previously had received radiotherapy, craniopharyngioma (2), acoustic neurinoma (1), meningioma (2). Using the Gill-Thomas-Cosman relocatable head frame and multiple non-coplanar therapy, the daily dose of 2Gy was irradiated at 90% to 100% isodose surface of the isocenter The collimator sizes ranged from 26mm to 70mm. Results : In all patients except one follow-up lost, disease was well-controlled. Acute complication was negligible and no patient experienced cranial nerve neuropathies and radiation necrosis. In overall patient setup with scalp measurements, reproducibility was found to have mean of $1.1{\pm}0.6mm$ from the baseline reading. Conclusion : Relocatable stereotactic system for FSRT is highly reproducible and comfortable. Although the follow-up period was relatively short. FSRT is considered to be a safe and effective radiation technique as the treatment of intracranial tumor. But the fractionation schedule(fraction size, overall treatment time and total dose) still remains to be solved by further clinical trials.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Development of Heated-Air Dryer for Agricultural Waste Using Waste Heat of Incineration Plant (소각장 폐열을 활용한 농업폐기물 열풍 건조장치 개발)

  • Song, Dae-Bin;Lim, Ki-Hyeon;Jung, Dae-Hong
    • Journal of agriculture & life science
    • /
    • v.53 no.5
    • /
    • pp.137-143
    • /
    • 2019
  • To manufacturing of solid fuel by reuse of the wastes, the drying unit which have 500 kg/hr of drying capacity was developed and experimentally evaluate the performance. The spinach grown in Nam-hae island were used for the experiments and investigated of the heated-air drying characteristics as the inlet amount of raw materials, raw material stirring status, conveying type and drying time. The drying air heated by the energy derived from the steam which is supplied from the incineration plant. The moisture contents of raw materials were measured 85.65%. The inlet flow rate of drying air made a difference as the depth of the raw materials loaded on the drying unit and temperature has showed 108~144℃. The drying speed of the mixed drying more than doubled as that of non mixed drying under the same drying type, inlet amount, drying time and drying air temperature. In each experiment, the drying capacity have showed over 500 kg/hr. A drying efficiency of the ratio of drying consumption energy to input energy was 33.46%, lower than the average of 57.76% for the 157 conventional dryers. Because developed dryer must have a drying time of less than one hour, it is considered that the dry efficiency has been reduced due to the loss of wind volume during drying. If waste heat from incineration plant is used as a direct heat source, the dry air temperature is expected to be at least 160℃, greatly improving the drying capacity.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$ (직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과)

  • Kim, Jong-Hoon;Oh, Do-Hoon;Kang, Ki-Moon;Kim, Woo-Cheol;Kim, Won-Dong;Kim, Jung, Soo;Kim, June-Sang;Kim, Jin-Hee;Kil, Hak-Jae;Suh, Chang-Ok;Sohn, Seung-Chang;Ahn, Yong-Chan;Yang, Dae-Sik
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.22-31
    • /
    • 2005
  • Purpose : To conduct a nationwide survey on the principals in radiotherapy for rectal cancer, and produce a database of Korean Patterns of Care Study. Materials and Methods : We developed web-based Patterns of Care Study system and a national survey was conducted using random sampling based on power allocation methods. Eligible patients were who had postoperative radiotherapy for rectal cancer without gross residual tumor after surgical resection and without previous history of other cancer and radiotherapy to pelvis. Data of patients were Inputted to the web based PCS system by each investigators in 19 institutions. Results : Informations on 309 patients with rectal cancer who received radiotherapy between 1998 and 1999 were collected. Male to female ratio was 59 : 41, and the most common location of tumor was lower rectum ($46\%$). Preoperative CEA was checked in $79\%$ of cases and its value was higher than 6 ng/ml in $32\%$. Pathologic stage were I in $1.5\%$, II in $32\%$, III in $53\%$, and IV in $1.6\%$. Low anterior resection was the most common type of surgery and complete resection was peformed in $95\%$ of cases. Distal resection margin was less than 2 cm in $30\%$, and number of lymph node dissected was less than 12 in $31\%$. Chemotherapy was peformed in $91\%$ and most common regimen was 5-FU and leucovorine ($59\%$). The most common type of field arrangement used for the initial pelvic field was the four field box (Posterior-Right-Left) technique ($65.0\%$), and there was no AP-PA parallel opposing field used. Patient position was prone in $81.2\%$, and the boost field was used in $61.8\%$. To displace bowel outward, pressure modulating devices or bladder filling was used in $40.1\%$. Radiation dose was prescribed to isocenter in $45.3\%$ and to isodose line in 123 cases ($39.8\%$). Percent delivered dose over $90\%$ was achieved in $92.9\%$. Conclusion : We could find the Patterns of Care for the radiotherapy in Korean rectal cancer patients was similar to that of US national survey. The type of surgery and the regimen of chemotherapy were variable according to institutions and the variations of radiation dose and field arrangement were within acceptable range.

Effect of Nasal Continuous Positive Airway Pressure after Early Surfactant Therapy in Moderate Respiratory Distress Syndrome (중등도 신생아 호흡 곤란 증후군에서 폐 표면 활성제 조기 투여 후 Nasal CPAP의 치료 효과)

  • Kim, Eun Ji;Kim, Hae Sook;Hur, Man Hoe;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.10
    • /
    • pp.1204-1212
    • /
    • 2002
  • Purpose : Early surfactant therapy with either gentle ventilation, high-frequency ventilation or aggressive weaning of mechanical ventilation are principles for the treatment of respiratory distress syndrome(RDS). We studied to determine the accessibility of noninvasive nasal continuous positive airway pressure(CPAP) rather than mechanical ventilation by invasive intubation after early surfactant therapy. Methods : The study group consisted of 14 infants who were born and diagnosed with moderate respiratory distress syndrome and received early surfactant therapy with nasal CPAP of PEEP 5-6 cm $H_2O$ within two hours after birth in the Fatima neonatal intensive care unit for two years from January 1999 to August 2001. The control group consisted of 15 infants who were diagnosed with the disease and could be weaned from mechanical ventilator within five days after birth during the same period. Results : The characteristics, the severity of clinical symptoms and laboratory findings in the two groups at birth showed no significant difference. Neither did the interim analysis of laboratory data in two groups. Of 14 infants in the study group who received nasal CPAP after early surfactant therapy, only two infants showed weaning failure with this therapy. In the response cases, duration of CPAP was five days and mean airway pressure was $5.4{\pm}0.5cm$ $H_2O$. Two had the complication of CPAP with abdominal distension. Final complications and outcomes in the two groups showed no signifcant difference(P>0.05). Conclusion : The clinical courses in the two groups showed no significant difference. Therefore, we suggest that early surfactant therapy with noninvasive nasal CPAP is a simple and safe method rather than aggressive weaning after invasive mechanical ventilation in moderate respiratory distress syndrome.

A Monitoring of Aflatoxins in Commercial Herbs for Food and Medicine (식·약공용 농산물의 아플라톡신 오염 실태 조사)

  • Kim, Sung-dan;Kim, Ae-kyung;Lee, Hyun-kyung;Lee, Sae-ram;Lee, Hee-jin;Ryu, Hoe-jin;Lee, Jung-mi;Yu, In-sil;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.267-274
    • /
    • 2017
  • This paper deals with the natural occurrence of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in commercial herbs for food and medicine. To monitor aflatoxins in commercial herbs for food and medicine not included in the specifications of Food Code, a total of 62 samples of 6 different herbs (Bombycis Corpus, Glycyrrhizae Radix et Rhizoma, Menthae Herba, Nelumbinis Semen, Polygalae Radix, Zizyphi Semen) were collected from Yangnyeong market in Seoul, Korea. The samples were treated by the immunoaffinity column clean-up method and quantified by high performance liquid chromatography (HPLC) with on-line post column photochemical derivatization (PHRED) and fluorescence detection (FLD). The analytical method for aflatoxins was validated by accuracy, precision and detection limits. The method showed recovery values in the 86.9~114.0% range and the values of percent coefficient of variaton (CV%) in the 0.9~9.8% range. The limits of detection (LOD) and quantitation (LOQ) in herb were ranged from 0.020 to $0.363{\mu}g/kg$ and from 0.059 to $1.101{\mu}g/kg$, respectively. Of 62 samples analyzed, 6 semens (the original form of 2 Nelumbinis Semen and 2 Zizyphi Semen, the powder of 1 Nelumbinis Semen and 1 Zizyphi Semen) were aflatoxin positive. Aflatoxins $B_1$ or $B_2$ were detected in all positive samples, and the presence of aflatoxins $G_1$ and $G_2$ were not detected. The amount of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in the powder and original form of Nelumbinis Semen and Zizyphi Semen were observed around $ND{\sim}21.8{\mu}g/kg$, which is not regulated presently in Korea. The 56 samples presented levels below the limits of detection and quantitation.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF