• Title/Summary/Keyword: 검사시기

Search Result 736, Processing Time 0.031 seconds

Improvement of Inspection Methods using Lighting Signals and Guidebook for Non-English speaking Foreign Visitors (For chest X-ray Screening Examinees) (비영어권 외국인 내원객의 조명 신호와 안내서를 이용한 검사방법 개선 효과(흉부 방사선 검사자를 대상으로))

  • Kwak, Jong Hyeok;Choi, Min Gyeong;Kim, Neung Kyun;Kim, A Yeon;Kim, Gyeong Rip
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.577-584
    • /
    • 2020
  • In this study, the number of non-English speaking visitors is increasing day by day, and accordingly, there was a limitation in language communication and communication during radiographic examination. To this end, after distributing the handbook produced for inspection, the improvement effect of before and after explanation was examined. The score scale was not statistically significant as to whether it was the test site or not, and the degree of discomfort of the test, the degree of understanding of the breathing guidelines, and the satisfaction of the test description were improved and the score scale was improved before and after the description of the guide. Non-English-speaking foreign visitors were more satisfied with explanations in their own text than in English or Korean, and the method was also able to conduct effective inspections by informing the foreign guests when to control their breathing by using the lighting signals in the laboratory. In the future, the quality of medical services and imaging medical examinations can be improved only when communication methods are implemented from various perspectives, such as developing various language interpretation programs, developing guides for various test sites, and developing tools and improving foreign language skills of radiologists and medical staff. There will be. In the future, it may be used as a basic resource to prepare a manual that can be used to examine non-English speaking foreigners who do not understand English or Korean in other radiology labs.

Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

A Study of Optimal Maintenance Schedules of a System under the Periodic Inspection Policy (주기적인 검사 정책하에서 최적예방 교체시기 결정에 관한 연구)

  • 정현태;김제승
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.263-271
    • /
    • 1997
  • This paper presents a preventive maintenance model for determining the preventive replacement period of a system in which a failure rate is affected by the cumulative damage of fault and inspection. Especially, the failure rate function is considered to be a function of the cumulative damage of the fault and inspection time. Types of replacement considered are preventive replacement and failure replacement. Failure rate and expected cost function between replacement are derived. An optimal policy is obtained that minimizes the average cost per unit time for preventive replacement, failure replacement, inspection and repair.

  • PDF

STEP AP214 Core Data for Automotive Design and Processes

  • Yong, Jeong-Yoon
    • Proceedings of the CALSEC Conference
    • /
    • 1997.11a
    • /
    • pp.427-441
    • /
    • 1997
  • ㆍEXPRESS에 의한 AP214 Schema 정의 ㆍEXPRESS에 의한 Entity 정의 ㆍEXPRESS에 의한 TYPE, FUNCTION, RULE의 정의 ㆍAIM 축소 정보 모델 (Subset) 구성 ㆍAIM 축소 정보 모델의 예 ㆍ축소 정보 모델에 근거한 소규모 PDM시스템 AP214 개요 정식 명칭 : Core Data for Automotive Design and Processes 파트 번호 : ISO 10303-214 제안시기 : 1992년 STEP 시애틀 회의 (독일에 의하여 제안) 대상 내용 : 자동차의 기획 단계로부터 스타일링, 설계, 실험, 공정 계획, 툴 설계 및 제작, 품질 검사에 이르는 수명 전 주기상에 발생되는 제품 관련 정보 현 상태 : CD(Committee Draft) DIS (Draft International Standard) 표결 진행중(중략)

  • PDF

전기설비의 검사, 점검 및 시험④

  • Gwon, Sun-Gu;Kim, Gi-Uk;Lee, Gyu-Bok
    • Electric Engineers Magazine
    • /
    • v.242 no.10
    • /
    • pp.19-23
    • /
    • 2002
  • 월차점검 및 정기점검 등에서 점검, 시험의 결과, 지급수리 혹은 개수를 필요로 하는 곳을 발견하였을 때는 설치자에게 그 취지를 설명하고 개수를 설정함과 함께 대행의 경우 자가용전기설비에 관한 통보서 2통을 만들어 1통은 설치자에게 제출하고 1통은 설치자의 확인을 받아 전기안전관리사 등이 보관하고 불량개소 등의 개수, 개선에 노력하고 사고의 미연방ㅈ를 도모하는 것이 전기안전관리사 등의 중대한 임무의 하나로 생각하여 시기가늦어지지 않도록 실행하여야 한다

  • PDF

Objective Visual Acuity Test Using Nystagmus (Nystagmus를 이용한 객관적 시기능 검사에 관한 연구)

  • 이인범;김민섭;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.103-105
    • /
    • 2000
  • Optokinetic nystagmus(OKN) testing is an useful tool for assessment of human visual function. Specially, this method has been used for assessing visual function in infants and malingering patients. OKN drum and OKN tape are the common devices currently used for clinical cases. In this paper, we present newly the automated and computerized method for the quantitative and objective assessment of visual acuity in OKN testing.

  • PDF

청각장애 아동의 청각통합 능력과 언어능력과의 상관관계 연구

  • 박상희;권영주
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.239-239
    • /
    • 2003
  • 연구목적 : 본 연구의 목적은 청각장애 아동들이 실제적으로 소리를 듣는 능력과 말소리를 이해하고 표현하는 언어 능력과 어떠한 관계가 있는가에 대해서 알아보고자 하는데 있다. 일반적으로 청각통합 능력은 청각장애 아동의 듣기 능력을 측정할 수 있는 대표적인 검사도구이며, MCDI-K는 부모가 언어능력을 평가할 수 있는 도구이다. 이 두 가지 모두 부모가 평가할 수 있는 도구이다. 따라서 본 연구에서는 청각통합 능력, 언어이해능력, 언어표현능력이 연령과 교육받은 시기와 어떠한 관계가 있는 가 알아보기 위해서 실시하였다. (중략)

  • PDF

A case of neonatal peroneal neuropathy with intrauterine onset (신생아 종아리신경병증 1례)

  • Lee, Sang-Soo;Sim, Ji-Yun;Kim, Mi-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.6
    • /
    • pp.585-587
    • /
    • 2007
  • Peroneal neuropathy presenting at birth is a rare disorder. Although neonatal mononeuropathies may be related to obstetrical complications, prenatal mechanisms should be also considered. We describe an infant who was born at term by cesarean section due to breech presentation with a unilateral footdrop. Lack of compound muscle action potential in the peroneal nerve and denervation potentials confined to the tibialis anterior and the extensor hallucis longus muscles in the electrophysiological studies on the fourth day of life strongly suggest an isolated peroneal neuropathy of intrauterine onset. Early and sequential electrodiagnostic studies will be important to provide better temporal and pathophysiologic definitions, the better timing of onset and prognosis for mononeuropathies presenting in newborn infants.

Activities to Reduce the number of No-Show Patients with Colonoscopy appointments (대장내시경 검사 부도관리를 위한 개선활동)

  • Kwon, Oh-Ryoun;Lee, Jung-Sun;Na, Eun-Shim;Kim, Hoon
    • Quality Improvement in Health Care
    • /
    • v.15 no.1
    • /
    • pp.89-100
    • /
    • 2009
  • 문제: 소화기병검사실에서 대장내시경 검사의 부도건수가 최근 월 200명 정도로 예약인원의 16%에 달한다. 이는 본원 외래진료 부도율이 평균 10%인 것과 비교할 때 상당히 높은 결과이므로 대장내시경 예약환자를 대상으로 부도율 관리를 위한 활동이 필요하였다. 목적: 외래 및 입원환자의 부도건수 및 부도환자의 특성을 분석하고, 개선활동을 통하여 대장내시경 검사의 부도율을 줄인다. 의료기관: 서울 아산병원. 질 향상 활동: 부도관리를 위한 개선활동으로 SMS 횟수를 2주전, 4일전, 1일전 3회로 변경하고, 내용도 각 시기마다 차별화하였다. 대장내시경 검사 예약을 하고 기다리는 환자를 대상으로 처방일 순, 예약 날짜순서 등 필요한 항목 순으로 볼 수 있는 리스트가 필요하여 예약대기 프로그램을 개발하였고, 처방일로부터 2주 이내 자동예약을 금지하였다.(7월 10일부터 시작) 예약대기명단에 있는 환자를 대상으로 전화로 예약 변경을 하여 2주 이내에는 예약의 빈자리가 없도록 하였다. 미리 부도를 예측하여 추가로 예약하던 방법에서 정원조정을 하여 정원 외 추가 예약을 하지 않았다. 입원환자 일정관리를 위하여 일정관리 프로그램을 개발하여 타과의뢰 회신을 하는 전임의가 직접 날짜를 전산에 입력하여 회신과 동시에 검사실, 담당주치의, 담당 간호사가 모두 일정을 확인할 수 있도록 하였으나 프로그램이 늦어져 9월 12일부터 시행하였다. 개선효과: 부도건수가 개선 전 8주 동안 385건(예약인원 대비 16%) 에서 개선 후 6주의 평가기간 동안 256건(예약인원대비 14.1%)으로 129건이 감소하였으며, 검사 1-2일전 일정 변경 연락 환자 감소 및 검사 비용 수납 환자의 부도건수가 감소하였다. 대장내시경 검사 예약대기 프로그램 운영 및 예약 변경 전화 활동으로 2달씩 기다리던 환자의 예약일을 약 한 달 정도 단축하여 줄 수 있었다. 검사 정원 관리의 결과로 검사 예약 시 예약기준이 명확해지고, 부적절한 예약으로 인한 검사지연 등이 확실히 줄었다. 또한 입원환자 일정관리 프로그램 적용으로 입원환자의 검사일정과 관련된 전화업무는 확실히 줄어들 것으로 예상된다.

  • PDF

Reliability of Infrared Thermographic Imaging in the Orofacial Region (구강안면부에서 적외선 체열검사의 신뢰도에 관한 연구)

  • Han, Dong-Joon;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.355-367
    • /
    • 2001
  • 치의학 분야에서 디지탈 근적외선 체열측정 장치(digital infrared thermographic imaging; DITI)의 응용이 미미한 것은 과거 열측정장치의 기술력이 부족한 것이 주된 요인이었다. 그러나 최근들어 기술이 진보함에 따라 실시간 열영상을 재현할 수 있게 되었고 이는 치의학 및 의학계에 많은 관심을 일으키고 있다. 지금까지의 연구를 보면 두개하악장애시 구강영역의 온도변화의 임상적 효용 가능성을 제시하였으나 안면 및 두경부에 대한 실제 기기 및 측정방법의 신뢰도에 대한 연구는 이루어지지 못한 상태이다. 본 연구에서는 DITI에 대한 신뢰도를 조사하였다. DITI의 모니터 상에서 비활동성 발통점의 부위를 찾아내기가 쉽지 않다. 따라서 모니터상에서 안면발통점(joint, temporalis anterior, masseter anterior, masseter inferior)의 부위를 찾아 온도를 찾아내는 방법과 미리 발통점 피부상에 링모양의 마크를 부착하여 모니터상에서 쉽게 찾아내는 방법을 사용하여 신뢰도를 조사하여 비교한 결과 다음과 같다. 1. 조사한 발통점 중에서 temporalis anterior, joint, masseter anterior과 masseter inferior의 순서로 피부온도가 유의하게 온도가 높았으나(p<0.05) masseter 내에서는 유의한 차이를 보여주지 않았다. 2. 4개의 발통점 모두에서 높은 열적 대칭성을 보였으며, 좌우 온도차이는 $0.1^{\circ}C$미만이었다. 3. 다른 시기에 조사한 조사자내 신뢰도는 두 조사자 모두 높은 상관관계를 보여주지 않았으며 대조군과 마크를 사용한 군간에는 뚜렷한 차이를 볼 수 없었다. 4. 동일한 시기에 조사한 조사자간 신뢰도는 두 시기 모두 joint 부위의 일부를 제외하고 높은 상관관계를 보여주었으며, 마크를 사용한 경우 사용하지 않은 경우 보다 훨씬 신뢰도가 높은 상관관계를 나타내었다. 이상의 결과로 보아 DITI는 두개하악장애환자에 대한 두경부 발통점의 온도변화를 측정하는 데 있어 시간에 따른 신뢰도는 결여되었으나 동일 시기의 측정에는 매우 유익할 것으로 사료되며, 특히 발통점에 대한 표시를 사용하는 경우 매우 정확한 온도를 조사할 수 있을 것으로 판단된다.

  • PDF