• Title/Summary/Keyword: 검량선

Search Result 264, Processing Time 0.018 seconds

Development of LC-MS/MS analytical methods for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai (LC-MS/MS를 이용한 생약 백출 및 우슬 중 Metalaxyl 잔류분석법 개발)

  • Yun, Myung-Sub;Yang, Seung-Hyun;Choi, Hoon
    • Journal of Applied Biological Chemistry
    • /
    • v.65 no.1
    • /
    • pp.17-21
    • /
    • 2022
  • A new rapid and simple method for metalaxyl in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai has been developed and validated. This study was conducted to develop a method for analyzing metalaxyl by a method based on QuEChERS using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Samples were extracted with acetonitrile and purified using amino-propyl (NH2) Solid Phase Extraction cartridge. The method limit of quantitation (MLOQ) was 0.01 mg/kg. The linearity of matrix-matched calibration curve (r2) was ≥0.99 at the calibration range of 0.001-0.05 mg/kg. For recovery test, Atractylodes macrocephala Koidzumi or Achyranthes japonica Nakai was treated with standard solutions at MLOQ and 10MLOQ levels. Recovery rates were in the range of 88.1-109.1% with <5.5% coefficient of variation. This established analytical method was fully validated. Based on these results, it can contribute to improving the safety of residual pesticides in Atractylodes macrocephala Koidzumi and Achyranthes japonica Nakai.

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.

Development of a Residue Analysis Method for Metamifop in Paddy Water, Soil, and Rice with HPLC (HPLC를 이용한 농업용수, 논토양, 및 현미 중 metamifop의 잔류분석법 개발)

  • Park, Hee-Woon;Moon, Joon-Kwan
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.68-74
    • /
    • 2017
  • An analytical method for detecting metamifop residue in paddy water, soil, and rice with high performance liquid chromatography (HPLC) was developed. Water was extracted with ethyl acetate before analyzing by HPLC. Soil residues were extracted with acetone under acidic condition and after purifying with $Extrelut^{(R)}$ NT, and silica SPE, the residue was analyzed by HPLC. For residue analysis in rice, the procedure involved extraction with acetone, purification with $Extrelut^{(R)}$ NT, partitioning between acetonitrile/hexane, purification with silica SPE cartridge, and analysis by HPLC. The limit of detection (LOD) was 1.0 ng, limit of quantitation (LOQ) was 3.0 ng, and method limit of quantitation (MLOQ) were 0.001 mg/L for paddy water, 0.01 mg/kg for rice and soil, respectively. Standard calibration curve shows linearity from 0.05 mg/kg to 5.0 mg/kg ($R^2=0.9999$). The recoveries in fortified paddy water were $91.3{\pm}3.5%$ (0.01 mg/L level) and $93.2{\pm}6.3%$ (0.05 mg/L level). The recoveries in fortified paddy soils were $92.5{\pm}4.0%$ (0.1 mg/kg level) and $92.7{\pm}4.0%$ (0.5 mg/kg level) in soil A, while, $102.3{\pm}4.4%$ (0.1 mg/kg level) and $98.9{\pm}7.9%$ (0.5 mg/kg level) in soil B, respectively. The recoveries in fortified rice were $93.0{\pm}6.9%$ (0.1 mg/kg level) and $85.0{\pm}3.5%$ (0.5 mg/kg level). This method was proved to be effective and can be used to determine the metamifop residue in paddy water, paddy soil, and rice.

Quantitative Analysis of Vitamin B5 and B6 Using High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 비타민 B5 및 B6의 정량 분석)

  • Kim, Gi-Ppeum;Hwang, Young-Sun;Choung, Myoung-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.10
    • /
    • pp.1186-1194
    • /
    • 2017
  • Recently, many people have demanded reliable nutritional data even for minor-components. On the other hand, an analytical method for the analyses of vitamin $B_5$ and $B_6$ is lacking. Therefore, this study attempted to validate with accuracy and precision the analysis of vitamin $B_5$ and $B_6$ using a high-performance liquid chromatography (HPLC) method. The vitamin $B_5$ and $B_6$ contents were analyzed using an Agilent 1260 series HPLC system. YMC-Pack ODS-AM ($250{\times}4.6mm$ I.D.) and YMC-Pack Pro RS $C_{18}$ ($250{\times}4.6mm$ I.D.) columns were used for the analyses of vitamin $B_5$ and $B_6$, respectively. In the case of vitamin $B_5$, the flow rate was set to 1.0 mL/min by isocratic elution using the 50 mM $KH_2PO_4$ solution (pH 3.5)/acetonitrile (ACN) (95:5, v/v) with monitoring at 200 nm using HPLC/DAD, whereas the flow rate for vitamin $B_6$ was set to 1.0 mL/min of flow rate by isocratic elution using a 20 mM $CH_3CO_2Na$ solution (pH 3.6)/ACN (97:3, v/v) with monitoring by excitation at 290 nm and emission at 396 nm using HPLC/FLD. The column temperature was set to $30^{\circ}C$. The injection volume was $20{\mu}L$ for each experiment. The specificity of the accuracy and precision for vitamin $B_5$ and $B_6$ were also validated by HPLC. The results showed high linearity in the calibration curve for vitamin $B_5$ ($R^2=0.9998^{{\ast}{\ast}}$), the limit of detection (LOD) and limit of quantitation (LOQ) were 0.4 mg/L and 1.3 mg/L, respectively, In contrast, for the calibration curve of vitamin $B_6$, which showed high linearity ($R^2=0.9999^{{\ast}{\ast}}$), the LOD and LOQ were 0.006 mg/L and 0.02 mg/L, respectively.