Anodic oxidation reaction was applied to remove trihalomethanes in an aqueous solution. Each component was determined by using solid phase microextraction(SPME) fiber and GC-ECD. Anodic and cathodic compartments were separated in order to protect contaminants and connected by $KNO_3$-agar bridge. The calibration graphs of the 6 THM components were shown good linearlity from a few ppb up to a few hundreds ppb concentration level. Anodes such as platinum(Pt), titanium(Ti). zircornium(Zr), titanium metal coated with iridium(Ti-Ir), and glassy carbon coated with mixed valence ruthenium(mv Ru) were tried to remove the THMs at different potentials. The best result was obtained on the Ti-Ir anode applied 9 volts DC. The electrode could effectively remove almost all the THM components from the stirring solution within about 1.5 hours. The glassy carbon electrode coated with mixed valence ruthenium showed excellent removing effect at the begining, but the maximum removing level was remained at 60% probably due to the destruction of the electrode surface. The concentration of chloroform, however, tends to be increased due to the electrode reaction producing the component at the condition.
An environmentally friendly, so-called green, high performance liquid chromatography method was developed and validated for the determination of trans, trans-muconic acid (t,t-MA) in human urine as a biomarker of benzene exposure. After urinary t,t-MA was extracted and enriched using solid-phase extraction, a MF-Ph1 SG80 ($150mm{\times}2.0mm$ I.D., 5 ${\mu}m$) column with a mobile phase of 10 mM $KH_2PO_4$ containing 0.1% $H_3PO_4$ was used for isocratic separation of t,t-MA with UV detection at 259 nm. The calibration curve was constructed in the range of 0.1-5.0 mg/L with good linearity ($r^2$=0.9992). The intra-day and inter-day precision (as RSD) were 0.9-8.5% and 3.1-4.5%, respectively. The average recovery ranged from 97.5% to 101.7%. The green sample preparation and separation with no organic solvents were successfully achieved. The validated method would be suitable for the routine biological monitoring of benzene exposure in the occupational settings.
Choi, Su Jeong;Hwang, In Sook;Cho, Tae Hee;Lee, Jae In;Lee, In Sook;Yook, Dong Hyun;Park, Won Hee;Kim, Moo Sang;Kim, Gun Hee
Journal of Food Hygiene and Safety
/
v.30
no.4
/
pp.366-371
/
2015
This work was conducted to apply the multi class pesticide multiresidue method for determining the use of hexaconazole in the agricultural products using GC-NPD. The multi class pesticide multiresidue method results were validated for the assay of hexaconazole by using linearity, accuracy, precision, limit of detection and quantitation. The linearity in the concentration ranged from 0.025 to 5.0 mg/L ($R^2$ > 0.999). Lettuce recoveries ranged from 89.42% to 94.15% with relative standard deviations below 7.78%, for spiking levels from 0.04 to 4.0 mg/kg. The limit of detection was 0.04 mg/kg, and the limit of quantitation was 0.11 mg/kg. The intra- and inter-day precisions were 2.42~3.49% and 4.90~7.78%, respectively. We suggested that the multi class pesticide multiresidue method for determining hexaconazole was highly accurate and reproducible, and it will be used as a routine analysis in agricultural products.
Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.
As generic health functional food items have been expanded, this research project has been conducted to prepare a scientific and systematic standardized analytical method of relevant food item and examine the suitability of the method for health/functional foods on sale. Total polyphenol was necessary for development and verification of standardized analytical method. The method exhibited high linearity in the tannic acid calibration curve ($r^2$ > 0.999) over concentrations of $5-50{\mu}g/mL$. The limits of detection and quantitation for tannic acid were $5{\mu}g/mL$ and $15{\mu}g/mL$, respectively, while tannic acid recovery was 102.3-112.4% with standard deviations of 0.8-3.2%. To verify the accuracy of the analytical method, the labeled amounts of purchased health functional foods were monitored. The recovery for tannic acid was 105.6% of the labeled amounts. Thus, the new method was suitable for all cases.
The purpose of this study was to utilize the results as a basic data of benzoic acids in animal products that didn't mention in the quality standard of National Veterinary Research and Quarantine Service (NVRQS) to solve the conflict of international trade and administration. Set-Pak method listed in the quality standard of NVRQS, faster than auto distillation methods with same recovery selected as a pre treatment for the determination of benzoic acid. The regression curve of benzoic acid with Sep-Pak method was linear with the $R^2$ value of 0.999 and the limit of detection (LOD) and limit of quantitation (LOQ) was 0.058 mg/kg and 0.176 mg/kg, respectively. The benzoic acid in the fermented milk was detected after the fermentation stage by addition of starter culture with the level of 2.28~10.48 mg/kg and 0~16.5 mg/kg in the commercial fermented milk products without detection by the addition of syrup. In case of cheese products, the benzoic acids level was influenced by the curd formation (Camembert cheese) and the quality of natural cheese (processed cheese), by the way, the benzoic acid level of commercial natural cheese was 0~4.2 mg/kg, processed cheese was 0~20.8 mg/kg, respectively. Based on this result, it may be possible to utilize as a basic data for the systematic control the level of natural benzoic acids in raw material, processing and final products of animal origin.
A method was developed for the determination of fructooligosaccharides and raffinose contents in infant formula. The samples were extracted and analyzed by liquid chromatography equipped with carbohydrate column and evaporative light scattering detector. The mobile phase used for the gradient mode was water-acetonitrile, at a flow rate of 1.0mL/min. The method showed a mean recovery of 95-99%, the relative standard deviation obtained in the precision study was 0.774-8.982%, the quantification and detection limits were 25-50mg/L.
This paper describes a simultaneous method for the determination of two aminoglycosides (neomycin and gentamicin) using solid phase extraction followed by liquid chromatograph-mass spectrometry. The extract was applied to an WCX and HLB solid phase extraction cartridge. The cartridges were washed with water and methanol, and analytes were eluted with TCA buffer-acetonitrile mixture. The aminoglycosides were separated by ion-pairing reversed phase mode prior to ESI-LC/MS. Under the conditions applied neomycin was almost separated from all the gentamicin compounds. No interfering peaks from endogenous compounds of matrix were noted at the elution position of the analytes. Recoveries of neomycin fortified at levels of 0.25, 0.5, 1.0 and 2.0 mg/kg seafood samples ranged from 92 to 115%. Recoveries of gentamycin fortified at levels of 0.05, 0.1, 0.2, 0.4 mg/kg seafood samples ranged from 99 to 116%. Method detection limits in four seafood sample matrices were between 0.002 and 0.033 mg/kg.
Zearalenone (ZEA) is an estrogenic mycotoxin mainly produced by Fusarium graminerum, a species which colonizes a wide variety of cereals, including wheat, barley and processed products. A survey of ZEA contamination was conducted on 141 dried confectioneries, 59 breads and rice cakes, 135 noodles and 101 other products, for a total of 432 commercial samples. Samples were analyzed by high performance liquid chromatography with fluorescence detection (HPLC-FLD) after immunoaffinity clean-up and was confirmed by liquid chromatography tandem mass spectrometry (LCMS/MS). The limits of detection and quantification were 2.0 and $6.0{\mu}g/kg$, respectively. The recovery ranged from 80.2% to 98.4% in the cereal based product. ZEA was detected in 38 samples (8.8% incidence), including 3 snack, 2 biscuit and 33 other cereal products. The ZEA contamination levels were in the range of $5.38-53.76{\mu}g/kg$. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected ZEA, and all 38 samples showing ZEA by HPLC-FLD were confirmed by LC-MS/MS.
Lee Chang-Hee;Bahn Kyeong-Nyeo;Cho Tae-Yong;Lee Ju-Yeon;Lee Young-Ja;Chae Gae Yong
Journal of Food Hygiene and Safety
/
v.20
no.4
/
pp.267-271
/
2005
Lecithin is a naturally occurring group of phospholipids found in nearly every living cell and has been widely used as the ingredient of functional foods. Lecithin has high content of phosphatidylcholine(PC), pharmaceutical material which promotes metabolism through the cell membrane. This study was carried out to improve the present inconvenient analytical method of PC in law for health & functional foods. The commodities used in this experiment, were two kinds of egg yolk and eight kinds of soybean lecithin functional foods. PC was separated with isocratic elution with hexane : isopropanol : D.W (30:60:8) through silica column (2.1$\times$150 mm) by HPLC with Evaporative Light-Scattering Detector (ELSD). The flow rate of the eluent was 0.5 ml/mim and infect volume was 10ul. The neubilizer temperature of detector was $60^{\circ}C$, drift tube temperature of that was $75^{\circ}C$ and gas flow was 30 psi. Quantification was carried out by external standardization. Limit of quantification was 0.15ppm. Lecithin contents of egg yolk and soybean Products were > $66\%$ and > $81\%$), respectively. Phosphatidylcholine contents of egg yolk and soybean products were > $74\%$ and > $18\%$, respectively.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.