• Title/Summary/Keyword: 검량선

Search Result 264, Processing Time 0.026 seconds

Studies on the anodic oxidation of some volatile organic halogen compounds(THM) (휘발성 할로겐 화합물(THM)의 양극 산화에 관한 연구)

  • Yoo, K.S.;Park, S.Y.;Yang, S.B.;Woo, S.B.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.264-273
    • /
    • 1997
  • Anodic oxidation reaction was applied to remove trihalomethanes in an aqueous solution. Each component was determined by using solid phase microextraction(SPME) fiber and GC-ECD. Anodic and cathodic compartments were separated in order to protect contaminants and connected by $KNO_3$-agar bridge. The calibration graphs of the 6 THM components were shown good linearlity from a few ppb up to a few hundreds ppb concentration level. Anodes such as platinum(Pt), titanium(Ti). zircornium(Zr), titanium metal coated with iridium(Ti-Ir), and glassy carbon coated with mixed valence ruthenium(mv Ru) were tried to remove the THMs at different potentials. The best result was obtained on the Ti-Ir anode applied 9 volts DC. The electrode could effectively remove almost all the THM components from the stirring solution within about 1.5 hours. The glassy carbon electrode coated with mixed valence ruthenium showed excellent removing effect at the begining, but the maximum removing level was remained at 60% probably due to the destruction of the electrode surface. The concentration of chloroform, however, tends to be increased due to the electrode reaction producing the component at the condition.

  • PDF

Environmentally friendly determination of urinary trans, trans-muconic acid for biological monitoring of benzene exposure by green high-performance liquid chromatography (소변 중 뮤콘산의 친환경 HPLC 분석방법을 이용한 벤젠 노출 생물학적 노출평가)

  • Yang, Dong-Hyug;Lee, Mi-Young;Won, Yong Lim
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.460-466
    • /
    • 2012
  • An environmentally friendly, so-called green, high performance liquid chromatography method was developed and validated for the determination of trans, trans-muconic acid (t,t-MA) in human urine as a biomarker of benzene exposure. After urinary t,t-MA was extracted and enriched using solid-phase extraction, a MF-Ph1 SG80 ($150mm{\times}2.0mm$ I.D., 5 ${\mu}m$) column with a mobile phase of 10 mM $KH_2PO_4$ containing 0.1% $H_3PO_4$ was used for isocratic separation of t,t-MA with UV detection at 259 nm. The calibration curve was constructed in the range of 0.1-5.0 mg/L with good linearity ($r^2$=0.9992). The intra-day and inter-day precision (as RSD) were 0.9-8.5% and 3.1-4.5%, respectively. The average recovery ranged from 97.5% to 101.7%. The green sample preparation and separation with no organic solvents were successfully achieved. The validated method would be suitable for the routine biological monitoring of benzene exposure in the occupational settings.

Analysis of Hexaconazole in Agricultural Products using Multi Class Pesticide Multiresidue Method (다종 농약 다성분 분석법을 이용한 농산물 중 hexaconzole 분석)

  • Choi, Su Jeong;Hwang, In Sook;Cho, Tae Hee;Lee, Jae In;Lee, In Sook;Yook, Dong Hyun;Park, Won Hee;Kim, Moo Sang;Kim, Gun Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.4
    • /
    • pp.366-371
    • /
    • 2015
  • This work was conducted to apply the multi class pesticide multiresidue method for determining the use of hexaconazole in the agricultural products using GC-NPD. The multi class pesticide multiresidue method results were validated for the assay of hexaconazole by using linearity, accuracy, precision, limit of detection and quantitation. The linearity in the concentration ranged from 0.025 to 5.0 mg/L ($R^2$ > 0.999). Lettuce recoveries ranged from 89.42% to 94.15% with relative standard deviations below 7.78%, for spiking levels from 0.04 to 4.0 mg/kg. The limit of detection was 0.04 mg/kg, and the limit of quantitation was 0.11 mg/kg. The intra- and inter-day precisions were 2.42~3.49% and 4.90~7.78%, respectively. We suggested that the multi class pesticide multiresidue method for determining hexaconazole was highly accurate and reproducible, and it will be used as a routine analysis in agricultural products.

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.

Standardization for Analysis Method of Total Polyphenol in Complex of Picao Preto (피카오프레토 등 복합물 중 총 폴리페놀 분석법 표준화)

  • Hu, Soojung;Kim, Ji-An;Moon, Myung-Hee;Lee, Sung-Hye;Yoon, Hae-Seong;Hong, Jin-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • As generic health functional food items have been expanded, this research project has been conducted to prepare a scientific and systematic standardized analytical method of relevant food item and examine the suitability of the method for health/functional foods on sale. Total polyphenol was necessary for development and verification of standardized analytical method. The method exhibited high linearity in the tannic acid calibration curve ($r^2$ > 0.999) over concentrations of $5-50{\mu}g/mL$. The limits of detection and quantitation for tannic acid were $5{\mu}g/mL$ and $15{\mu}g/mL$, respectively, while tannic acid recovery was 102.3-112.4% with standard deviations of 0.8-3.2%. To verify the accuracy of the analytical method, the labeled amounts of purchased health functional foods were monitored. The recovery for tannic acid was 105.6% of the labeled amounts. Thus, the new method was suitable for all cases.

Evaluation of Benzoic Acid Level of Fermented Dairy Products during Fermentation (발효과정에서 생성되는 발효유제품의 안식향산 함량 수준 평가)

  • Lim, Sang-Dong;Park, Mi-Sun;Kim, Kee-Sung;Yoo, Mi-Young
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.640-645
    • /
    • 2013
  • The purpose of this study was to utilize the results as a basic data of benzoic acids in animal products that didn't mention in the quality standard of National Veterinary Research and Quarantine Service (NVRQS) to solve the conflict of international trade and administration. Set-Pak method listed in the quality standard of NVRQS, faster than auto distillation methods with same recovery selected as a pre treatment for the determination of benzoic acid. The regression curve of benzoic acid with Sep-Pak method was linear with the $R^2$ value of 0.999 and the limit of detection (LOD) and limit of quantitation (LOQ) was 0.058 mg/kg and 0.176 mg/kg, respectively. The benzoic acid in the fermented milk was detected after the fermentation stage by addition of starter culture with the level of 2.28~10.48 mg/kg and 0~16.5 mg/kg in the commercial fermented milk products without detection by the addition of syrup. In case of cheese products, the benzoic acids level was influenced by the curd formation (Camembert cheese) and the quality of natural cheese (processed cheese), by the way, the benzoic acid level of commercial natural cheese was 0~4.2 mg/kg, processed cheese was 0~20.8 mg/kg, respectively. Based on this result, it may be possible to utilize as a basic data for the systematic control the level of natural benzoic acids in raw material, processing and final products of animal origin.

Determination of Fructooligosaccharides and Raffinose in Infant Formula by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSC를 이용한 조제분유 중 fructooligosaccharides 및 raffinose 분석)

  • Shin, Man-Sub;Park, Jae-Woo;Cho, Mi-Ran;Song, Sung-Ok;Kim, Chun-Sun;Choi, Chun-Bae;Lee, Seoung-Won;Lee, Ki-Woong;Chang, Chi-Hoon;Kwak, Byung-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.725-729
    • /
    • 2006
  • A method was developed for the determination of fructooligosaccharides and raffinose contents in infant formula. The samples were extracted and analyzed by liquid chromatography equipped with carbohydrate column and evaporative light scattering detector. The mobile phase used for the gradient mode was water-acetonitrile, at a flow rate of 1.0mL/min. The method showed a mean recovery of 95-99%, the relative standard deviation obtained in the precision study was 0.774-8.982%, the quantification and detection limits were 25-50mg/L.

Simultaneous Analytical Method for the Neomycin, Gentamicin Residues in Seafood (수산물 중 네오마이신, 겐타마이신 동시분석법 개발)

  • Hong, Young-Min;Lee, Seok-Ki;Kim, Hyoung-Ah;Hwang, Yu-Kyung
    • Journal of Applied Biological Chemistry
    • /
    • v.53 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • This paper describes a simultaneous method for the determination of two aminoglycosides (neomycin and gentamicin) using solid phase extraction followed by liquid chromatograph-mass spectrometry. The extract was applied to an WCX and HLB solid phase extraction cartridge. The cartridges were washed with water and methanol, and analytes were eluted with TCA buffer-acetonitrile mixture. The aminoglycosides were separated by ion-pairing reversed phase mode prior to ESI-LC/MS. Under the conditions applied neomycin was almost separated from all the gentamicin compounds. No interfering peaks from endogenous compounds of matrix were noted at the elution position of the analytes. Recoveries of neomycin fortified at levels of 0.25, 0.5, 1.0 and 2.0 mg/kg seafood samples ranged from 92 to 115%. Recoveries of gentamycin fortified at levels of 0.05, 0.1, 0.2, 0.4 mg/kg seafood samples ranged from 99 to 116%. Method detection limits in four seafood sample matrices were between 0.002 and 0.033 mg/kg.

Analysis of Zearalenone Contamination in Cereal-Based Products Using High Performance Liquid Chromatography-Fluorescence Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry (곡류가공품 중 제랄레논 오염도 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Choi, In-Sun;Shin, Choon-Shik;Kim, Jin-Hee;Jang, Young-Mi;Kim, Dong-Sul;Ahn, Dong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.224-229
    • /
    • 2011
  • Zearalenone (ZEA) is an estrogenic mycotoxin mainly produced by Fusarium graminerum, a species which colonizes a wide variety of cereals, including wheat, barley and processed products. A survey of ZEA contamination was conducted on 141 dried confectioneries, 59 breads and rice cakes, 135 noodles and 101 other products, for a total of 432 commercial samples. Samples were analyzed by high performance liquid chromatography with fluorescence detection (HPLC-FLD) after immunoaffinity clean-up and was confirmed by liquid chromatography tandem mass spectrometry (LCMS/MS). The limits of detection and quantification were 2.0 and $6.0{\mu}g/kg$, respectively. The recovery ranged from 80.2% to 98.4% in the cereal based product. ZEA was detected in 38 samples (8.8% incidence), including 3 snack, 2 biscuit and 33 other cereal products. The ZEA contamination levels were in the range of $5.38-53.76{\mu}g/kg$. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected ZEA, and all 38 samples showing ZEA by HPLC-FLD were confirmed by LC-MS/MS.

Determination of Phosphatidylcholine in Korea Functional Foods Containing Lecithins using HPLC with Evaporative Light-Scattering Detector (ELSD) (ELSD를 이용한 레시틴중의 포스파티딜콜린의 분석)

  • Lee Chang-Hee;Bahn Kyeong-Nyeo;Cho Tae-Yong;Lee Ju-Yeon;Lee Young-Ja;Chae Gae Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.267-271
    • /
    • 2005
  • Lecithin is a naturally occurring group of phospholipids found in nearly every living cell and has been widely used as the ingredient of functional foods. Lecithin has high content of phosphatidylcholine(PC), pharmaceutical material which promotes metabolism through the cell membrane. This study was carried out to improve the present inconvenient analytical method of PC in law for health & functional foods. The commodities used in this experiment, were two kinds of egg yolk and eight kinds of soybean lecithin functional foods. PC was separated with isocratic elution with hexane : isopropanol : D.W (30:60:8) through silica column (2.1$\times$150 mm) by HPLC with Evaporative Light-Scattering Detector (ELSD). The flow rate of the eluent was 0.5 ml/mim and infect volume was 10ul. The neubilizer temperature of detector was $60^{\circ}C$, drift tube temperature of that was $75^{\circ}C$ and gas flow was 30 psi. Quantification was carried out by external standardization. Limit of quantification was 0.15ppm. Lecithin contents of egg yolk and soybean Products were > $66\%$ and > $81\%$), respectively. Phosphatidylcholine contents of egg yolk and soybean products were > $74\%$ and > $18\%$, respectively.