• Title/Summary/Keyword: 건축자재

Search Result 586, Processing Time 0.029 seconds

Characteristics of Generated Fibrous/Particulate Matters from Asbestos-Containing Building Materials(ACBMs) (해체·제거 작업 시 석면함유 건축자재에서 발생되는 섬유 및 입자상 물질의 특성)

  • Choi, Sungwon;Jang, Kwang Myoung;Park, Kyung Hoon;Kim, Dae Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.184-193
    • /
    • 2015
  • Objectives: This study focused on three aspects: characterizing concentrations of airborne particles by size distributions and asbestos fibers generated by various building materials; analyzing the characteristics of fibers produced by each simulation and asbestos fibers released from ACBMs; and investigating correlations of airborne asbestos fibers and particles generated and association of particle and asbestos concentrations. Methods: We selected three ACBMs including an insulation board, cement asbestos slate and wallboard. We constructed 4 scenarios; a) crushing with a hammer; b) cutting with a industrial knife; c) brushing with a metal brush; and d) tightening & loosening with a hand drill. We implemented one simulation for 30 seconds followed by 30 seconds resting period. We repeated a total of 5 cycles for 5 minutes. Results: The highest concentration of particulate & fibrous matters was from crushing with a hammer in each scenario followed by brushing with a metal brush, cutting with a industrial knife, and tightening & loosening with a hand drill. For ACBMs studied, asbestos concentrations were highest from an insulation board followed by cement asbestos slate, and wallboard. No difference in terms of concentration was found between an insulation board and asbestos slate. Fibers with $5{\sim}20{\mu}m$ in length were included in 76~90% of total fibrous matters. The distribution of the straight form fibers was greater than that of the curl form. About 90% of $PM_{Total}$ released from ACBMs was consisted of $PM_{10}$ while only 10% of $PM_{Total}$ was $PM_{2.5}$. Particulate matters like $PM_{2.5}$ was significantly correlated with fibrous matters($R^2=0.81$). Conclusions: We found ACBMs can significantly release asbestos fibers as well as $PM_{2.5}$. Concentrations of asbestos generated by ACBMs were well correlated with $PM_{2.5}$.

The Remained Basis and the Locational Characteristics of Manufacturing in Chonnam Region (전남지역 제조업의 존립기반과 입지특성)

  • Kim, Jae-Chul
    • Journal of the Korean association of regional geographers
    • /
    • v.2 no.2
    • /
    • pp.19-36
    • /
    • 1996
  • This study is to examine the remained basis and the locational characteristics of manufacturing in Chonnam region. First, the locational characteristics of manufacturing in the peripheral region examined through theoretical discussions about manufacturing location. And the locational characteristics of the small and medium firms and large firms be studied as to understand the precedent characteristics of Chonnam region. Chonnam region have the precedent characteristics that the regional capital is not accumulated as Japen exploit agricultural products at a colonial period. And SOC, industry and technology are not developed as geographically Chonnam lesion turn aside the economics axis of Korea-Japen-America within a period of industrialization. Manufacturing firms have beer make up the traditional indigenous firms which base on local market, agriculture and marine products in Chonnam lesion. The characteristics of these firms mainly are food & drink, nonmetal industry that is composed of the small and medium sized firms. The industrial structure is changing to machinery, chemistry, electronics industry from food & drink, nonmetal industry. But these industry is making the simple products. In Chonnam region, these change of industrial structure was expanding to the inland or coast region from the neighhoring region of Kwangju metropolitan. The blanch factories of large enterprises that located in Chonnam region are not connected with small and medium sized firms. The small and medium sized firms are not developed. Because these large enterprises are the iron and steel industry or chemistry industry. So the large-manufacturing firms have characteristics of the capital intensive industry, and make up the monopolistic industrial space of fordist blanch factories.

  • PDF

A study on the Manufacture and Application of UV-Cured Anti-stain Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내오염 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1741-1746
    • /
    • 2010
  • This study is on development of UV-cured anti-stain coating compounds which have more improved anti-stain function to prevent a surface of PVC tile from stain. To make an anti-stain coating composition, water soluble antistatic agent made from ammonium(IV) salt, antistatic agents for acrylic and polyurethane were used. Their contents varied from 5 to 20wt% against quantities of resin in coating composition. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-stain, electric resistance, adhesive power, thickness of coating, and so on. Results showed that a coating composition added 15wt% of water soluble antistatic agent and coated with No.12 bar-coater had the optimum surface property in electric resistance($3.24{\times}10^9{\Omega}/cm^2$), anti-stain(ink Test, Dust Test) and adhesive power. We could also find electric resistance and anti-stain effect were improved as antistatic agent content increased. However, excessive addition of antistatic agents(over 20wt%) caused the migration.

Comparative Evaluation on the Corrosion Resistance of Galvalume and Galvanized Steel Pipe (갈바륨 강관과 용융아연도금 강관의 내식성 비교 평가)

  • Choe, In-Hye;Park, Jun-Mu;Lee, Chan-Sik;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.163-163
    • /
    • 2016
  • 아연계 도금 강판은 우수한 내식성을 가지며 특히 아연의 희생방식기구에 의해 철의 부식을 억제하므로 선박, 건축자재, 전자기기 및 자동차 등 다양한 분야에서 그 수요와 사용범위가 증가하고 있다. 또한 도금 조성비 변화 및 다양한 표면처리 방법을 통해 가혹한 환경에서의 우수한 내식성에 대한 연구가 활발히 진행되고 있다. 그 중 갈바륨(Galvalume)은 55%의 알루미늄(Al)과 45%의 아연(Zn)으로 되어 있으며, 아연의 장점인 희생방식성과 내알카리성, 알루미늄의 장점인 내구성과 내열성, 내산성을 이상적으로 결합시킨 알루미늄(Al)-아연(Zn) 고내식 합금용융도금강판이다. 본 연구에서는 갈바륨 소재를 여러 산업현장에서 강관 형태로 사용할 경우의 내식성을 파악하기 위해 갈바륨 강관과 기존에 사용되고 있는 용융도금재인 용융아연도금 강관을 비교하며 실험을 진행하였다. 냉간압연강관에 용융아연도금 약 $25{\mu}m$, 갈바륨 약 $20{\mu}m$ 두께로 제작된 강관을 사용하였으며 제작된 도금층 표면 모폴로지는 SEM을 통해 관찰하였고, XRD 분석을 통해 결정 구조를 확인하였다. 또한 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 자연침지 시험 및 3% NaCl 용액 중 전기화학적 양극분극 시험을 진행하여 평가하였다. 5% NaCl 환경에서의 염수분무 시험 결과 용융아연도금의 경우 단면에서는 90시간, 표면에서는 260시간 경과 후 적청이 발생하였다. 반면, 갈바륨의 경우에는 단면에서 210시간 경과 후에 적청이 발생하였고, 표면의 경우에는 900시간 이상에서도 적청이 발생하지 않았다. 이 결과를 통해 용융아연도금에 비해 갈바륨 도금의 내식성이 단면에서는 3배, 표면에서는 4~5배 이상 향상된 것으로 확인되었다. 또한 3% NaCl 용액 중 자연침지 시험 결과 용융아연도금 강관 표면은 24시간 경과 후 열화부를 중심으로 흑변하는 것을 확인할 수 있었으나 갈바륨의 경우에는 900시간 이상 실험이 진행되는 동안 No Scribe 및 Scribe 시편 모두 외관상 변화가 거의 없었다. 단면의 경우, 용융아연도금 시편은 900시간 이상 실험이 진행되는 동안 외관상 변화가 없었으며, 갈바륨 시편의 경우 300시간 경과 하면서 흰색의 아연 부식생성물이 나타났으나 900시간 이후로도 적청은 발생하지 않았다. 자연전위 측정결과 용융아연도금 및 갈바륨 시편 모두 유사한 전위거동을 나타냈지만 단면의 경우 갈바륨 시편이 용융아연도금에 비해 안정적인 거동을 보였다. 3% NaCl 용액 중 전기화학적 양극 분극 시험 결과 용융아연도금이 갈바륨에 비해 귀한 방향의 부식 전위 값을 나타냈으며, 부식 전류밀도도 용융아연도금이 갈바륨에 비해 더 높은 값을 나타내는 것을 확인할 수 있었다. 이상의 염수분무시험, 자연침지시험 및 전기화학적 양극분극시험을 통해 종합적으로 분석-고찰하여 보면, 그 부식이 진행되는 과정은 융융아연도금과 달리 갈바륨 도금의 경우가 다단계적인 부식 과정을 거치면서 우수한 내식 특성을 나타낸다는 것을 알 수 있었다. 즉, 갈바륨 도금은 그 도금 막에 분포된 합금상 원소 성분들이 상호 갈바닉(Galvanic) 작용하며 형성된 부식생성물이 수평적으로 자체 차단(Barrier) 역할을 하는 과정과 부분적 부식-회복 과정을 거치면서 다단계적으로 부식속도를 감소시키게 된다는 것을 확인 할 수 있었다.

  • PDF

Economic Analysis of a 5-Story RC OMRF Retrofitted with Modified Epoxy Mortar for Improving Seismic Performance (변성에폭시 모르터로 내진보강한 5층 철근콘크리트 보통모멘트골조의 경제성 분석)

  • Kang, Suk-Bong;Kwak, Jongman;Shin, Dongwoo;Son, Kiyoung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.207-215
    • /
    • 2014
  • As a reinforcement material for RC members, the modified epoxy mortar has been reported one of the superior materials since the material can improve the load capacity and the seismic performance of the RC members. However, there were few experimental studies and analytical research for improving seismic performance with the material. This study is to propose an effective reinforcement plan for RC Ordinary Moment Resisting Frame (OMRF) with the evaluation of seismic performance and economic analysis. For the objective, first, the load-deflection curve of a simple beam specimen was compared with the analytical results. Second, a 5-story RC OMRF structure was designed only for gravity load and the alternatives for seismic reinforcement were suggested. Third, pushover analysis was executed for evaluation of design coefficients and seismic performance of the structures. Finally, an effective reinforcement plan was suggested based on the results of quantity take-off and economic analysis. The findings of this study can be utilized as the basic data when the modified epoxy mortar is applied to practice for improving the seismic performance of RC members.

Isolation of Acinetobacter calcoaceticus BP-2 Capable of Degradation of Bisphenol A (Bisphenol A 분해균주 Acinetobacter calcoaceticus BP-2의 분리 및 bisphenol A 분해 특성)

  • Kwon, Gi-Seok;Kim, Dong-Geol;Lee, Jung-Bok;Shin, Kee-Sun;Kum, Eun-Joo;Sohn, Ho-Yong
    • Journal of Life Science
    • /
    • v.16 no.7 s.80
    • /
    • pp.1158-1163
    • /
    • 2006
  • Bisphenol A (BPA), 2,2-bis(4-hydroxyphenyl) propane, has been widely used as a monomer for production of epoxy resins and polycarbonate plastics, and final products of BPA include adhesives, protective coatings, paints, optical lens, building materials, compact disks and other electrical parts. Since BPA is a toxic chemical to elicit acute cell cytotoxicity and chronic endocrine disrupting activity, the degradation of BPA has been focused during last decades. To overcome the problem of photo-, and chemical-degradation of BPA, in this study, a bacterium that is able to biodegrade BPA, was isolated. The bacterium, isolated froln the soil of plastic factory, was identified as Acinetobacter calcoaceticus (strain BP-2) based on physiological and 16S rDNA sequencing analysis. A. calcoaceticus BP-2 was able to grow in the presence of $1140{\mu}g\;ml^{-1}$ BPA. Biodegradation experiments showed that BP-2 mineralized BPA via 4-hydroxybenzoic acid and 4-hydroxyacetophenone, and average degradation rate was $53.3{\mu}g\;ml^{-1}\;day^{-1}$ under optimal conditions (pH 7 and $30^{\circ}C$). In high density resting cell $(3.5g-dcw.1^{-1})$ experiments, the maximal degradation rate was increased to $89.7{\mu}g\;ml^{-1}\;h^{-1}$. Our results suggest that BP-2 has high potential as a catalyst for practical BPA bioremediation.

Evaluation of Hydration Heat of Mass Concrete with Capsulated Slurry PCM and FEM Study for Analyzing Thermal Crack (캡슐형 슬러리 PCM을 혼입한 매스콘크리트의 수화열 평가 및 온도균열 FEM 해석에 관한 연구)

  • Park, ChangGun;Kim, Bo-Hyun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.379-388
    • /
    • 2014
  • The purpose of this study is to investigate the effect of capsulated slurry phase change material (PCM) on the thermal crack in mass concrete by experimental work and FEM analysis. In this study, three conditions of samples were prepared for evaluating the level of hydration heat, i.e., a material condition, a cement paste condition and a concrete condition. Also, a compressive strength test was conducted for FEM inverse analysis. Based on the results of the experiment, exothermic function coefficients of concrete with encapsulated slurry PCM were deducted by the inverse analysis. After that, they applied to FEM analysis of the mass scale concrete structures. From the results of this experiment, $31^{\circ}C$ capsulated slurry PCM had no super cooling phenomenon in the material condition. In the cement condition, hydration heat decreased by 34.61J when PCM of 1g was mixed. In the concrete condition, PCM of 6% was deducted as the best level in hydration heat absorption. In FEM inverse analysis, rate coefficient of reaction gradually decreased when PCM mixing ratio increased. But, temperature-rise coefficient increased when PCM mixing ratio exceeded 6%. For the inversed exothermic function coefficients applying to large scale concrete structures, a thermal cracking index increased by 0.05 when PCM of 1% was mixed.

Experimental Study on the Stress Variation of Concrete Containing F-fiber Extracted from Waste FRP (폐 FRP로부터 분리한 F-섬유를 이용한 콘크리트 강도 특성 변화에 대한 실험적 연구)

  • Yoon, Koo Young;Park, Jong Won;Lee, Seung Hee
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.42-45
    • /
    • 2014
  • Even though to discard the waste FRP (Fiber-Reinforced Plastic) is urgent and problematic, the way to do it has not been efficient. In our project team the FRP have been splitted into some layers which have different physical properties; mat and roving layers. Among those, the roving layer woven like a basket by bundles of glass fibers has been cut into reusable fibers called 'F-fiber'. F-fiber is 1 mm or 3 mm in width and 3 cm in length. It is used in fiber-reinforced concrete (FRC) with 0.5%, 0.7%, 1.0%, or 1.5% of volume ratio. Produced FRC was tested in compressive, tensile, and bending stress in contrast to the without-fiber (standard) concrete and 0.1% polypropylene reinforced concrete (PP-FRC). The tensile and bending stresses are more or less those of PP-FRC. The compressive stress, however, is similar (with 3 mm F-fiber) to or lower (with 1 mm F-fiber) than that of standard concrete. Conclusively the usage of the waste FRC in concrete is advised to be limited to the one where the compressive stress is not much critical.

Formulation and Application of UV-Cured Hard Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 하드 코팅액의 제조 및 응용에 관한 연구)

  • Park, Bo-Ram;Yoon, Hyun-Jung;Zhao, Hong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2396-2401
    • /
    • 2009
  • This study is on development of UV-cured hard coating compounds which have more improved abrasion resistance than existing UV-cured urethane-acrylic resin, to prevent a surface of a widely used PVC tile as a constructive material from being scratched. To make a high abrasion resistant hard coating solution compared to UV-cured urethane-acrylic resin which has no abrasion resistance and been used for PVC tiles, we added powder substances of different abrasion resistant level, $Al_2O_3$(Al-160SG-3), $Al(OH)_3$(SH-8W), $SiO_2$(KS-5000), etc., to the resin, changing their contents from 10% to 30% against quantities of resin, and compounded it using Ring-Mill. After coating PVC tiles with the hard coating solution using bar-coating method that can adjust a thickness, we estimated some surface properties-abrasion resistance, pencil hardness, adhesive power, thickness of coating, and so on. As a result, a hard coating solution added 30% $Al_2O_3$ powder to the resin had the finest surface properties-the first grade in abrasion resistance, H in pencil hardness, 100% in adhesive power, and a hard coating solution which showed excellent solidity and abrasion resistance has smaller particle size, higher powder content, and thicker coating thickness.

A Study on the Detoxification of Chrysotile and the use of High-density Extruded Cement Panel Reinforcement Fibers (백석면의 무해 섬유화 처리 방법과 고밀도 압출성형 패널 활용 연구)

  • Jang, Kyong-Pil;Kim, Tae-Hyoung;Song, Tae-Hyeob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.223-228
    • /
    • 2021
  • The final disposal method for asbestos building materials is to be landfilled at a designated waste landfill in accordance with the Waste Management Act. However, it is difficult to secure a domestic designated waste landfill site to landfill the entire amount of asbestos waste, which is expected to emit more than 400,000 ton/year by 2044. In this study, a detoxification treatment was performed on a ceiling tex with a density of 1.0 to 1.2g/cm3 containing 3 to 7% of chrysotile, and it was used as a reinforcing fiber for extruded panels. It was confirmed that asbestos components were detoxified through the reaction process using 30% oxalic acid and carbon dioxide, and it was recognized that these detoxifying properties were maintained even after extrusion molding. However, it was found that milling to a fiber size of less than 1mm for complete detoxification of asbestos resulted in a decrease in reinforcing performance. Therefore, in the case of using detoxified asbestos fibers in the extrusion molding process, it is considered desirable to add fibers with a length of 5mm or more to improve the reinforcing performance.