• Title/Summary/Keyword: 건축물 에너지성능평가

Search Result 84, Processing Time 0.025 seconds

Seismic Performance Evaluation of Reinforced Concrete Frames Reinforced with Chevron Bracing System (역V형 가새로 보강된 RC 골조의 내진성능평가)

  • Ha, Heonjun;Oh, Keunyeong;Lee, Kangmin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.13-22
    • /
    • 2018
  • In this study, seismic performance of existing RC frames reinforced with steel chevron bracing systems was experimentally evaluated. For this purpose, the unreinforced base specimen and seismically reinforced specimens with steel chevron bracing systems were fabricated and tested. Both strength and stiffness of the reinforced specimens were targeted about 2-3 times larger than the base specimen. Test results showed that the stiffness, strength, and ductility of the reinforced specimens considerably improved than those of unreinforced base specimen. Therefore, the results from this study could offer the basic information on the developing design guideline for the seismic reinforcement of RC frames.

Evaluation of Seismic Performance on Shear Walls in Steel House (스틸하우스 전단벽체의 내진성능평가)

  • 이재석;이승은;홍건호;김원기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.65-72
    • /
    • 2002
  • This study estimates steel house shear wall's seismic performance depending on trend of seismic design. As a result at cyclic-test, the capability of energy dissipation about X1SPCH during this test is good enough. The capability of energy dissipation of X3SPCH and X4SPCH was better than that of X1SPCH. The X2SPCH which is similar to real X-braced shear wall has better seismic performance than shear wall braced with structural sheathing materials on pseudo-dynamic test.

A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility (2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구)

  • Kang, Jung-Hun;Kwak, Young-Kuhn;Noh, Seung-Uk;Park, Dae-Ho;Lee, Ju-Ho;Hong, Wan-Pyo;Hwang, In-Kyu;Park, Tong-So
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

Performance Evaluation of the Drift Control in Residential Tall Building Using the Dampers (제진장치를 적용한 초고층 주거형 건축물의 횡변위 제어 성능 평가)

  • Park, Ji-Hyeong;Kim, Tae-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.265-273
    • /
    • 2008
  • The problem controlling lateral drift by the wind and the earthquake is very important in high rise buildings. But, outrigger system, generally used for residential tall buildings in Korea, has weak points with the occupancy of special space, the difficult construction and the long duration of works. On the other hand, the damper reduces story drifts of building structure by absorbing vibration energy induced by the dynamic loads and the application of damper systems is relatively simple. Also, the lateral drift control system such as outrigger system may raise the wind vibration problem of serviceability like human comfort and this problem may need another vibration control devices. Accordingly, we analyze the effect of the drift control using various dampers to substitute for outrigger system as the efficient system in residential tall buildings.

An Experimental Study on the Structural Behavior of Steel Grid Shear Wall subjected to Axial Force and Cyclic Lateral Load (축력과 반복수평력을 받는 격자강판 내진보강벽의 구조거동에 관한 실험적 연구)

  • Park, Jung Woo;Sim, Ki Chul;Park, Jin Young;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.525-532
    • /
    • 2012
  • The recently constructed buildings are ensuring seismic safety with enhanced design criteria. But, the buildings unapplied enhanced design criteria are very weak. In this study, steel grid shear wall is proposed as a solution of seismic retrofit to ensure safety of the existing buildings for the earthquake. And the structural performance experiments were carried out under axial force and cyclic lateral loads. The two specimens were made of a reference RC frame and steel grid shear wall in-filled RC frame. The test setup configured with two dynamic actuators, for the axial force with a 500kN capacity actuator and for the cyclic lateral load applied with the 2,000kN actuator. Compared with control specimen, the strength, stiffness, ductility, energy dissipation capacity of the seismic retrofit structures is evaluated.

A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.

Structural Performance of Reinforced Concrete Shear Walls Partially Cutted for Opening (개구부 설치를 위해 인위적 손상을 가한 전단벽의 구조성능 평가)

  • Choi, Youn Cheul;Choi, Hyun Ki;Choi, Chang Sik;Lee, Li Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.77-86
    • /
    • 2007
  • The more demands on efficient utilization of resources, the more structural engineers prefer to select remodeling to improve old building's capacity. A series of four shear wall specimens were tested under constant axial stress and reversed cyclic lateral loading in order to evaluate the effect of the opening on the lower center of the wall induce by remodeling. Consequently, the existence of opening was verified to induce a different failure, which was caused by reduction of compression strut area formed on the wall to diagonal direction. Especially, the ultimate strength of the wall with an opening was revealed approximately 35% lower than that of the wall without an opening. And the similar results were appeared in characteristics of stiffness and energy dissipation capacity.

A Study on the Energy Level of Education Facilities in Green Building Certification Criteria (학교시설 친환경인증 사례를 통한 에너지 평가항목에 대한 연구)

  • Kwon, Young-Cheol;Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.688-694
    • /
    • 2009
  • With the increase in the demand for sustainable and environmentally-friendly development, Green Building Certification System came into force in 2002, Evaluation parts of Green Building Certification System are divided into land use and transportation, energy, ecological environment, and indoor environment. Alloted point for the part of energy is larger than other part, thus we can say that this part is very important to increase the green building performance. This study aims to analyze the present condition of design and construction for the part of energy in the certificated green school building. Total 40 certificated school buildings were selected and average scoring rate of each item was evaluated. Key particular to be considered were suggested to improve the item of energy consumption.

Decision Support Process Model for Energy Efficient Remodeling Projects focused on Building Envelope and Renewable-energy Systems (에너지절감형 리모델링을 위한 적정 대안 선정 프로세스 모델 - 건축물 외피 및 신재생에너지 시스템을 중심으로 -)

  • Shin, Young-su;Cho, Kyuman;Kim, Jae-youn
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.91-100
    • /
    • 2015
  • An increase in energy such as natural gas, coal, oil, has occurred to a large amounts of environment impact emissions, it is necessary to reduce in the construction industry for the energy consumption. To encourage remodeling project in developed countries of the majority, on the basis of this, remodeling project in the construction industry has grown to a large amount. Results of analysis of the research related to the advanced remodeling, analysis of the economic validity in accordance with the production and process and building elapsed years of selection alternative of remodeling there has been a problem that has not been properly reflected. In this study, a decision support model that can simultaneously choose the most cost-effective and energy-efficiency alternative. Developed process model, generates a "Remodeling Solution" that combines the renewable energy equipment and envelope system, energy performance evaluation of the application of international standards(ISO-13790, DIN V 18599), perform the economic evaluation through LCCA(Life Cycle Cost Analysis) technique, circulated evaluation and configured to output the optimal Remodeling Solution. The results of applying the model developed in the case, it was confirmed that it is possible to select a choice of cost-effective energy-saving alternative. Then, developed model through this study, it is expected to be able to help highly effective remodeling alternative to selecting by decision-makers.

배관 세척장치의 성능평가

  • 조정식
    • 월간 기계설비
    • /
    • s.119
    • /
    • pp.71-83
    • /
    • 2000
  • 점차 복잡해지고 있는 사회적 욕구를 만족시키기 위한 건물에서는 반드시 복잡한 설비가 요구되고 있고, 이러한 설비시스템 중에는 급수, 급탕 및 배수설비라고 하는 배관시스템이 없다면 기능유지에 막대한 지장을 초래할 것은 자명하다고 하겠다. 이러한 배관시스템에서는 항시 또는 일부 사용되어질 물이나 사용된 물이 흐르기 때문에 배관내부에 발생하는 스케일(scale)이나 슬라임(slime) 등은 피할 수 없는 사실인 것이다. 건축물 내에 설치된 각종 배관은 건물의 기능을 유지하고 보건위생과 직결되는 중요한 기능을 담당하고 있어 세척의 필요성이 매우 높음에도 불구하고 배관의 수명이 다할 때까지 거의 세척이 이루어지지 않고 사용되어 왔다. 이들 배관에 대한 세척은 배관의 수명연장과 관마찰 계수를 낮추어 급수의 수송동력을 절감할 수 있고, 난방관의 열전달 효과를 높여 에너지 절약 효과를 거두어 건물의 유지관리 비용 절감에 기여할 수 있음에도 적절한 세척공법이 개발되지 않고 있다. 이러한 관점에 맞추어 건물배관의 특성에 맞도록 고압 세척장치를 개발하고 이를 이용한 세척공법을 적용하고자 하였다. 즉, 배관 내에 압축공기를 주기적으로 분사하여 맥동현상이 일어나도록 하면서 기포를 발생시켜 기포가 관의 내벽에서 성장하여 파괴될 때 관내에 부착된 이물질을 제거할 수 있고, 또한 세척효과를 높이기 위하여 관의 벽면에 접촉하면서 배출되는 과정에서 이물질을 제거할 수 있도록 구조와 아울러 이들 장치를 이용한 세척방법의 적용성에 대해서 고찰하고자 한다.

  • PDF