A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change (기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구)

  • Kwon, Ki-Uk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.

건축물 에너지 소비량 성능평가 프로그램의 최근 기술동향

  • 윤종호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.4
    • /
    • pp.7-11
    • /
    • 2002
  • 최대부하 및 기간부하, 쾌적성능, 부분적 시스템 성능, 자연에너지 활용 시스템 등 건물의 종합적 에너지 성능을 평가하는 대표적 프로그램의 기술동향을 고찰한다.

  • PDF

Seismic Capacity Evaluation of Wood Structure Using Soil-Wall Test (흙벽 실험에 의한 목조 건축물의 내진성능 평가)

  • Kim, Hye-Won;Yang, Won-Jik;Oh, Sang-Hoon;Lee, Jung-Han;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.409-412
    • /
    • 2010
  • 본 연구는 목조 건축물 흙벽의 수평가력실험 결과를 이용한 내진성능 평가를 목적으로 한다. 흙벽 실험시험체는 기둥과 보 결합방식에 따라 민도리, 초익공, 장여방식으로 분류되고 벽체 형태에 따라 창문, 문, 전면 벽체, 인방 부재수 등으로 계획을 하였다. 12개 흙벽 시험체의 가력결과, 전면 벽체 시험체는 변위각 1/30에서 가장 큰 강성 저하율을 보이며 중인방과 수직재가 있는 벽체는 에너지 소산능력이 가장 큰 것으로 나타났다. 기존 연구로부터 목조 건축물 항복점 평가방법을 이용하여 등가탄소성 곡선으로 나타낸 전단내력은 민도리방식이 프레임과 전면 벽체일 경우 가장 크고, 전단응력은 벽체 개구율에 따라 다르게 나타났다. 실험결과로부터 적용 대상 건축물의 X, Y방향 구조성능을 산출하고 구조내진지표와 역량스펙트럼을 이용하여 내진성능 평가를 실시한 결과, 대상 목조 건축물은 내진성이 있음으로 평가되었다.

  • PDF

Sensitivity Analysis of Building Envelope of Non-Dwelling Buildings (비주거 건축물의 외피요소에 대한 민감도 분석)

  • Kim, Kyung-Ah;Park, Jin-Seo;Yu, Ki-Hyung;Moon, Hyeun-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • The ECO2 building energy simulation program is used on the assessment project for building energy certification of non-dwelling buildings in Korea. In the design of energy efficient buildings, it is beneficial to identify the most important design parameters in oder to more efficiently develop alternative design solutions or reach optimized design solutions. The sensitivity analyses will be used at a reasonable early stage of the building design process, where it is still possible to influence the most important design parameters. In this study, the sensitivity analysis is focused on building envelope parameters such as U-values, SHGC and Wall-window ration.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

A methodology for verification of energy saving performance of Zero Energy School (ZES) (Zero Energy School(ZES) 에너지절감 성과 검증을 위한 방법론 연구)

  • Lee, Hangju;Ahn, JongWook;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Domestic buildings account for 25% of national greenhouse gas emissions and 20% of energy consumption, so energy efficiency improvement of buildings is recognized as the main target of national energy demand management. To improve the energy efficiency of the building, policies are implemented by preparing "zero-energy building national roadmaps" and enhancing the efficiency of national energy demand management through early activation as a result of expansion of the mandatory zero-energy building. Also, there is a growing need to verify the performance of energy savings after the construction is completed. Therefore, methods for evaluating energy performance of buildings should be suggested. This paper aims to develop and present methods for verifying energy performance of Zero Energy School, which can be applied internationally, by visiting domestic schools on-site at the same time as international standards and guidance analysis.

A Performance Evaluation of Solar Mirror Sunlighting Systems (반사거울형 태양광 채광시스템의 성능 평가)

  • Lee, Beom-Seok;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.30-37
    • /
    • 2005
  • 태양광 채광시스템은 자연광의 유입이 어려운 공간에 주광을 유입하기 위하여 개발된 장치로써 에너지를 절약하고 인간의 쾌적성을 향상시키는 등 지속가능한 건축을 위해 도입 및 확대가 크게 기대 되는 장치이다. 이에 본 연구는 기존에 본 연구실에서 개발된 시스템의 문제점을 보완하고 개선하여 건축물 적용시의 채광성능을 평가하는데 연구목적이 있다. 본 시스템의 설치는 2004년 10월 25일 (주) 동아산전과의 공동작업으로 설치되었으며, 수원에 있는 K대학 공과대학 5층 옥상 파라펫에 설치하였다. 평가실험은 2005년 4월 5일 9시30분부터 15시30분까지 청천공 상태에서 실시하였고, 총32개의 측정점을 선정하여 주광조도비로 채광성능을 평가하였다. 실험결과, 반사거울을 설치 시 창이 있을 경우 실내의 주광조도비는 평균 20.3[%] 상승하였고 창을 제거할 경우 실내의 주광조도비는 평균 38.2[%]정도 상승하여 채광학적으로 유효한 것으로 분석되었다. 따라서 본 시스템은 건축물의 실내 및 옥외의 음영진 곳에서 유용하게 사용될 수 있음이 입증되었다.

  • PDF

Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System (지열 냉난방 시스템의 성능 및 경제성 평가)

  • Lim Hyo Jae;Song Yoon Seok;Kong Hyoung Jin;Park Seong Koo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.296-300
    • /
    • 2004
  • Performance evaluation and economic estimation were conducted on the water to water GSHP (Ground Source Heat Pump) installed in existing building. Ground heat exchanger was a closed vertical loop type and sized to be 5 boreholes and 100m depth per borehole. Operation efficiency of the system shows that, COP increased from 3.0 to 4.2 with entering water temperature in heating operation, however, COP decreased from 5.0 to 3.7 in cooling operation. Economic estimation was analyzed by LCC (Life Cycle Cost) method and it showed that GSHP could save 68% of cost compare to the conventional oil source. Thus, despite of the large amount of initial cost, GSHP has a economic advantage to the other energy sources.

ESCO 기술연구-1-슬래브축열 공조시스템

  • 정재훈
    • The Magazine for Energy Service Companies
    • /
    • s.54
    • /
    • pp.64-69
    • /
    • 2008
  • 야간의 잉여전력으로 열을 저장해두었다 주간에 이용하는 축열공조에는 50여년에 걸친 긴 역사가 있었다. 이 방식이 가지는 효용에 일찍부터 눈뜬 선각자들의 노력에도 불구하고 당초 보급은 늦어져 그다지 진전이 없었다고 한다. 이러한 정세가 일변한 것은 전력공급에 병목현상이 생겨 부하 평준화가 안정공급에 있어 필요불가결의 과제가 되었기 때문이다. 특히 공조는 피크성이 강한 수요이므로 공조용 전력을 야간으로 옮기는 작업의 이점이 큰 것은 당연하다. 비 수요시간대의 요금이 큰 폭으로 떨어짐으로써 수요자측에서 보아도 야간의 전력을 어떻게 활용할까하는 것은 매력적인 연구테마였다. 이리하여 축열공조가 관심을 불러 보급이 기도에 놓인 지 2O년 가까이 되었다. 처음에는 물을 사용한 축열이 대부분이었으나, 축열조 용량의 제약으로 얼음을 만들어 저장하는 빙축열방식이 도입되어 현재의 표준적인 축열방식이되었다. 그러나 빙축열에도 비용상의 문제가 있어 전면적인 보급에 이르기까지는 아직 연구의 여지가 더 남아있는 듯하다. 한편, 교토의정서의 발효 등에 의해 지구환경에 대한 관심이 높아지게 되었다. 이 같은 배경 속에 건물및 건축설비의 에너지절약 기술의 중요성이 대두되고, 특히 창 주변의 공조방식, 조광제어, 축열 공조시스템 등, 건물부하의 직접적인 저감과 전력부하 평준화에 의한 환경부하저감 및 운영비용의 저감을 목적으로 한 건물일체형 설비시스템을 적극적으로 도입하기에 이르렀다. 환경을 배려한 건축구조.설비시스템의 채택 사례가 증가하며 건축물 종합환경성능 평가시스템과 성능검증 등 건물설비의 평가.검증 수법도 연구되어 건물에 적합한 운용면에서의 사고가 중요함이 인식되었다. 이와 같이 건축구조와 설비시스템의 양면에서 에너지절약성 및 환경성, 쾌적성, 편리성의 추구가 적극적으로 도입되는 가운데, 슬래브축열시스템은 건축구조와 공조설비가 균형있게 융합됨으로써 초기비용의 삭감과 부하 평준화에 의한 경제성 향상, 복사에의한 실내환경의 향상 등의 효과를 기대할 수있는 시스템으로 추목받고 있다.