• 제목/요약/키워드: 건축공학

검색결과 3,347건 처리시간 0.027초

20℃ 조건에서 초지연제 혼입율 변화에 따른 응결지연 성능 변화 분석 (Analysis of Setting Delay Performance Change of Super Retarding Agent According to the Change of Mixing Rate at 20℃)

  • 임군수;한수환;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.127-128
    • /
    • 2020
  • This research is part of the research for unifying the mass concrete and utilizing the rate of super retarding agent. We analyzed the performance of super retarding agent 20℃ conditions. It was found that there was no deterioration in fluidity and air quality due to the change in the super retarding agent mixing rate. It was found that when super retarding agent was mixed up to 0.5 %, it was delayed for 22.3 hours at 20℃. Therefore in order to ensure the performance required at the site, the super retarding agent mixing rate must be determined by fully considering the situation at the site. In addition it will be analyzed that super retarding agent performance analysis at high temperature will be required in subsequent studies.

  • PDF

유기안료 농도를 이용한 동절기 초기동해 피해 콘크리트의 깊이 진단 (Diagnose of Impaired Depth due to Early Frost Damage of the Concrete Using Organic Pigment Concentration)

  • 최윤호;임군수;김상민;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.167-168
    • /
    • 2020
  • In this study, we attempted to present a method for diagnosing the depth of the early frost damage concrete using organic pigments under the cold weather. As a result, it is considered that the organic pigment did not penetrate into the voids of the concrete that had been damaged by the early frost damage and only the surface was adhered. Therefore, when fine particles that can be melted in water and pass through voids are used, it is analyzed that it can penetrate damaged part of the concrete.

  • PDF

주입 보수공법 적용시 콘크리트의 드릴링 가능 시기 고찰 (Decision of Optimum Drilling Time for the Injection Based Repair Methods of the Impaired Concrete)

  • 한수환;최윤호;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2020
  • In this study, optimum time of drilling for injection of repair material was determined through surface stripping and cracking investigation by drilling from the 1 days to the 3 days of the age for the specimens with ∅100 mm. No surface stripping and cracking occurred on the third day of age, and the compressive strength value was above 14 MPa, which resulted in the appropriate time for drilling on the third day of age.

  • PDF

기건양생에 따른 고강도 콘크리트의 크리프 평가 및 모델 검토 (Creep Evaluation and Model Review of High-Strength Concrete According to Dry Curing)

  • 황의철;김규용;손민재;서동균;이예찬;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.146-147
    • /
    • 2020
  • In this study, creep deformation characteristics of high strength concrete under dry curing conditions were investigated. It was confirmed that the creep coefficient decreases as the compressive strength of concrete increases. In addition, a modified proposal for calculating the ultimate creep factor of the ACI 209 model can be derived using the measured values.

  • PDF

혼합슬래그 잔골재를 사용한 모르타르의 유동성 및 강도특성 (Fluidity and Strength Characteristics of Mortar Using Blended Slag Fine Aggregate)

  • 오태규;김지환;배성호;이재인;노영환;최세진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.100-101
    • /
    • 2020
  • This study is part of the research for improving the performance of mortar and concrete using blended slag aggregate to develope economical and high quality replacement aggregate. The characteristics of the fluidity and strength of mortar using the blended slag, which replaced the blended slag aggregate by 0, 25, 50, 75, 100% for the aggregate volume, were compared and analyzed.

  • PDF

적산온도 기반의 무선센서 네트워크(CIMS)를 이용한 현장타설 슬래브 및 벽체 콘크리트의 압축강도 추정 (Prediction of Strength Development of the Slab and Wall Concrete at Jobsite Applying Wireless Sensor Network (CIMS) based on Maturity)

  • 김상민;신세준;서항구;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2020
  • In this study, the concrete compressive strength estimation system Concrete IoT Management System (hereinafter referred to as CIMS) was developed, and CIMS was applied to domestic field structure slabs and wall concrete to check whether CIMS is practically available and to estimate the accuracy of the initial strength estimation of concrete. As a result, it shows a very high correlation when the compressive strength of the specimen for structural management is compared with the estimated strength of CIMS in terms of integrated temperature, and it is expected to be gradually applied to domestic construction sites in the future.

  • PDF

적산온도 기반 무선센서 네트워크(CIMS)를 이용한 현장타설 콘크리트의 압축강도 추정 (Prediction of Strength Development of the Concrete at Jobsite Applying Wireless Sensor Network (CIMS) based on Maturity)

  • 김상민;신세준;서항구;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2020
  • In this study, by applying the concrete compressive strength estimation system Concrete IoT Management System (hereinafter referred to as CIMS) to the concrete slab concrete in the domestic field, the purpose of this study is to confirm the practical use of CIMS and to verify the accuracy of estimating the initial strength of concrete. As a result, it shows a high correlation when the compressive strength and CIMS estimated strength of the specimen for structural management are converted and compared with the integrated temperature. However, in order to determine a more accurate experimental constant, it is necessary to consider the results up to 28 days.

  • PDF

강섬유 종류에 따른 시멘트 복합체의 전기전도도 측정에 대한 실험적 연구 (An Experimental Study on the Measurement of Electrical Conductivity of Cementitious Composites According to the Type of Steel Fiber)

  • 이예찬;김규용;남정수;이상규;서동균;유하민
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.191-192
    • /
    • 2020
  • The purpose of this study is to measure the electrical conductivity of cementitious composites as an early step to obtain shielding performance by mixing various type of steel fiber into cementitious composites, the main building material of protection facility, to shield electromagnetic pulse (EMP) damage. Fiber such as conductors as amorphous metallic fiber, hooked steel fiber, and smooth steel fiber are mixed into cementitious composites to give electrical conductivity and measure the impedance of concrete using LCR meter. By doing this, the electrical conductivity of each type of steel fiber reinforced cementitious composites (FRCC) is compared.

  • PDF

폐유리 잔골재 대체율이 물시멘트비가 다른 모르타르의 역학적 특성 및 알칼리 -실리카 반응에 미치는 영향 - (Effect of the replacement rates of Waste Glass Fine Aggregate on the Mechanical Properties and Alkali - Silica Reaction of Mortars with different W/C Ratio -)

  • 유하민;김규용;남정수;손민재;사수이;이예찬
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.195-196
    • /
    • 2020
  • This study evaluated the mechanical properties and alkali silica reaction of mortar according to the mixing ratio of waste glass. As a result, as the mixing ratio of the waste glass increased, the compressive and flexible strength of the mortar decreased due to the slip of aggregate, and the alkali-silica reaction(ASR) increased. So, it is considered that research is needed to prevent slip and ASR of the waste glass aggregate in order to use the waste glass as a fine aggregate for concrete.

  • PDF

동절기 타설 콘크리트의 초기동해 피해부위와 건전부위 압축강도 발현 특성 비교 (Comparison of the Compressive Strength between Damaged Part due to Early Frost Damage and Sound Part of the Concrete in Winter)

  • 최윤호;김상민;박병주;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2020
  • The objective of the study is to investigate the compressive strength of damaged part by early frost damage and sound part of the concrete placed when exposed to a low temperature of -20℃ for 24 hours in normal concrete. Test results indicated that the compressive strength of damaged part was 14.5 MPa lower than that of sounf part due to early frost damage.

  • PDF