• Title/Summary/Keyword: 건전성 평가시스템

Search Result 226, Processing Time 0.026 seconds

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Development of Risk Prediction Index in Water Distribution System (상수관로 위험도 예측을 위한 평가 지표 개발)

  • Ye Ji Choi;Han Na Jung;Dong Woo Jang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.402-402
    • /
    • 2023
  • 상수관망은 충분한 양질의 수돗물을 공급하기 위한 사회기반 시설물이다. 상수관로의 노후화, 누수 등은 수도 사고 발생의 가능성을 증가시키고, 수돗물 안전성에 대한 신뢰도를 감소시킨다. 수돗물 공급 전 과정을 인공지능(AI), 정보통신기술(ICT)과 결합한 지능형 상수도관 예측 및 관리 시스템을 구축하여, 상수도 수질 사고를 조기에 감지하고 사전에 취약지점을 예측할 필요가 있다. 이를 위해서는 상수관로의 위험도를 평가하기 위한 체계적인 데이터와 기준이 필요하다. 본 연구에서는 상수관로의 위험도 예측모델을 개발하기 위해 상수관로 위험도와 관련된 평가 인자를 선정하고 분류하였으며, 각 인자의 명확한 기준을 제시하였다. 국내·외 상수도 위험도 평가 항목에 대한 자료를 비교 및 분석하였고, 전문가 자문을 통해 인자를 정립하여 상수관로 위험도 평가 지표를 개발하였다. 개발된 평가 지표의 현장 적용성과 실효성 검증을 위해 정량적인 데이터 확보가 가능하고 상태를 평가할 수 있는 대상 지역을 선정하였다. 문헌 자료의 평가항목들과 전문가 의견을 바탕으로 상수관로 위험도 평가 인자를 31개의 직접 인자와 5개의 간접 인자로 구분하였고, 인자별 평가 기준을 제시하였다. 직접 인자는 노후화 정도를 파악할 수 있는 노후도 평가 항목, 지역 특성을 반영한 토양 부식성 항목, 실시간으로 측정하여 결과를 제공하는 실시간 계측 항목, 직접적인 수질 결과를 제공하는 정수장 수질 항목, 상수관로의 건전성을 평가하는 자산관리 항목으로 분류하였다. 추후, 위험도 평가 운용을 위한 알고리즘을 개발하면 상수도 사고 위험에 대한 예방 및 대응 전략을 수립할 수 있을 것으로 기대된다.

  • PDF

Prognostics and Health Management for Battery Remaining Useful Life Prediction Based on Electrochemistry Model: A Tutorial (배터리 잔존 유효 수명 예측을 위한 전기화학 모델 기반 고장 예지 및 건전성 관리 기술)

  • Choi, Yohwan;Kim, Hongseok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.939-949
    • /
    • 2017
  • Prognostics and health management(PHM) is actively utilized by industry as an essential technology focusing on accurately monitoring the health state of a system and predicting the remaining useful life(RUL). An effective PHM is expected to reduce maintenance costs as well as improve safety of system by preventing failure in advance. With these advantages, PHM can be applied to the battery system which is a core element to provide electricity for devices with mobility, since battery faults could lead to operational downtime, performance degradation, and even catastrophic loss of human life by unexpected explosion due to non-linear characteristics of battery. In this paper we mainly review a recent progress on various models for predicting RUL of battery with high accuracy satisfying the given confidence interval level. Moreover, performance evaluation metrics for battery prognostics are presented in detail to show the strength of these metrics compared to the traditional ones used in the existing forecasting applications.

Computer-Aided Monitoring and Assessment System for Maintenance of Grand Bridges (대형교량의 유지관리를 위한 전산화 모니터링 및 분석평가시스템)

  • Cho, Hyo Nam;Lim, Jong Kwon;Min, Dae Hong;Park, Kyung Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.369-381
    • /
    • 1998
  • This paper is intended to show some new approaches and concepts for the development of system model and prototype software for computer-aided Monitoring and Assessment(M&A) of grand bridges. The system model that incorporates optimal strategies for M&A of grand bridges is suggested. Reliability models are developed and a reliability-based capacity rating method is established for the evaluation of the bridge safety and reliability based on the real responses measured from a series of field load tests. Based on the proposed models, an integrated prototype software is then developed for computer-aided M&A of grand bridges under the environment of the graphic user interface, which is successfully applied to the M&A of an existing cable-stayed bridge. It may be stated that the system model and prototype software developed in this paper can be utilized and implemented in the development of the computer-aided M&A system for cable-stayed and suspension bridges.

  • PDF

Development of Structure Dynamic Characteristics Analysis System Prototype using Image Processing Technique (영상처리기법을 이용한 구조물 동특성 분석 시스템 프로토타입 개발)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Jung-Hoon;Kim, Do-Keun;Yoon, Kwang-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.11-21
    • /
    • 2016
  • Recently, structure safety management techniques using cutting-edge technology(Displacement senor, sensor of acceleration) has emerged as an important issue owing to the aging of infrastructure such as bridge and building. In general, the structural monitoring system for structure safety management is based on IT technology and it is expensive to install. In this paper developed an image-based structure dynamic characteristic analysis system prototype to assess the damage of structure in a more cost-effective way than traditional structure health monitoring system. The inspector can take a video of buildings or other structures with digital camera or any other devices that is passible to take video, and then using NCC calculation for image processing technique to get natural frequency. This system is analysis of damage of the structure using a compare between the frequency response ratio and functions when problems are occurs send alarm to administrator. This system is easier to install and remove than previous monitoring sensor in economical way.

Integrated System Design of Stream Generator Tube and Chemistry Inspection Information for Nuclear Power Plant (원전 증기발생기 세관 및 수질 검사정보 통합시스템 설계)

  • 신진호;이봉재
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.271-273
    • /
    • 2002
  • 증기발생기(SG : Steam Generator)는 다수의 세관으로 구성되어 원자로에서 발생한 열을 이용하여 발전기 터빈을 구동시키는 원동력인 증기를 생성해 주는 기능을 하는 원자력발전소의 핵심 설비이다. 증기발생기 세관의 건전성을 확보하기 위해 매주기 계획예방정비, 즉 가동중 검사마다 정기적인 와전류 검사를 수행하고, 검사결과에 따라 전열관 보수 등과 같은 제반 조치를 취하고 있다. 현재 검사데이터 DB 구축은 일부 발전소에 개발되어 운영 중에 있고, 세관 DB와는 별도로 통계정보만을 관리하는 증기발생기 성능관리시스템이 운영되고 있으며, 또한 각 발전소마다 수질을 계측하여 수화학 성분을 감시하는 수질관리시스템이 운용되고 있다. 이러한 이원화된 DB 및 시스템을 통합하고 연계하여 전 원전의 증기발생기를 종합적으로 관리 할 수 있는 시스템의 필요성이 대두되었다. 따라서 본 논문에서는 현장에 보관되어 있는 모든 세관 검사데이터를 취득하여 대용량 데이터베이스를 설계 및 구축하고 이기종의 분산된 수질관리시스템 DB를 연계하여, 증기발생기의 설계/제작부터 검사결과 Mapping, 추이 분석을 통한 수명 평가에 이르는 전 과정을 통합 관리할 수 있는 시스템을 설계하고 그 구현방안을 제시한다.

  • PDF

Development of Inspection and Diagnosis System for Safety and Maintenance in Tunnel (터널 유지관리를 위한 안전진단시스템 개발에 관한 연구)

  • Kim, Young-Geun;Baek, Ki-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Recently, as tunnel structure is getting old, many deformations and defects have been occurred. As tunnel has the characteristics of underground structure, the estimation of the cause of deformation is very difficult. Then, it is necessary to investigate the state of tunnel lining and to estimate the deformation cause and safety for tunnel. In this study, inspection and diagnosis system for effective maintenance in tunnel was researched. Firstly, non-destructive techniques such as GPR (ground penetrating radar), impact echo test, and infrared thermal techniques were applied to tunnel lining inspection. Tunnel lining analysis system was developed to analyze the stability of tunnel. And, tunnel soundness evaluation system was developed to find the probable causes and indicate the method for repair and reinforcement for tunnel.

  • PDF

대형 사회기반시설물의 스마트 건전성 평가기술

  • 윤정방;이진학;김정태
    • Journal of the KSME
    • /
    • v.44 no.6
    • /
    • pp.59-67
    • /
    • 2004
  • 최근 교량 및 발전구조물, 고층빌딩과 같은 대형 사회기반시설물의 유지관리를 위한 스마트 계측 및 모니터링 기술에 관한 관심과 연구개발 및 적용사례가 증가하고 있다. 특히 국내에서는 과거 '한강의 기적'이라 일컬어지는 초고속 경제성장과정에서 교량, 터널, 항만, 공항, 발전소, 댐 등 대형 사회기반시설물의 건설이 급증하였으나, 설계 당시에 고려되지 못하였던 각종 하중 조건과 환경 요인으로 인해 구조 건전성(structural integrity)의 저하가 일어나고 있다. 또한 최근 도서생활권의 향상 및 물류비용의 개선, 고속전철사업 등으로 인한 장대 교량의 건설, 효율적 국토이용을 위한 초고층빌딩의 건설, 석유자원의 고갈에 대비한 다양한 형태의 발전구조물의 건설 등이 증가하고 있으며, 이들 사회기반시설물의 유지관리를 위한 스마트 계측 및 모니터링 시스템이 더욱 중요해지고 있다. (중략)

  • PDF

Structural Safety Evaluation of Electro-Optical Camera Controller Box of CAS500 Satellite under Launch Environments (발사환경에 대한 차세대 중형위성 전자광학 카메라 제어용 전장품의 구조건전성 평가)

  • Lee, Myeong-Jae;Kim, Hyun-Soo;Lee, Duk-Kyu;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.98-105
    • /
    • 2018
  • The satellite is exposed to various launch environments such as random vibrations and shock. Accordingly, structural design of electronic equipment mounted on satellite must meet reliability requirements at the box level. In addition, it is essential to secure the reliability of the solder joint applied to electronic equipment. In this paper, we performed a modal and quasi-static analysis for the purpose of satisfaction of the design requirements of the CCB (Camera Controller Box) present on the 500 kg-class compact advanced satellite (CAS500). In addition, structural safety of electronic components was verified by the Steinberg's method and random equivalent static analysis.

Local Government Fiscal Consolidation Measures-Focusing on Cheonan- (지방정부 재정건전화 방안-천안시를 중심으로-)

  • Park, Jong Gwan
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.112-123
    • /
    • 2014
  • This Study aims to establish better sound fiscal plan by investigating perception of local government officials. Local government fiscal consolidation is affected by a combination of factors, including social, economic, demographic, political financial health of local governments. We derived the financial situation of the government-related indicators, financial health-related indicators, the indicators to improve the financial health on the basis of this study are an existing discussion. To ensure the financial soundness of the Cheonan, it is necessary to increase the efficiency of financial management including financial monitoring and control devices provided the locals, investment screening analysis system to enable it. In addition, fiscal controls should be strengthened in order to effectively autonomous government debt management. You must cuts expense of local government to prepare for expansion of local government finance, it is necessary to realize that the fee rates. It should be made through a blend of autonomy and control in the central government, network of local government and the development of local financial operations. You should also to be distributed to the residents welfare and community development funds are invested substantially to establish a systematic planning, resource allocation, evaluation, and reflux system.