• Title/Summary/Keyword: 건식 $CO_2$ 포집

Search Result 28, Processing Time 0.028 seconds

Deactivation causes of dry sorbents for post-combustion CO2 capture (연소 후 이산화탄소 포집용 흡수제의 비활성화 원인 규명)

  • Cho, Min Sun;Chae, Ho Jin;Lee, Soo Chool;Jo, Seong Bin;Kim, Tae young;Lee, Chul Ho;Baek, Jeom-In;Kim, Jae Chang
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.253-258
    • /
    • 2019
  • Several materials are used to design the sorbents applied in a fast-fluidized bed process for post-combustion $CO_2$ capture. In this study, $K_2CO_3$-based dry sorbent (KMC) was prepared by using Micro-cell C (MCC), one of the materials used to design the sorbent, and then its $CO_2$ sorption and regeneration properties were evaluated. KMC sorbent showed a low $CO_2$ capture capacity of 21.6 mg $CO_2/g$ sorbent, which is about 22% of the theoretical value (95.4 mg $CO_2/g$ sorbent) even at 1 cycle, and showed a low $CO_2$ capture capacity of 13.7 mg $CO_2/g$ sorbent at 5 cycles. It was confirmed that the KMC sorbent was deactivated due to the formation of a $K_2Ca$ $(CO_3)_2$ phase, resulting from the reaction of the $K_2CO_3$ with the Ca component contained in the MCC. In order to solve the deactivation of sorbent, and KM8 sorbent was prepared by adding the process of calcining the MCC at $850^{\circ}C$. The KM8 sorbent showed a high $CO_2$ capture capacity of 95.2 mg $CO_2/g$ sorbent and excellent regeneration property. Thus, it was confirmed that the deactivation of the sorbent could be solved by adding the calcining step to remove the side reaction causing material.

Characterization of dry sorbents for $CO_2$ separation from MSW incineration flue gas (도시생활폐기물 소각장에서 배출되는 이산화탄소 포집용 건식 흡착제 연구)

  • Kim, Byung-Soon;Lee, Ju-Yeol;Kim, Shin-Do
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.318-324
    • /
    • 2010
  • In this study, commercial pellet type sorbents for the collection of $CO_2$ from a local municipal waste incinerator were prepared and characterized in terms of adsorption efficiency by varying the operating conditions of a field process. The concentration of $CO_2$ in the flue gas ranged from 8 to 10%, which entered the test packed bed. As a result of this experiment, the sorbent procured from A-company, which is mainly composed of calcium compounds, showed the highest adsorption efficiency. The regeneration efficiency was fairly low, however. It also was found that based on adsorption breakthrough time, the relatively low flow rate of 10 LPM into the bed allowed higher collection efficiency. The higher flow rate of 40 LPM, on the other hand, tended to decrease the retention of the adsorption.

Heat Integration and Economic Analysis of Dry Flue Gas Recirculation in a 500 MWe Oxy-coal Circulating Fluidized-bed (CFB) Power Plant with Ultra-supercritical Steam Cycle (순환 유동층 보일러와 초초임계 증기 사이클을 이용한 500 MWe급 순산소 화력발전소의 건식 재순환 흐름의 열 교환 및 경제성 분석)

  • Kim, Semie;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • This study presented techno-economic analysis of a 500 MWe oxy-coal power plant with CO2 capture. The power plant included a circulating fluidized-bed (CFB), ultra-supercritical steam turbine, flue gas conditioning (FGC), air separation unit (ASU), and CO2 processing unit (CPU). The dry flue gas recirculation (FGR) was used to control the combustion temperature of CFB. One FGR heat exchanger, one heat exchanger for N2 stream exiting ASU, and a heat recovery from CPU compressor were considered to enhance heat efficiency. The decrease in the temperature difference (ΔT) of the FGR heat exchanger that means the increase in heat recovery from flue gas enhanced the electricity and exergy efficiencies. The annual cost including the FGR heat exchanger and FGC cooling water was minimized at ΔT = 10 ℃, where the electricity efficiency, total capital cost, total production cost, and return on investment were 39%, 1371 M$, 90 M$, and 7%/y, respectively.

A Study on the Separation and Recovery of Useful Metallic Elements(Zn, Pb) from the 2nd Dust in Refining of Crude-Zinc Oxide (조산화아연의 정제과정에서 발생된 2차분진으로부터 유용금속원소(Zn, Pb)의 분리회수에 관한 연구)

  • Yoon, Jae-hong;Yoon, Chi-hyun
    • Resources Recycling
    • /
    • v.30 no.1
    • /
    • pp.66-76
    • /
    • 2021
  • Electric arc furnace dust (EAFD) contains compounds, such as oxides and chlorides, including large quantities of Zn, Pb and Fe. An efficient and stable method for the extraction of metal elements from EAFD is the Rotary Kiln Process. This method is used to recover Zn in the form of crude ZnO (approximately 60%) via the addition of a reducing agent (coke, anthracite) and limestone (for basicity control) to EAFD. This process is commonly used in industry as well as in research and development. Currently, this method is used in many Korean commercial plants, producing approximately 150,000 tons of Crude ZnO per year. The majority of Zn is found in crude ZnO (approximately 76%). In addition components such as Pb, Cd, Sn, In, Fe, Cl, and F are present as oxides, chlorides, and alkaline compounds. This elements have an adverse effect on the zinc smelting process. Therefore, a refining process that eliminates these impurities is essential. In this study, we developed a process technology that efficiently separates Zn and Pb from byproducts (mainly chlorides). A bag filter was used to collect Zn and Pb generated during the dry purification process of crude ZnO. Pure components were recovered as metals or metal carbonate.

Operational Characteristics of a Dry Electrostatic Precipitator for Removal of Particles from Oxy Fuel Combustion (순산소 연소 배출 입자 제거용 건식 전기집진장치 운전 특성)

  • Kim, Hak-Joon;Han, Bang-Woo;Oh, Won-Seok;Hwang, Gyu-Dong;Kim, Yong-Jin;Hong, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • In a test duct with closed configuration, particle removal performance of an edge-plate type electrostatic precipitator (ESP) was evaluated at a high flow rate in $CO_2$ rich environments by changing gap distances between collection plates, concentrations of $CO_2$, particle sizes, types of electrodes, and types of power supplies. At the same experimental conditions, collection efficiency of particles with the mean particle size, 300 nm, decreased as the gap distance and $CO_2$ concentration increased because of low electrostatic force and low discharged current. In addition, as the particle size increased, the efficiency increased because of high charging rate of the large particles. With the electrode type which has higher surface area of a discharging plate and with the power supply which applied 25 kHz-pulsed DC voltages, the removal efficiency was high even in rich $CO_2$ condition due to high electrostatic force at the same power consumption.

Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process (벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가)

  • Kim, Jae-Young;Lim, Ho;Woo, Je Min;Jo, Sung-Ho;Moon, Jong-Ho;Lee, Seung-Yong;Lee, Hyojin;Yi, Chang-Keun;Lee, Jong-Seop;Min, Byoung-Moo;Park, Young Cheol
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.419-425
    • /
    • 2017
  • In this study, the performance characteristics of the K-based sorbents (KEP-CO2P2, KEPCO RI, Korea) has been studied in relation with the heat exchanger structure and shape in a mixing zone of the carbonator in the bench-scale dry $CO_2$ capture process. Two types of heat exchangers (different structure and shape) were used in the carbonator as CASE 1 and CASE 2, in which the experiment has been continuously performed under the same operating conditions. During the continuous operation, working temperature of carbonator was 75 to $80^{\circ}C$, that of regenerator was 190 to $200^{\circ}C$, and $CO_2$ inlet concentration of the feed gas was 12 to 14 vol%. Especially, to compare the dynamic sorption capacity of sorbents, the differential pressure of the mixing zone in the carbonator was maintained around 400 to 500 mm $H_2O$. Also, solid samples from the carbonator and the regenerator were collected and weight variation of those samples was evaluated by TGA. The $CO_2$ removal efficiency and the dynamic sorption capacity were 64.3% and 2.40 wt%, respectively for CASE 1 while they were 81.0% and 4.66 wt%, respectively for CASE 2. Also, the dynamic sorption capacity of the sorbent in CASE 1 and CASE 2 was 2.51 wt% and 4.89 wt%, respectively, based on the weight loss of the TGA measurement results. Therefore, It was concluded that there could be a difference in the performance characteristics of the same sorbents according to the structure and type of heat exchanger inserted in the carbonator under the same operating conditions.

Hydrodynamic Characteristics of Absorbent and Catalyst for Pre-combustion CO2 Capture (연소 전 이산화탄소 회수를 위한 흡수제 및 촉매의 수력학적 특성)

  • Ryu, Ho-Jung;Yoon, Joo-Young;Lee, Dong-Ho;Shun, Dowon;Park, Jaehyeon;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2013
  • To develop SEWGS (sorption enhanced water gas shift) system using dry $CO_2$ absorbent for pre-combustion $CO_2$ capture, hydrodynamic characteristics of $CO_2$ absorbents were measured and investigated. The minimum fluidization velocity of $CO_2$ absorbent was measured and the effects of the operating conditions were investigated to operate the system at bubbling fluidized bed condition. The minimum fluidization velocity decreased as pressure and temperature increased. Moreover, the minimum fluidization velocity decreased as column diameter increased. The effects of operating conditions on the solid circulation rate were measured and investigated to select appropriate operating conditions for continuous $CO_2$ capture and regeneration. The measured solid circulation rates were ranged between 10 and 65 kg/h and increased as the solid injection velocity, gas velocity in the regeneration reactor, and solid height increased.

Effect of Pressure on HCl Absorption Behaviors of a K-based Absorbent in the Fixed Bed Reactor (고정층 반응기에서 K-계열 흡수제의 압력에 따른 HCl 흡수 거동 연구)

  • Kim, Jae-Young;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Baek, Jeom-In;Park, Yeong Seong;Moon, Jong-Ho
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.165-172
    • /
    • 2013
  • In this study, the hydrogen chloride removal using K-based dry sorbents ($K_2CO_3/Al_2O_3$, KEPRI, Korea) was studied with varying the pressure in a fixed bed reactor (15 cm tall bed with 0.5 cm I.d.). Working temperature was $400^{\circ}C$ and feed gas concentration was 750 ppm (HCl vol%, $N_2$ balance). The chloride sorption capacity of sorbent increases with increasing pressure (1, 5, 10, 15 and 20 bar). Also, after forming KCl crystal by reaction with $K_2CO_3$ and HCl, owing to the strong bonding energy, sorbent regeneration was practically impossible. Its optical, physical and chemical characterizations were evaluated by SEM, EDAX, BET, TGA and XRD. At $400^{\circ}C$ and 20 bar condition, working condition for the dehalogenation process after gasification, K-based dry sorbent showed high HCl sorption capacity and HCl/$N_2$ separation performances comparing with Ca-based and Mg-based dry sorbents.