• Title/Summary/Keyword: 건물 유형

Search Result 296, Processing Time 0.027 seconds

Contribution Rate of Plant Parts to Dry Matter Yields in Winter Forage Crops (사료용 맥류의 맥종별 건물수량에 대한 식물체 부위별 기여도)

  • Kwon, Young-Up;Park, Hyoung-Ho;Baek, Seong-Bum;Park, Kwang-Geun;Kim, Jung-Gon;Lee, Jae-Eun;Seo, Jong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.4
    • /
    • pp.292-298
    • /
    • 2010
  • This study aims to understand the contribution rate of plant parts on biomass in five winter forage crops including barley, wheat, oat, rye and triticale. In barley and oat, the major plant parts on dry matter yields were changed from culm to spike at 20 days after heading(DAH), but culm was very important part on biomass of rye, wheat and triticales until 30DAH. Wheat, rye and triticales showed same pattern in dry weight increase indicating that culm was main component of biomass from heading stage but spike became heavier after 30 DAR. Barley and oat were similar in dry weight increase where spike was the main components of biomass at 20 DAR. After heading stage the major biomass of most winter forage crops were dependent on the weight of culm and spike, while the contribution of leaves to plant biomass was lower as compared to culm and spike. Thus culm and spike were very important factors for improving the dry matter production of winter forage crops breeding and early maturing is also additively required under Korean climatic condition.

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

3D building modeling from airborne Lidar data by building model regularization (건물모델 정규화를 적용한 항공라이다의 3차원 건물 모델링)

  • Lee, Jeong Ho;Ga, Chill Ol;Kim, Yong Il;Lee, Byung Gil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.4
    • /
    • pp.353-362
    • /
    • 2012
  • 3D building modeling from airborne Lidar without model regularization may cause positional errors or topological inconsistency in building models. Regularization of 3D building models, on the other hand, restricts the types of models which can be reconstructed. To resolve these issues, this paper modelled 3D buildings from airborne Lidar by building model regularization which considers more various types of buildings. Building points are first segmented into roof planes by clustering in feature space and segmentation in object space. Then, 3D building models are reconstructed by consecutive adjustment of planes, lines, and points to satisfy parallelism, symmetry, and consistency between model components. The experimental results demonstrated that the method could make more various types of 3d building models with regularity. The effects of regularization on the positional accuracies of models were also analyzed quantitatively.

A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types (냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구)

  • Lee, Kangbae;Park, Sungho;Lee, Hui-Won;Lee, Seung-Jae;Lee, Seung-hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.31-37
    • /
    • 2021
  • As the size of buildings increases due to urbanization due to the development of industry, the need to purify the air and maintain a comfortable indoor environment is also increasing. With the development of monitoring technology for refrigeration systems, it has become possible to manage the amount of electricity consumed in buildings. In particular, refrigeration systems account for about 40% of power consumption in commercial buildings. Therefore, in order to develop the refrigeration system failure diagnosis algorithm in this study, the purpose of this study was to understand the structure of the refrigeration system, collect and analyze data generated during the operation of the refrigeration system, and quickly detect and classify failure situations with various types and severity . In particular, in order to improve the classification accuracy of failure types that are difficult to classify, a three-step diagnosis and classification algorithm was developed and proposed. A model based on SVM and LGBM was presented as a classification model suitable for each stage after a number of experiments and hyper-parameter optimization process. In this study, the characteristics affecting failure were preserved as much as possible, and all failure types, including refrigerant-related failures, which had been difficult in previous studies, were derived with excellent results.

Building System Analysis and Integration: Case Study on Richards Medical Research Building (건물시스템의 분석과 통합 방법에 관한 연구: 리차즈 의학 연구소 건물의 사례분석을 중심으로)

  • Choi, Joon-Sung;Im, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1444-1451
    • /
    • 2011
  • The purpose of this paper is to provide an understanding of building systems and to propose methods of building system analysis and integration. Building components are classified into four major systems; structure, mechanical, envelope, and interior system. There are 11 combinations between major systems. Three integration modes(physical, visual, and functional integration) and 12 integration strategies are proposed. A case study of Richards Medical Research Buildings designed by Louis I. Kahn was conducted from the perspective of building system analysis and integration.

A Study on the Recognition of Modern Cultural Heritage Value of Japanese-style Building Groups Using Q Methodology - Focusing on Huam-dong, Seoul - (Q 방법론을 이용한 일본식 건물군의 근대문화유산 가치에 관한 인식 연구 - 서울시 후암동을 중심으로 -)

  • Park, Han-Sol;Sung, Jong-Sang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.6
    • /
    • pp.115-128
    • /
    • 2019
  • Huam-dong is a representative area from the Japanese colonial period and is the space where most Japanese-style buildings remain in Seoul. Interest in modern cultural heritage continues to increase, including the registration of cultural properties in 2001, building assets in 2015, and the registration of cultural property units in 2018. As the debate continues over the necessity of preserving cultural heritage that reminds us of the Japanese colonial, there is a need for research to grasp the perceptions of stakeholders along with the perceived value of such spaces. This study identified the subjective perception types of the stakeholders concerned with the Japanese-style building group in Huam-dong, analyzed characteristics by types, and debated the issues. For this purpose, Q methodology, which is a statistical technique for measuring human self-subjectivity and extracting common human perspectives, was used. A literature study on the values of Huam-dong and modern cultural heritage was conducted, and a Q questionnaire based on five aspects of modern cultural heritage values (historical, architectural, sociocultural, landscape, and economic) was applied. The results of the study depicted three types of cognition and showed different attitudes toward the Japanese building group. This study found a conflict comparing the perceptional differences between the types of cognition. This study is meaningful in that it provides an in-depth approach to the perspectives of the stakeholders concerned with the Japanese-style buildings clustered in central Seoul. It is also meant to present a theoretical framework that can be applied to the use area as sustainable cultural heritage through the establishment of preservation and utilization of Japanese-style areas and conflict resolution.

Effect of Mixture Types with Festulolium braunii (Festuca pratensis Huds. × Lolium multiflorum Lam.) on Dry Matter Yield and Quality (Festulolium braunii (Festuca pratensis Huds. × Lolium multiflorum Lam.)의 혼파유형이 목초의 건물수량과 품질에 미치는 영향)

  • Lee, In Duk;Lee, Hyung Suk
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.18 no.4
    • /
    • pp.311-316
    • /
    • 1998
  • This study was conducted to evaluate the dry matter yield and quality of mixture types with Festulolium braunii (Festuca pratensis Huds. ${\times}$ Lolium multiflorum Lam.) as a forage sources. The experiment was arranged in a randomized block design with three mixture types: (1) Festulolium braunii (seeding rate, FB 50%)+orchardgrass (OG 50%), (2) Festulolium braunii (FB 80%)+red clover(RC 20%), and (3) Festulolium braunii (FB 20%)+orchardgrass (OG 50%)+tall fescue(TF 20%)+white clover (WC 10%) and four replications. This study carried out from Sep. 1995 to May 1998 at Chungnam University. Throughout this experiment, the dry matter yields and forage quality were observed. The DM yield of FB+RC mixtures was higher than that of other mixture types, but there were no significant difference among mixture types. The FB+RC mixtures was higher than the other mixture types in the CP content(P<0.05). However, the NDF and ADF content of FB+RC mixtures were significantly lower than those of other mixture types(P<0.05). The CP and DDM yields of FB+RC mixtures were higher than those of other mixture types(P<0.05). In addition, the FB percentage of total herbage was ranged from 51% to 58% in all mixture types at the last cutting time in 1997. Based on the results mentioned above, it appears that FB has enough of possibility in mixture with other grasses, especially good mixed with RC.

  • PDF

Classification of Local Climate Zone by Using WUDAPT Protocol - A Case Study of Seoul, Korea - (WUDAPT Protocol을 활용한 Local Climate Zone 분류 - 서울특별시를 사례로 -)

  • Kim, Kwon;Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.131-142
    • /
    • 2017
  • This study aims to create a Local Climate Zone(LCZ) map of Seoul by using World Urban Database and Access Portal Tools(WUDAPT) protocol, and to analyze the characteristics of the Seoul LCZs. For this purpose, training samples of 17 LCZ types were collected by using Landsat images and Google Earth. LCZ Classification and Filtering were performed by SAGA GIS. An ArcGIS was used to analyze the characteristics of each LCZ type. The characteristics of the LCZ types were analyzed by focusing on building surface fraction ratio, impervious surface fraction ratio, pervious surface fraction ratio, building stories and air temperature. The results show that one filtering was found to be most appropriate. While Yangcheongu and Yeongdeungpogu with the higher annual and maximum mean air temperature than other areas have the higher rate of LCZ 3(compact low-rise) and LCZ 4(open high-rise), Jongnogu, Eunpyeonggu, Nowongu and Gwanakgu with the lower value have the higher rate of LCZ A(Dence trees). The values of building surface fraction ratio, impervious surface fraction ratio and building stories of each LCZ were included in the range of WUDAPT for most LCZs. However, the values of pervious surface fraction ratio were out of the range, in particular, in the LCZs 4~6 and 9~10. This study shows the usability and applicability of the WUDAPT methodology and its climate zone classification used in many countries as a basic data for the landscape planning and policy to improve the thermal environment in urban areas.

A Research on Air-tightness and Thermal performance of windows system classified by Windows type (에너지효율화를 위한 창호 유형별 기밀 및 단열성능에 관한 조사 연구)

  • Choi, Gyeong-Seok;Kang, Jae-Sik;Yang, Kwan-Seob;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.120-123
    • /
    • 2009
  • 건물에서 에너지손실이 큰 창호에 대해 최저소비효율기준 및 에너지소비효율 등급기준(안) 도입을 통해 지속가능한 고효율 창호의 보급 활성화 촉진과 관련 산업의 기술 및 산업력 향상을 적극적으로 유도할 필요가 있다. 이에 본 연구에서는 창호의 에너지 효율화를 위하여 고효율기자재(고기밀성 단열창호)로 인증받은 약 100여개 제품과 기타 제품에 대하여 창호 유형별 기밀 및 단열성능의 조사 분석을 통하여 창호 관련 제도 개정에 기초자료로 활용 에너지절약과 기후변화협약 관련 건물부문의 구체적 실천 대응방안으로 활용하고자 한다.

  • PDF

Analysis on the Risk of Explosive Terror in Domestic Buildings (국내 건물의 폭발물 테러 위험도 요인 분석)

  • Song, Jin-Young;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.73-80
    • /
    • 2012
  • According to the global status of terroristic acts occurred from 2002 to 2010, 10,431(nearly 52.2%) of 19,946 cases have happened by bomb blasts, and 10,431(nearly 52.2%) of weapons used for terrorism were explosive substances Therefore, this study analyzed the terrorism risks of buildings according to height through FEMA 455 - rapid visual screening. As a result, the higher the building is, the higher the terror risk gets. It shows that total risk increases proportionally to buildings's height. In case of buildings over 100 meter high, the total risk is most affected by threat items. According to the risk of explosion associated with the scenario analysis, buildings over 100 meter high have high risks of Internal-Explosive.